Tong-Bou Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tong-Bou Chang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Jhong-Wei Huang
National Taipei University of Technology
6 shared publicationsJer-Jia Sheu
Department of Mechanical Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan
2 shared publications- Jhong-Wei Huang
Department of Mechanical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, Taiwan
2 shared publications Tsung-Han Lin
Department of Mechanical Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan
2 shared publicationsBai-Heng Shiue
Department of Mechanical and Energy Engineering, National Chiayi University, Chiayi, Taiwan
1 shared publicationBao-Qiang Bei
1 shared publication
Latest Publications
- 20 May 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
In-cabin energy recovery ventilation for enhanced air quality and reduced air-conditioning energy consumption
Excessive carbon dioxide in vehicle cabins can impair driver judgment and compromise safety. Introducing fresh air into the cabin mitigates this problem but increases the cooling load and energy consumption of the air-conditioning system. To address this issue, this study proposes the use of an in-cabin energy recovery ventilation system that exchanges heat between the expelled cabin air and the incoming fresh air, thereby reducing the cooling load and energy consumption. The system is equipped with a high-efficiency filter that removes suspended particulates from the incoming fresh air, further improving the indoor air quality of the cabin. The performance of the ventilation system was evaluated using computational fluid dynamics simulations. With the system running at a low speed and five occupants within the cabin, the carbon dioxide concentration reduced from approximately 7600 to 3000 ppm within 30 min. Additionally, the number of suspended particles decreased by approximately half to 630 particles/cm 3 . At high speeds, the carbon dioxide concentration decreased to 2400 ppm after 30 min, and the suspended particle concentration decreased to approximately 530 particles/cm 3 . The corresponding net energy savings were estimated to be 79.6 and 110.3 W, respectively. The results demonstrate that the proposed system effectively improves the in-cabin air quality while simultaneously enhancing energy efficiency.
- 20 May 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
In-cabin energy recovery ventilation for enhanced air quality and reduced air-conditioning energy consumption
Excessive carbon dioxide in vehicle cabins can impair driver judgment and compromise safety. Introducing fresh air into the cabin mitigates this problem but increases the cooling load and energy consumption of the air-conditioning system. To address this issue, this study proposes the use of an in-cabin energy recovery ventilation system that exchanges heat between the expelled cabin air and the incoming fresh air, thereby reducing the cooling load and energy consumption. The system is equipped with a high-efficiency filter that removes suspended particulates from the incoming fresh air, further improving the indoor air quality of the cabin. The performance of the ventilation system was evaluated using computational fluid dynamics simulations. With the system running at a low speed and five occupants within the cabin, the carbon dioxide concentration reduced from approximately 7600 to 3000 ppm within 30 min. Additionally, the number of suspended particles decreased by approximately half to 630 particles/cm 3 . At high speeds, the carbon dioxide concentration decreased to 2400 ppm after 30 min, and the suspended particle concentration decreased to approximately 530 particles/cm 3 . The corresponding net energy savings were estimated to be 79.6 and 110.3 W, respectively. The results demonstrate that the proposed system effectively improves the in-cabin air quality while simultaneously enhancing energy efficiency.
- Open Access
- 15 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Design and experimental evaluation of multi-mode HVAC system with dehumidification heat pump capability for electric vehicles
- 15 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessDesign and experimental evaluation of multi-mode HVAC system with dehumidification heat pump capability for electric vehicles
- Open Access
- 14 October 2025
- Published by MDPI AG in Pollutants
- Vol. 5  (4) , 36
Effects of Different Ventilation Strategies on In-Cabin Air Quality During High-Speed Driving
When driving at highway speeds, the airtightness and ventilation mode of the cabin can significantly affect the in-cabin air quality. Accordingly, this study conducted on-road driving experiments along four highways in Tainan City, Taiwan, to examine the effects of different ventilation strategies and driving speeds on the concentrations of three pollutants (carbon dioxide (CO2), PM2.5, and PM10) in the cabin of a mid-size sedan. During the test, the vehicle will travel at a constant speed of 60, 70, 80, 90, 100, 110 and 120 km/h depending on the traffic conditions. When driving on the system interchanges, the vehicle speed was maintained at 40 and 50 km/h. Ventilation strategies are divided into fresh air mode and recirculation air mode. The results revealed that leakage ventilation at high speeds allowed more outdoor air to infiltrate the cabin. This reduced the CO2 concentration but slightly increased the particulate matter (PM) when the ventilation system was operated in the recirculation mode. The continuous use of the recirculation air mode for extended periods resulted in a potentially hazardous increase in the CO2 concentration. Thus, periodic switching to the fresh air mode is recommended to ensure that the in-cabin CO2 concentration remains below the ASHRAE threshold of 1000 ppm. In the fresh air mode, the PM2.5 and PM10 concentrations decreased as the vehicle speed increased. In the recirculation mode, the cabin filters maintained lower in-cabin PM levels than in the fresh-air mode. The experimental data were fitted using a curve-fitting technique to quantify the relationships between the vehicle speed and the in-cabin CO2, PM2.5, and PM10 concentrations under the two ventilation strategies. The findings of this study provide useful practical guidelines for optimizing the vehicle ventilation strategy to improve the in-cabin air quality and enhance occupant health and safety during highway driving.
- 14 October 2025
- Published by MDPI AG in Pollutants
- Vol. 5  (4) , 36
Open AccessEffects of Different Ventilation Strategies on In-Cabin Air Quality During High-Speed Driving
When driving at highway speeds, the airtightness and ventilation mode of the cabin can significantly affect the in-cabin air quality. Accordingly, this study conducted on-road driving experiments along four highways in Tainan City, Taiwan, to examine the effects of different ventilation strategies and driving speeds on the concentrations of three pollutants (carbon dioxide (CO2), PM2.5, and PM10) in the cabin of a mid-size sedan. During the test, the vehicle will travel at a constant speed of 60, 70, 80, 90, 100, 110 and 120 km/h depending on the traffic conditions. When driving on the system interchanges, the vehicle speed was maintained at 40 and 50 km/h. Ventilation strategies are divided into fresh air mode and recirculation air mode. The results revealed that leakage ventilation at high speeds allowed more outdoor air to infiltrate the cabin. This reduced the CO2 concentration but slightly increased the particulate matter (PM) when the ventilation system was operated in the recirculation mode. The continuous use of the recirculation air mode for extended periods resulted in a potentially hazardous increase in the CO2 concentration. Thus, periodic switching to the fresh air mode is recommended to ensure that the in-cabin CO2 concentration remains below the ASHRAE threshold of 1000 ppm. In the fresh air mode, the PM2.5 and PM10 concentrations decreased as the vehicle speed increased. In the recirculation mode, the cabin filters maintained lower in-cabin PM levels than in the fresh-air mode. The experimental data were fitted using a curve-fitting technique to quantify the relationships between the vehicle speed and the in-cabin CO2, PM2.5, and PM10 concentrations under the two ventilation strategies. The findings of this study provide useful practical guidelines for optimizing the vehicle ventilation strategy to improve the in-cabin air quality and enhance occupant health and safety during highway driving.
- Open Access
- 1 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15  (17) , 13182
Development of Energy-Saving Battery Pre-Cooling System for Electric Vehicles
The performance, lifetime, and safety of electric vehicle batteries are strongly dependent on their temperature. Consequently, effective and energy-saving battery cooling systems are required. This study proposes a secondary-loop liquid pre-cooling system which extracts heat energy from the battery and uses a fin-and-tube heat exchanger to dissipate this energy to the ambient surroundings. The liquid then passes through a chiller to complete the cooling loop. The air-conditioning system is also used to cool the battery only if the temperature of the cooling water exceeds the maximum permissible temperature. The cooling load of the air-conditioning system is thus greatly reduced. The feasibility of the proposed cooling system is demonstrated experimentally under four simulated seasonal environmental conditions, namely high summer (35 °C), mean summer (30 °C), spring and fall (20 °C), and winter (7 °C). The results show that the pre-cooling system can dissipate 1000 W of battery heat in high summer, 2000 W in low summer, 3167 W in spring and fall, and more than 4000 W in winter. In other words, the pre-cooling system greatly reduces the cooling load of the air-conditioning system, and hence significantly reduces its energy consumption.
- 1 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15  (17) , 13182
Open AccessDevelopment of Energy-Saving Battery Pre-Cooling System for Electric Vehicles
The performance, lifetime, and safety of electric vehicle batteries are strongly dependent on their temperature. Consequently, effective and energy-saving battery cooling systems are required. This study proposes a secondary-loop liquid pre-cooling system which extracts heat energy from the battery and uses a fin-and-tube heat exchanger to dissipate this energy to the ambient surroundings. The liquid then passes through a chiller to complete the cooling loop. The air-conditioning system is also used to cool the battery only if the temperature of the cooling water exceeds the maximum permissible temperature. The cooling load of the air-conditioning system is thus greatly reduced. The feasibility of the proposed cooling system is demonstrated experimentally under four simulated seasonal environmental conditions, namely high summer (35 °C), mean summer (30 °C), spring and fall (20 °C), and winter (7 °C). The results show that the pre-cooling system can dissipate 1000 W of battery heat in high summer, 2000 W in low summer, 3167 W in spring and fall, and more than 4000 W in winter. In other words, the pre-cooling system greatly reduces the cooling load of the air-conditioning system, and hence significantly reduces its energy consumption.
- Open Access
Air Conditioning Operation Strategies for Comfort and Indoor Air Quality in Taiwan’s Elementary Schools
The Executive Yuan in Taiwan plans to install air-conditioning (A/C) in all elementary schools within two years. However, besides the associated energy consumption and environmental issues, the use of A/C will inevitably result in the doors and windows of the classroom being closed, which will increase the accumulation of carbon dioxide (CO2) within the classroom. An excessive indoor CO2 concentration can result in reduced cognitive performance and an impaired learning efficiency. Therefore, the moderate introduction of external air into the classroom is essential to increase the air exchange rate (AER) and reduce the CO2 concentration level. Accordingly, the present study conducts a numerical investigation into the effects of various A/C operation strategies on the CO2 concentration within the classroom given different proportions of students remaining in the classroom during the recess. Overall, the results indicate that the optimal usage strategy is to operate the A/C over the full school day (08:00~15:50 p.m.) in conjunction with a mechanical ventilation system providing a fresh air exchange rate of 5 l/s for every person in the room. However, the use of a mechanical ventilation system inevitably incurs an additional hardware and energy consumption. Thus, an alternative recommendation is also proposed, in which the windows are opened and the air conditioner is turned off at every recess and during the lunchtime period. It is shown that the resulting CO2 concentration in the classroom is still consistent with the Taiwan Environmental Protection Administration (EPA) regulations and the thermal comfort of the students is achieved for more than three-quarters of the school day.
Open AccessAir Conditioning Operation Strategies for Comfort and Indoor Air Quality in Taiwan’s Elementary Schools
The Executive Yuan in Taiwan plans to install air-conditioning (A/C) in all elementary schools within two years. However, besides the associated energy consumption and environmental issues, the use of A/C will inevitably result in the doors and windows of the classroom being closed, which will increase the accumulation of carbon dioxide (CO2) within the classroom. An excessive indoor CO2 concentration can result in reduced cognitive performance and an impaired learning efficiency. Therefore, the moderate introduction of external air into the classroom is essential to increase the air exchange rate (AER) and reduce the CO2 concentration level. Accordingly, the present study conducts a numerical investigation into the effects of various A/C operation strategies on the CO2 concentration within the classroom given different proportions of students remaining in the classroom during the recess. Overall, the results indicate that the optimal usage strategy is to operate the A/C over the full school day (08:00~15:50 p.m.) in conjunction with a mechanical ventilation system providing a fresh air exchange rate of 5 l/s for every person in the room. However, the use of a mechanical ventilation system inevitably incurs an additional hardware and energy consumption. Thus, an alternative recommendation is also proposed, in which the windows are opened and the air conditioner is turned off at every recess and during the lunchtime period. It is shown that the resulting CO2 concentration in the classroom is still consistent with the Taiwan Environmental Protection Administration (EPA) regulations and the thermal comfort of the students is achieved for more than three-quarters of the school day.
- 16 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237  (6) , 2392-2402
An experimental method for evaluating vehicle cabin airtightness and ventilation performance
An experimental method is proposed for evaluating the airtightness of a vehicle cabin and the ventilation effects of three components of the vehicle ventilation system. The measurement results are used to derive a theoretical equation to predict the total air infiltration rate of the cabin as a function of the pressure difference between the cabin interior and exterior, respectively. The validity of the predictive equation is demonstrated by means of fan pressurization experiments performed with the vehicle air-conditioning system set in the fresh air mode. It is shown that the prediction results for the total ventilation rate deviate from the experimental results by less than 10%. The infiltration ventilation effect of natural diffusion in the vehicle cabin is measured using the CO2 tracer gas method. The air exchange rate (ACH) of the cabin is found to be 0.816 in the recirculation air mode and 3.554 in the fresh air mode.
- 16 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237  (6) , 2392-2402
An experimental method for evaluating vehicle cabin airtightness and ventilation performance
An experimental method is proposed for evaluating the airtightness of a vehicle cabin and the ventilation effects of three components of the vehicle ventilation system. The measurement results are used to derive a theoretical equation to predict the total air infiltration rate of the cabin as a function of the pressure difference between the cabin interior and exterior, respectively. The validity of the predictive equation is demonstrated by means of fan pressurization experiments performed with the vehicle air-conditioning system set in the fresh air mode. It is shown that the prediction results for the total ventilation rate deviate from the experimental results by less than 10%. The infiltration ventilation effect of natural diffusion in the vehicle cabin is measured using the CO2 tracer gas method. The air exchange rate (ACH) of the cabin is found to be 0.816 in the recirculation air mode and 3.554 in the fresh air mode.
- Open Access
- 19 January 2022
- Published by MDPI AG in Healthcare
- Vol. 10  (2) , 193
Ventilation Performance Evaluation of a Negative-Pressurized Isolation Room for Emergency Departments
Due to the emergence of COVID-19 becoming a significant pandemic worldwide, hospitals are expected to be capable and flexible in responding to the pandemic situation. Moreover, as frontline healthcare staff, emergency department (ED) staff have a high possibility of exposure risk to infectious airborne. The ED isolation room will possibly and effectively isolate the infected patient, therefore safekeeping frontline healthcare staff and controlling the outbreak. However, there is still limited knowledge available regarding isolation room facilities specifically for the emergency department. In this study, field measurement is conducted in an ED isolation room located in Taiwan. CFD simulation is employed to simulate and investigate the airflow and airborne contaminant distribution. Instead of high air-change rates (ACH) that purposes for dilution, this study proposes the arrangement of exhaust air grilles to improve the contaminant removal. The results reveal that the exhaust air grille placed behind the patient’s head is optimized to dilute airborne contaminants.
- 19 January 2022
- Published by MDPI AG in Healthcare
- Vol. 10  (2) , 193
Open AccessVentilation Performance Evaluation of a Negative-Pressurized Isolation Room for Emergency Departments
Due to the emergence of COVID-19 becoming a significant pandemic worldwide, hospitals are expected to be capable and flexible in responding to the pandemic situation. Moreover, as frontline healthcare staff, emergency department (ED) staff have a high possibility of exposure risk to infectious airborne. The ED isolation room will possibly and effectively isolate the infected patient, therefore safekeeping frontline healthcare staff and controlling the outbreak. However, there is still limited knowledge available regarding isolation room facilities specifically for the emergency department. In this study, field measurement is conducted in an ED isolation room located in Taiwan. CFD simulation is employed to simulate and investigate the airflow and airborne contaminant distribution. Instead of high air-change rates (ACH) that purposes for dilution, this study proposes the arrangement of exhaust air grilles to improve the contaminant removal. The results reveal that the exhaust air grille placed behind the patient’s head is optimized to dilute airborne contaminants.
- Open Access
- 19 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13  (20) , 11556
Optimization of Cyclone-Type Rotary Kiln Reactor for Carbonation of BOF Slag
Mineral carbonation of the basic oxygen furnace (BOF) slag produced in the steel-making process not only provides an effective approach for carbon dioxide storage, but also stabilizes the slag such that it can be reused as a construction material. Generally speaking, carbonation performance improves as the time for which the carbon dioxide resides within the reactor increases. This research proposes a method to increase the residence time of carbon dioxide in the cyclone converter slag carbonization kiln by adjusting the inclination angle and length of the feed pipe. Therefore, it has the same effect of increasing the flow path length of the cyclone in the reactor. The optimal values of the inclination angle and length of the gas inlet tube are determined using the robust Taguchi design method. Computational fluid dynamics simulation results show that the optimized reactor design increases the average residence time of carbon dioxide gas by 60.4%, compared with the original rotating reactor design with a straight (non-cyclonic) flow path. Moreover, the experimental results show that the optimized design increases the carbon dioxide storage capacity from 12.15 g per kilogram of BOF slag in the original rotary kiln reactor to 16.00 g in the re-designed reactor.
- 19 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13  (20) , 11556
Open AccessOptimization of Cyclone-Type Rotary Kiln Reactor for Carbonation of BOF Slag
Mineral carbonation of the basic oxygen furnace (BOF) slag produced in the steel-making process not only provides an effective approach for carbon dioxide storage, but also stabilizes the slag such that it can be reused as a construction material. Generally speaking, carbonation performance improves as the time for which the carbon dioxide resides within the reactor increases. This research proposes a method to increase the residence time of carbon dioxide in the cyclone converter slag carbonization kiln by adjusting the inclination angle and length of the feed pipe. Therefore, it has the same effect of increasing the flow path length of the cyclone in the reactor. The optimal values of the inclination angle and length of the gas inlet tube are determined using the robust Taguchi design method. Computational fluid dynamics simulation results show that the optimized reactor design increases the average residence time of carbon dioxide gas by 60.4%, compared with the original rotating reactor design with a straight (non-cyclonic) flow path. Moreover, the experimental results show that the optimized design increases the carbon dioxide storage capacity from 12.15 g per kilogram of BOF slag in the original rotary kiln reactor to 16.00 g in the re-designed reactor.
- 11 August 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 236  (2) , 245-253
Experimental investigation into spray cooling heat transfer performance of Al2O3-water nanofluid with different subcooling degrees
This study investigated the spray cooling heat transfer performance of Al2O3-water nanofluid given four different subcooling degrees (0 °C, 10 °C, 20 °C, and 30 °C). The results showed that the subcooled nanofluids were ranked in order of a reducing spray cooling heat transfer performance as follows: 20 °C, 10 °C, 0 °C, and 30 °C. On average, the heat transfer coefficient obtained using the nanofluid with 20 °C subcooling was around 8.3%, 8.6%, and 15.6% higher than that obtained with 10 °C, 0 °C, and 30 °C subcooling, respectively. However, the heat transfer performance decreased with an increasing spray operating time. The scanning electron microscopy observations showed that the reduction in the heat transfer coefficient was the result of a gradual increase in the thickness of the nano-adsorption layer on the heated surface as the spray operating time increased.
- 11 August 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 236  (2) , 245-253
Experimental investigation into spray cooling heat transfer performance of Al2O3-water nanofluid with different subcooling degrees
This study investigated the spray cooling heat transfer performance of Al2O3-water nanofluid given four different subcooling degrees (0 °C, 10 °C, 20 °C, and 30 °C). The results showed that the subcooled nanofluids were ranked in order of a reducing spray cooling heat transfer performance as follows: 20 °C, 10 °C, 0 °C, and 30 °C. On average, the heat transfer coefficient obtained using the nanofluid with 20 °C subcooling was around 8.3%, 8.6%, and 15.6% higher than that obtained with 10 °C, 0 °C, and 30 °C subcooling, respectively. However, the heat transfer performance decreased with an increasing spray operating time. The scanning electron microscopy observations showed that the reduction in the heat transfer coefficient was the result of a gradual increase in the thickness of the nano-adsorption layer on the heated surface as the spray operating time increased.
- Open Access
- 17 March 2021
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2021, 1-10
Analytical Investigation into Effects of Capillary Force on Condensate Film Flowing over Horizontal Semicircular Tube in Porous Medium
A theoretical investigation is performed into the problem of laminar filmwise condensation flow over a horizontal semicircular tube embedded in a porous medium and subject to capillary forces. The effects of the capillary force and gravity force on the condensation heat transfer performance are analyzed using an energy balance approach method. For analytical convenience, several dimensionless parameters are introduced, including the Jakob number Ja, Rayleigh number Ra, and capillary force parameter Boc. The resulting dimensionless governing equation is solved using the numerical shooting method to determine the effect of capillary forces on the condensate thickness. A capillary suction velocity can be obtained mathematically in the calculation process and indicates whether the gravity force is greater than the capillary force. It is shown that if the capillary force is greater than the condensate gravity force, the liquid condensate will be sucked into the two-phase zone. Under this condition, the condensate film thickness reduces and the heat transfer performance is correspondingly improved. Without considering the capillary force effects, the mean Nusselt number is also obtained in the present study as .
- 17 March 2021
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2021, 1-10
Open AccessAnalytical Investigation into Effects of Capillary Force on Condensate Film Flowing over Horizontal Semicircular Tube in Porous Medium
A theoretical investigation is performed into the problem of laminar filmwise condensation flow over a horizontal semicircular tube embedded in a porous medium and subject to capillary forces. The effects of the capillary force and gravity force on the condensation heat transfer performance are analyzed using an energy balance approach method. For analytical convenience, several dimensionless parameters are introduced, including the Jakob number Ja, Rayleigh number Ra, and capillary force parameter Boc. The resulting dimensionless governing equation is solved using the numerical shooting method to determine the effect of capillary forces on the condensate thickness. A capillary suction velocity can be obtained mathematically in the calculation process and indicates whether the gravity force is greater than the capillary force. It is shown that if the capillary force is greater than the condensate gravity force, the liquid condensate will be sucked into the two-phase zone. Under this condition, the condensate film thickness reduces and the heat transfer performance is correspondingly improved. Without considering the capillary force effects, the mean Nusselt number is also obtained in the present study as .