Measuring the Temperature Increase of an Ultrasonic Motor in a 3-Tesla Magnetic Resonance Imaging System
Open Access
Abstract
This paper aims to evaluate the temperature increase caused by a 3.0-T magnetic resonance imaging (MRI) system on an ultrasonic motor (USM) used to actuate surgical robots in the MRI environment. Four fiber-optic temperature sensors were attached to the USM. Temperature was monitored outside the five-Gauss boundary and then inside the bore for 20 min while the USM was powered on. The USM temperature was tested for two states of the scanner, “off” and “on”, by employing common clinical imaging sequences and echo planar imaging sequences. The USM showed a slight temperature increase while operating in the static field of the MRI. A considerable temperature increase (~10 °C) was observed when the scanner was on. The temperature increased to 60 °C, which is beyond the acceptable safe temperature and can result in thermal burns. Most of the temperature increase (80%) was due to effects of the static field on the motion of the rotating parts of the motor, while the remainder (20%) derived from heat deposited in the conductive components of the USM due to radiofrequency pulses and gradient field changes. To solve the temperature increase, the metal components of the USM’s case can be replaced by silicon carbide.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (NSERC) - Collaborative Health Research Projects (CHRP) Grant (385860-10)
This publication has 26 references indexed in Scilit:
- Interventional MRI: Minimal-invasive Surgery under MR guidance2011
- Robot-assisted MRI-guided prostatic interventionsRobotica, 2009
- Preventing Accidents and Injuries in the MRI SuiteJournal of Radiology Nursing, 2008
- The case for MR‐compatible robotics: a review of the state of the artThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- New real-time MR image-guided surgical robotic system for minimally invasive precision surgeryInternational Journal of Computer Assisted Radiology and Surgery, 2008
- Magnetic Resonance–Compatible Robotic and Mechatronics Systems for Image-Guided Interventions and Rehabilitation: A Review StudyAnnual Review of Biomedical Engineering, 2007
- “MRI Stealth” robot for prostate interventionsMinimally Invasive Therapy & Allied Technologies, 2007
- Surgical assist robot for the active navigation in the intraoperative MRI: hardware design issues2002
- Interactive MR image guidance for neurosurgical and minimally invasive procedures1999
- Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgeryJournal of Image Guided Surgery, 1995