Latest Publications

  • Open Access

    Application of a Nonlinear Hammerstein-Wiener Estimator in the Development and Control of a Magnetorheological Fluid Haptic Device for Robotic Bone Biopsy

    by Elnaz Shokrollahi, Andrew A. Goldenberg, James M. Drake, Kyle W. Eastwood, Matthew Kang

    A force generator module (FGM) based on magnetorheological fluid (MRF) was developed to provide force-feedback information for applications in tele-robotic bone biopsy procedures. The FGM is capable of rapidly re-producing a wide range of forces that are common in bone biopsy applications. As a result of the nonlinear nature of MRF, developing robust controllers for these mechanisms can be challenging. In this paper, we present a case study motivated by robotic bone biopsy. We use a non-linear Hammerstein-Wiener (H-W) estimator to address this challenge. The case is presented through three studies. First, an experiment to develop design constraints is presented and describes biopsy force measurements for various animal tissues. Required output forces were found to range between <1 N and <50 N. A second study outlines the design of the FGM and presents the experimental characterization of the hysteretic behavior of the MRF. This data is then used as estimators and validators to develop the nonlinear Hammerstein-Wiener (H-W) model of the MRF. Validation experiments found that the H-W model is capable of predicting the behavior of the MRF device with 95% accuracy and can eliminate hysteresis in a closed-loop control system. The third study demonstrates the FGM used in a 1-DOF haptic controller in a simulated robotic bone-biopsy. The H-W control tracked the input signal while compensating for magnetic hysteresis to achieve optimal performance. In conclusion, the MRF-based device can be used in surgical robotic operations that require a high range of force measurements.


  • Open Access

    Quantification of Force and Torque Applied by a High-Field Magnetic Resonance Imaging System on an Ultrasonic Motor for MRI-Guided Robot-Assisted Interventions

    by Peyman Shokrollahi, James M. Drake, Andrew A. Goldenberg

    The risk of accidental dislodgement of robot-operated surgical mechanisms can lead to morbidity or mortality. The force and torque applied by a 3.0-tesla scanner on an ultrasonic motor are not fully known. The force and torque may displace the motor, which is not fully magnetic resonance imaging (MRI)-compatible but can be safely used in MR environments. A suspension apparatus was designed to measure the angles of deflection and rotation applied to the motor by MR magnetic fields. Three orientations and two power states of the motor were assessed inside the MR bore. The displacement force and torque were measured at eight locations with respect to the bore. The displacement force on the motor from 10 cm outside the magnet bore to 20 cm inside the bore ranged from 3 to 7 gF. The experimental measurements are in agreement with the theoretical values. Running the motor altered the force by 1 gF. The force does not significantly change when the MRI scanner is on. Considerable displacement force is applied to the motor, and no deflection torque is observed. Quantified values can be used to solve dynamic equations for robotic mechanisms intended for MRI-guided operations.


  • Open Access

    Measuring the Temperature Increase of an Ultrasonic Motor in a 3-Tesla Magnetic Resonance Imaging System

    by Peyman Shokrollahi, James M. Drake, Andrew A. Goldenberg

    This paper aims to evaluate the temperature increase caused by a 3.0-T magnetic resonance imaging (MRI) system on an ultrasonic motor (USM) used to actuate surgical robots in the MRI environment. Four fiber-optic temperature sensors were attached to the USM. Temperature was monitored outside the five-Gauss boundary and then inside the bore for 20 min while the USM was powered on. The USM temperature was tested for two states of the scanner, “off” and “on”, by employing common clinical imaging sequences and echo planar imaging sequences. The USM showed a slight temperature increase while operating in the static field of the MRI. A considerable temperature increase (~10 °C) was observed when the scanner was on. The temperature increased to 60 °C, which is beyond the acceptable safe temperature and can result in thermal burns. Most of the temperature increase (80%) was due to effects of the static field on the motion of the rotating parts of the motor, while the remainder (20%) derived from heat deposited in the conductive components of the USM due to radiofrequency pulses and gradient field changes. To solve the temperature increase, the metal components of the USM’s case can be replaced by silicon carbide.


  • Open Access

    Signal-to-noise ratio evaluation of magnetic resonance images in the presence of an ultrasonic motor

    by Peyman Shokrollahi, James M. Drake, Andrew A. Goldenberg

    Safe robot-assisted intervention using magnetic resonance imaging (MRI) guidance requires the precise control of assistive devices, and most currently available tools are rarely MRI-compatible. To obtain high precision, it is necessary to characterize and develop existing MRI-safe actuators for use in a high magnetic field (≥3 T). Although an ultrasonic motor (USM) is considered to be an MRI-safe actuator, and can be used in the vicinity of a high field scanner, its presence interferes with MR images. Although an MR image provides valuable information regarding the pathology of a patient’s body, noise, generally of a granular type, decreases the quality of the image and jeopardizes the true evaluation of any existing pathological issues. An eddy current induced in the conductor material of the motor structure can be a source of noise when the motor is close to the isocenter of the image. We aimed to assess the effects of a USM on the signal-to-noise ratio (SNR) of MR images in a 3-T scanner. The SNR was compared for four image sequences in transverse directions for three orientations of the motor (x, y, and z) when the motor was in the “off” state. The SNR was evaluated to assess three artifact reduction methods used to minimize the motor-induced artifacts. The SNR had a range of 5–10 dB for slices close to the motor in the x and y orientations, and increased to 15–20 dB for slices far from the motor. Averaging the SNR for slices in all cases gave an SNR loss of about 10 dB. The maximum SNR was measured in the z orientation. In this case, the SNR loss was almost the same as that of other motor orientations, approximately 10 dB, but with a higher range, approximately 20–40 dB. The selection of certain scanning parameters is necessary for reducing motor-generated artifacts. These parameters include slice selection and bandwidth. In developing any MRI-compatible assisted device actuated by a USM, this study recommends the use of an approximately 3-mm slice thickness with minimum bandwidth to achieve optimized SNR values when a USM is operating close to (within approximately 40 mm) the region being imaged. The SNR can be further enhanced by increasing the number of signal averages, but this is achieved only at the cost of increased scan duration.


  • Contributor contact details

    by S.J. Chua, B.J. Li, L. Sirleto, G. Coppola, M. Iodice, M. Casalino, M. Gioffre, I. Rendina, J. Tioh, R.J. Weber, et al.

  • Design and Analysis of a Hybrid Mobile Robot Mechanism With Compounded Locomotion and Manipulation Capability

    by Pinhas Ben-Tzvi, Andrew A. Goldenberg, Jean W. Zu

    This paper presents a novel design paradigm as well as the related detailed mechanical design embodiment of a mechanically hybrid mobile robot. The robot is composed of a combination of parallel and serially connected links resulting in a hybrid mechanism that consists of a mobile robot platform for locomotion and a manipulator arm for manipulation. Unlike most other mobile robot designs that have a separate manipulator arm module attached on top of the mobile platform, this design has the ability to simultaneously and interchangeably provide locomotion and manipulation capability. This robot enhanced functionality is complemented by an interchangeable track tension and suspension mechanism that is embedded in some of the mobile robot links to form the locomotion subsystem of the robot. The mechanical design was analyzed with a virtual prototype that was developed with MSC ADAMS software. The simulation was used to study the robot’s enhanced mobility characteristics through animations of different possible tasks that require various locomotion and manipulation capabilities. The design was optimized by defining suitable and optimal operating parameters including weight optimization and proper component selection. Moreover, the simulation enabled us to define motor torque requirements and maximize end-effector payload capacity for different robot configurations. Visualization of the mobile robot on different types of virtual terrains such as flat roads, obstacles, stairs, ditches, and ramps has helped in determining the mobile robot’s performance, and final generation of specifications for manufacturing a full scale prototype.


  • Autonomous Stair Climbing with Reconfigurable Tracked Mobile Robot

    by Pinhas Ben-Tzvi, Shingo Ito, Andrew A. Goldenberg

    Mobile robots have been developed for surveillance, reconnaissance and inspection as well as for operation in hazardous environments. Some are intended to explore not only natural terrains but also artificial environments, including stairs. This paper explores algorithms to autonomously climb stairs. The algorithms were derived and implemented for a specific mobile robot with the ability to traverse such obstacles by changing its tracks configuration. Furthermore, algorithms have been developed for conditions under which the mobile robot halts its motion during the climbing process when at risk of flipping over or falling down. The technical problems related to the implementation of some of these functions have been identified and analyzed, and their solutions validated and tested. The algorithms and solutions were validated experimentally, illustrating the effectiveness of autonomous climbing of stairs.


  • Implementation of Sensors and Control Paradigm for a Hybrid Mobile Robot Manipulator for Search and Rescue Operations

    by Pinhas Ben-Tzvi, Andrew A. Goldenberg, Jean W. Zu

    This paper presents the control paradigm and embedded sensors for a mobile robot manipulator whereby the mobile platform and manipulator arm are designed as one entity to support both locomotion and manipulation simultaneously and interchangeably in several configuration modes. Along with the description of the novel design architecture, we developed, constructed and tested a novel paradigm for on-board RF data communication among robot's joints. This paper also describes the sensor and camera layout and their implementation in the mobile robot manipulator. A modular and extensible power source system design with major key elements that allow for easy reconfiguration and expansion was also developed, implemented and tested for the hybrid mobile robot manipulator.


  • A Novel Control Architecture and Design of Hybrid Locomotion and Manipulation Tracked Mobile Robot

    by Pinhas Ben-Tzvi, Andrew A. Goldenberg, Jean W. Zu

    This paper presents a novel control architecture for a tracked hybrid mobile robot that was designed based on hybridization of the mobile platform and manipulator arm as one entity for robot locomotion as well as manipulation. The novel concept of the mechanical design is described and analyzed with the aid of a virtual prototype that was developed with multi-body dynamic motion simulation software. The simulation results were used to demonstrate the robot's expected functionality and demonstrate its capability while utilizing them for design optimization and ongoing construction of the first physical prototype. Along with the novel design we focus on a novel concept for on-board RF communication among robot's joints. This paper also summarizes the qualitative and quantitative performance of the hybrid robot in terms of mobility, communication, power, sensors, and control.


  • Development of Control System Architecture for Modular and Re-configurable Robot Manipulators

    by Daqing Wang, Andrew A. Goldenberg, Guangjun Liu

    Architecture forms the backbone of robotic control systems and has to be carefully studied before the system is built. In this paper, after insight and exclusive discussions on control system architecture requirements of modular and re-configurable robot manipulators are presented, a hybrid architecture is proposed and described in details. The proposed architecture has been implemented on a modular and reconfigurable robot, and the testing results show the validity of the proposed architecture.