Use of lumen-apposing metal stents (LAMS) in the management of gastro jejunostomy stricture following Roux-en-Y Gastric Bypass for obesity: a prospective series
Open Access
- 17 July 2021
- journal article
- research article
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-6
Abstract
Background: Chronic strictures following Roux-en-Y Gastric Bypass (RYGB) are a troublesome complication that can lead to significant morbidity. The use of stents has been described but the need for X-ray and risk of migration have meant limited use in the management of these strictures. Lumen apposing metal stents (LAMS) have traditionally been used for management of pancreatic pseudocysts. They don’t require X-ray and are easy to deploy with a short learning curve. This paper explores the use of LAMS to treat post RYGB strictures and explores their safety and efficacy. Methods: A prospective study over a 4-year period looking at 14 patients with post RYGB strictures. These patients were privately insured patients operated within a tertiary Private facility. The patients were followed up for between 1 and 3 years. We have prospectively collected data on the efficacy and safety of LAMS in these patients. Patients were followed up until stent removal or definitive surgery to correct a stricture. Results: 421 patients underwent RYGB in the study period. 14 (3.3%) of these patients developed a stricture that resulted in insertion of LAMS. There was no immediate complications and 12 patients had complete resolution of their stricture. There were no reoperations due to migration related issues although a migration rate of 19% was noted. 2 patients required surgery to correct refractory strictures not relieved by a LAMS stent, both of these were strictures associated with marginal ulceration of the gastro jejunostomy. Conclusion: LAMS are a safe and effective method to manage post RYGB strictures. They have a high rate of resolution of strictures and can be safely deployed across strictures with no immediate complication. Migration does still appear to be a problem, however, does not appear to affect patient outcome or increase morbidity. Insertion is straightforward and doesn’t appear to be associated with a long learning curve.Keywords
All Related Versions
This publication has 23 references indexed in Scilit:
- Lumen-apposing covered self-expanding metal stent for management of benign gastrointestinal stricturesEndoscopy International Open, 2015
- Clinical outcomes following stent placement in refractory benign esophageal stricture: a systematic review and meta-analysisEndoscopy, 2015
- Gastrojejunostomy stricture rate: comparison between antecolic and retrocolic laparoscopic Roux-en-Y gastric bypassSurgery for Obesity and Related Diseases, 2015
- Low Anastomotic Stricture Rate After Roux-en-Y Gastric Bypass Using a 21-mm Circular Stapling DeviceObesity Surgery, 2012
- Linear Stapler Technique May Be Safer than Circular in Gastrojejunal Anastomosis for Laparoscopic Roux-en-Y Gastric Bypass: A Meta-analysis of Comparative StudiesObesity Surgery, 2011
- Comparison of Hand-Sewn, Linear-Stapled, and Circular-Stapled Gastrojejunostomy in Laparoscopic Roux-en-Y Gastric BypassObesity Surgery, 2011
- Refractory strictures after Roux-en-Y gastric bypass: operative managementSurgery for Obesity and Related Diseases, 2011
- Self-expanding plastic stents in treatment of benign esophageal conditionsGastrointestinal Endoscopy, 2008
- Successful endoscopic management of gastrojejunal anastomotic strictures after Roux-en-Y gastric bypassGastrointestinal Endoscopy, 2007
- Treatment of Gastro-Jejunal Leakage and Fistulization after Gastric Bypass with Coated Self-Expanding StentsObesity Surgery, 2006