Adam Peter Skidmore
Research Subjects
Research Interests
Adam Peter Skidmore has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Edo O Aarts
Rijnstate
3 shared publicationsEdo O. Aarts
WeightWorks Clinics, Surgical weight Loss Clinic, Amersfoort, The Netherlands
2 shared publications- Courtney Holinger
General Surgery , Albury Wodonga Health, Albury, NSW , Australia
1 shared publication - Jacob Chisholm
Flinders Private Hospital, Adelaide, SA, USA
1 shared publication - Lilian Kow
Flinders University, Adelaide, Australia
1 shared publication Nicholas Williams
School of Medicine Sydney University of Notre Dame Wagga Wagga Australia
1 shared publication
Latest Publications
- Open Access
- 14 March 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 95 (5) , 849-851
Professional indemnity insurance rates for metabolic bariatric surgeons in Australia: survey results
- 14 March 2025
- Published by Wiley in Anz Journal of Surgery
- Vol. 95 (5) , 849-851
Open AccessProfessional indemnity insurance rates for metabolic bariatric surgeons in Australia: survey results
- Open Access
- 1 March 2022
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2022 (3) , rjac051
Case report: gastric sleeve surgery leads to new onset Crohn’s disease
We report on the case of a 23-year-old male, who developed diffuse gastrointestinal Crohn’s disease 2 months after gastric sleeve surgery. Prior to the surgery this patient had no previous symptoms of an inflammatory bowel disease (IBD). His only risk factor for IBD was a positive family history and he was otherwise well. As bariatric weight loss surgery becomes more widely practiced, there have been multiple sources indicating a possible causal link between bariatric surgery and new onset Crohn’s disease.
- 1 March 2022
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2022 (3) , rjac051
Open AccessCase report: gastric sleeve surgery leads to new onset Crohn’s disease
We report on the case of a 23-year-old male, who developed diffuse gastrointestinal Crohn’s disease 2 months after gastric sleeve surgery. Prior to the surgery this patient had no previous symptoms of an inflammatory bowel disease (IBD). His only risk factor for IBD was a positive family history and he was otherwise well. As bariatric weight loss surgery becomes more widely practiced, there have been multiple sources indicating a possible causal link between bariatric surgery and new onset Crohn’s disease.
- Open Access
- 17 July 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-6
Use of lumen-apposing metal stents (LAMS) in the management of gastro jejunostomy stricture following Roux-en-Y Gastric Bypass for obesity: a prospective series
Background: Chronic strictures following Roux-en-Y Gastric Bypass (RYGB) are a troublesome complication that can lead to significant morbidity. The use of stents has been described but the need for X-ray and risk of migration have meant limited use in the management of these strictures. Lumen apposing metal stents (LAMS) have traditionally been used for management of pancreatic pseudocysts. They don’t require X-ray and are easy to deploy with a short learning curve. This paper explores the use of LAMS to treat post RYGB strictures and explores their safety and efficacy. Methods: A prospective study over a 4-year period looking at 14 patients with post RYGB strictures. These patients were privately insured patients operated within a tertiary Private facility. The patients were followed up for between 1 and 3 years. We have prospectively collected data on the efficacy and safety of LAMS in these patients. Patients were followed up until stent removal or definitive surgery to correct a stricture. Results: 421 patients underwent RYGB in the study period. 14 (3.3%) of these patients developed a stricture that resulted in insertion of LAMS. There was no immediate complications and 12 patients had complete resolution of their stricture. There were no reoperations due to migration related issues although a migration rate of 19% was noted. 2 patients required surgery to correct refractory strictures not relieved by a LAMS stent, both of these were strictures associated with marginal ulceration of the gastro jejunostomy. Conclusion: LAMS are a safe and effective method to manage post RYGB strictures. They have a high rate of resolution of strictures and can be safely deployed across strictures with no immediate complication. Migration does still appear to be a problem, however, does not appear to affect patient outcome or increase morbidity. Insertion is straightforward and doesn’t appear to be associated with a long learning curve.
- 17 July 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-6
Open AccessUse of lumen-apposing metal stents (LAMS) in the management of gastro jejunostomy stricture following Roux-en-Y Gastric Bypass for obesity: a prospective series
Background: Chronic strictures following Roux-en-Y Gastric Bypass (RYGB) are a troublesome complication that can lead to significant morbidity. The use of stents has been described but the need for X-ray and risk of migration have meant limited use in the management of these strictures. Lumen apposing metal stents (LAMS) have traditionally been used for management of pancreatic pseudocysts. They don’t require X-ray and are easy to deploy with a short learning curve. This paper explores the use of LAMS to treat post RYGB strictures and explores their safety and efficacy. Methods: A prospective study over a 4-year period looking at 14 patients with post RYGB strictures. These patients were privately insured patients operated within a tertiary Private facility. The patients were followed up for between 1 and 3 years. We have prospectively collected data on the efficacy and safety of LAMS in these patients. Patients were followed up until stent removal or definitive surgery to correct a stricture. Results: 421 patients underwent RYGB in the study period. 14 (3.3%) of these patients developed a stricture that resulted in insertion of LAMS. There was no immediate complications and 12 patients had complete resolution of their stricture. There were no reoperations due to migration related issues although a migration rate of 19% was noted. 2 patients required surgery to correct refractory strictures not relieved by a LAMS stent, both of these were strictures associated with marginal ulceration of the gastro jejunostomy. Conclusion: LAMS are a safe and effective method to manage post RYGB strictures. They have a high rate of resolution of strictures and can be safely deployed across strictures with no immediate complication. Migration does still appear to be a problem, however, does not appear to affect patient outcome or increase morbidity. Insertion is straightforward and doesn’t appear to be associated with a long learning curve.
- Open Access
- 28 June 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1
Correction to: Preventing Peterson’s space hernia using a BIO synthetic mesh
- 28 June 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1
Open AccessCorrection to: Preventing Peterson’s space hernia using a BIO synthetic mesh
- Open Access
- 4 May 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-6
Preventing Petersen’s space hernia using a BIO synthetic mesh
Background: Internal hernias occur after Roux-en-Y gastric bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more. Setting: Two large private hospitals specialized in bariatric surgery. Methods: All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Petersen’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh. Results: The glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Petersen’s space compared to 0.5% of patients (p < 0.001) who had a combined sutured and BIO Mesh Closure of their Petersen’s space defect. Although this was an ideal technique for Petersen’s space, it led to 1% of entero-enterostomy kinking due to the firm adhesion formation. Conclusion: Gluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Petersen’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Petersen’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- 4 May 2021
- Published by Springer Nature in BMC Surgery
- Vol. 21 (1) , 1-6
Open AccessPreventing Petersen’s space hernia using a BIO synthetic mesh
Background: Internal hernias occur after Roux-en-Y gastric bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more. Setting: Two large private hospitals specialized in bariatric surgery. Methods: All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Petersen’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh. Results: The glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Petersen’s space compared to 0.5% of patients (p < 0.001) who had a combined sutured and BIO Mesh Closure of their Petersen’s space defect. Although this was an ideal technique for Petersen’s space, it led to 1% of entero-enterostomy kinking due to the firm adhesion formation. Conclusion: Gluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Petersen’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Petersen’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- Open Access
- 20 April 2021
- Published by Springer Nature in Research Square
Use of Lumen-Apposing Metal Stents (LAMS) in the Management of Gastro Jejunostomy Stricture Following Roux En Y Gastric Bypass for Obesity.
Background Chronic strictures following Roux en Y Gastric Bypass (RYGB) are a troublesome complication that can lead to significant morbidity. The use of stents has been described but the need for X-ray and risk of migration have meant limited use in the management of these strictures. Lumen apposing metal stents (LAMS) have traditionally been used for management of pancreatic pseudocysts. They don’t require X-ray and are easy to deploy with a short learning curve. This paper explores the use of LAMS to treat post RYGB strictures and explores their safety and efficacy.MethodsA prospective study over a 4-year period looking at 14 patients with post RYGB strictures. These patients have been followed up for between 1 and 3 years. We have prospectively collected data on the efficacy and safety of LAMS in these patientsResults421 patients underwent RYGB in the study period. 14 of these patients developed a stricture that resulted in insertion of LAMS. There was no immediate complications and 12 patients had complete resolution of their stricture. There were no migration related issues.ConclusionLAMS are a safe and effective method to manage post RYGB strictures. They have a high rate of resolution of strictures and can be safely deployed across strictures with no immediate complication. Migration does not appear to be a problem. Insertion is straightforward and doesn’t appear to be associated with a long learning curve.
- 20 April 2021
- Published by Springer Nature in Research Square
Open AccessUse of Lumen-Apposing Metal Stents (LAMS) in the Management of Gastro Jejunostomy Stricture Following Roux En Y Gastric Bypass for Obesity.
Background Chronic strictures following Roux en Y Gastric Bypass (RYGB) are a troublesome complication that can lead to significant morbidity. The use of stents has been described but the need for X-ray and risk of migration have meant limited use in the management of these strictures. Lumen apposing metal stents (LAMS) have traditionally been used for management of pancreatic pseudocysts. They don’t require X-ray and are easy to deploy with a short learning curve. This paper explores the use of LAMS to treat post RYGB strictures and explores their safety and efficacy.MethodsA prospective study over a 4-year period looking at 14 patients with post RYGB strictures. These patients have been followed up for between 1 and 3 years. We have prospectively collected data on the efficacy and safety of LAMS in these patientsResults421 patients underwent RYGB in the study period. 14 of these patients developed a stricture that resulted in insertion of LAMS. There was no immediate complications and 12 patients had complete resolution of their stricture. There were no migration related issues.ConclusionLAMS are a safe and effective method to manage post RYGB strictures. They have a high rate of resolution of strictures and can be safely deployed across strictures with no immediate complication. Migration does not appear to be a problem. Insertion is straightforward and doesn’t appear to be associated with a long learning curve.
- Open Access
- 11 December 2020
- Published by Springer Nature in Research Square
Preventing Peterson’s space Hernia Using a Bio Synthetic Mesh
BackgroundInternal hernias occur after Roux-en-Y Gastric Bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more.SettingTwo large private hospitals specialized in bariatric surgery.MethodsAll patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Peterson’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh.ResultsThe glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Peterson’s space compared to 0.5% of patients (pConclusionGluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- 11 December 2020
- Published by Springer Nature in Research Square
Open AccessPreventing Peterson’s space Hernia Using a Bio Synthetic Mesh
BackgroundInternal hernias occur after Roux-en-Y Gastric Bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more.SettingTwo large private hospitals specialized in bariatric surgery.MethodsAll patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Peterson’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh.ResultsThe glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Peterson’s space compared to 0.5% of patients (pConclusionGluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- Open Access
- 20 May 2020
- Published by Springer Nature in Research Square
Preventing Peterson’s space Hernia Using a Bio Synthetic Mesh
Introduction Internal hernias occur after Roux-en-Y Gastric Bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more.Setting Two large private hospitals specialized in bariatric surgery.Methods All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Peterson’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh.Results The glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Peterson’s space compared to 0.5% of patients (pConclusion Gluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- 20 May 2020
- Published by Springer Nature in Research Square
Open AccessPreventing Peterson’s space Hernia Using a Bio Synthetic Mesh
Introduction Internal hernias occur after Roux-en-Y Gastric Bypass surgery (RYGB) when small bowel herniates into the intermesenteric spaces that have been created. The closure technique used is related to the internal hernia risks outcomes. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. By closing over a BIO mesh, the risk might be reduced even more.Setting Two large private hospitals specialized in bariatric surgery.Methods All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In all patients, the entero-enterostomy (EE) was closed using a double layered non-absorbable suture. In 2014, Peterson’s space was closed exclusively using glue, the years hereafter in a similar fashion as the EE, combined with a piece of glued BIO Mesh.Results The glued RYGB patients showed 25% of patients with an internal hernia (14%) or open Peterson’s space compared to 0.5% of patients (pConclusion Gluing the intermesenteric spaces is not beneficial but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is above all safe, effective and led to an almost complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture should give more insights into which is the optimal closure technique.
- Open Access
- 11 November 2019
- Published by Springer Nature in Research Square
Preventing Peterson’s space Hernia Using a Bio Synthetic Mesh
Introduction Up to 30% of all Bariatric procedures performed worldwide still are Roux-en-Y Gastric Bypasses (RYGB). Internal hernia’s occur when small bowel herniates into the intermesenteric spaces created when the roux limb is mobilised for anastomosis to the gastric pouch. To prevent internal hernia’s to occur many surgeons nowadays close the mesenteric defects during primary RYGB. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. However the technique of closure seems to be related to these reduced internal hernia risks outcomes while for example closure with staples does reduce the amount of internal hernia’s but in a much lesser extent. Setting Two large private hospitals specialized in bariatric surgeryMethods All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In the first year Peterson’s space was closed using glue, the years hereafter it was closed using a double layered non absorbable suture combined with a piece of glued BIO Mesh.Results The first group of glued RYGB patients showed 15% of patients with an internal hernia through Peterson’s space compared to 0% of patients (p<0.001) who had a combined sutured and BIO Mesh Closure of their Peterson’s space defect. Although an ideal technique for Peterson’s space, it led to 1% of entero-enterostomy kinking due to firm adhesions.Conclusion Closing this defect with clips or sutures partially reduces the chances on herniation, but not completely. Gluing this defect is not beneficial, but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is at least safe, effective and led to a complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture would give more insights in which is the optimal closure technique.
- 11 November 2019
- Published by Springer Nature in Research Square
Open AccessPreventing Peterson’s space Hernia Using a Bio Synthetic Mesh
Introduction Up to 30% of all Bariatric procedures performed worldwide still are Roux-en-Y Gastric Bypasses (RYGB). Internal hernia’s occur when small bowel herniates into the intermesenteric spaces created when the roux limb is mobilised for anastomosis to the gastric pouch. To prevent internal hernia’s to occur many surgeons nowadays close the mesenteric defects during primary RYGB. Using a non-resorbable double layered suture, this risk can be significantly reduced from 8.9 to 2.5% in the first three postoperative years. However the technique of closure seems to be related to these reduced internal hernia risks outcomes while for example closure with staples does reduce the amount of internal hernia’s but in a much lesser extent. Setting Two large private hospitals specialized in bariatric surgeryMethods All patients receiving a RYGB for (morbid) obesity between 2014 and 2018 were included in this retrospective study. In the first year Peterson’s space was closed using glue, the years hereafter it was closed using a double layered non absorbable suture combined with a piece of glued BIO Mesh.Results The first group of glued RYGB patients showed 15% of patients with an internal hernia through Peterson’s space compared to 0% of patients (p<0.001) who had a combined sutured and BIO Mesh Closure of their Peterson’s space defect. Although an ideal technique for Peterson’s space, it led to 1% of entero-enterostomy kinking due to firm adhesions.Conclusion Closing this defect with clips or sutures partially reduces the chances on herniation, but not completely. Gluing this defect is not beneficial, but placing a BIO Mesh in Peterson’s space is a promising new technique to induce local adhesions. It is at least safe, effective and led to a complete reduction of Peterson’s internal herniations. In the future, a randomized controlled trial comparing this technique to a double layered, non-absorbable suture would give more insights in which is the optimal closure technique.