The characterization of breast anatomical metrics using dedicated breast CT
- 28 March 2011
- journal article
- radiation imaging-physics
- Published by Wiley in Medical Physics
- Vol. 38 (4) , 2180-2191
Abstract
Purpose:: Accurate anatomical characterization of the breast is useful in breast phantom development and computer modeling of breast imaging technologies. Capitalizing on the three‐dimensional capabilities of dedicated breast CT (bCT), a number of parameters which describe breast shape and fibroglandular distribution are defined.Methods:: Among 219 bCT data sets, the effective diameter and length of the pendant breast as well as the breast volume were measured and characterized for each bra cup size. The volume glandular fraction (VGF) was determined as a function of patient age, BIRADS density, bra cup size, and breast diameter. The glandular fraction was examined in coronal and sagittal planes of the breast, and the radial distribution of breast glandular fraction within a coronal bCT image was examined for three breast regions. The areal glandular fraction (AGF) was estimated from two‐dimensional projections of the breast (simulated by projecting bCT data sets) and was compared to the corresponding VGF.Results:: The effective breast diameter and length increase with increasing bra cup size. The mean breast diameters (± standard error) of bra cup sizes A/AA, B, C, and D/DD were , , , and , respectively. VGF was lower among older women and those with larger breast diameter and larger bra cup size. VGF increased as a function of the reported BIRADS density. AGF increased with VGF. Fibroglandular tissue was distributed primarily in the central portion of the breast.Conclusions:: Breast metrics were examined and a number of parameters were defined which may be useful for breast modeling. The reported data may provide researchers with useful information for characterizing the breast for various imaging or dosimetry tasks.Keywords
Funding Information
- National Institutes of Health (R01 EB002138)
This publication has 10 references indexed in Scilit:
- The myth of the 50‐50 breastMedical Physics, 2009
- Glandular segmentation of cone beam breast CT volume images2007
- Technique factors and their relationship to radiation dose in pendant geometry breast CTMedical Physics, 2005
- A three-dimensional breast software phantom for mammography simulationPhysics in Medicine & Biology, 2003
- Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulationMedical Physics, 2002
- Statistical texture synthesis of mammographic images with super-blob lumpy backgroundsOptics Express, 1999
- Simulation model of mammographic calcifications based on the american college of radiology breast imaging reporting and data system, or BIRADSAcademic Radiology, 1998
- Real and simulated clustered microcalcifications in digital mammograms. ROC study of observer performanceMedical Physics, 1997
- Analysis of parenchymal density on mammograms in 1353 women 25-79 years old.American Journal of Roentgenology, 1996
- A simulation model of clustered breast microcalcificationsMedical Physics, 1994