Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain
Authors:
- Clemens MaaßCMClemens Maaß
- Matthias BaerMBMatthias Baer
- Marc KachelrießMKMarc Kachelrieß
- 24 July 2009
- journal article
- Published by Wiley in Medical Physics
- Vol. 36 (8) , 3818-3829
Abstract
Dual energy CT (DECT) measures the object of interest using two different x-ray spectra in order to provide energy-selective CT images or in order to get the material decomposition of the object. Today, two decomposition techniques are known. Image-based DECT uses linear combinations of reconstructed images to get an image that contains material-selective DECT information. Rawdata-based DECT correctly treats the available information by passing the rawdata through a decomposition function that uses information from both rawdata sets to create DECT specific (e.g., material-selective) rawdata. Then the image reconstruction yields material-selective images. Rawdata-based image decomposition generally obtains better image quality; however, it needs matched rawdata sets. This means that physically the same lines need to be measured for each spectrum. In today's CT scanners, this is not the case. The authors propose a new image-based method to combine mismatched rawdata sets for DECT information. The method allows for implementation in a scanner's rawdata precorrection pipeline or may be used in image domain. They compare the ability of the three methods (image-based standard method, proposed method, and rawdata-based standard method) to perform material decomposition and to provide monochromatic images. Thereby they use typical clinical and preclinical scanner arrangements including circular cone-beam CT and spiral CT. The proposed method is found to perform better than the image-based standard method and is inferior to the rawdata-based method. However, the proposed method can be used with the frequent case of mismatched data sets that exclude rawdata-based methods.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (FOR 661)
This publication has 9 references indexed in Scilit:
- Empirical dual energy calibration (EDEC) for cone‐beam computed tomographyMedical Physics, 2007
- Semiempirical model for generating tungsten target x‐ray spectraMedical Physics, 1991
- An algorithm for noise suppression in dual energy CT material density imagesIEEE Transactions on Medical Imaging, 1988
- Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studiesMedical Physics, 1986
- Evaluation of a prototype dual‐energy computed tomographic apparatus. II. Determination of vertebral bone mineral contentMedical Physics, 1986
- A beam-hardening correction using dual-energy computed tomographyPhysics in Medicine & Biology, 1985
- A Comparison of Noise and Dose in Conventional and Energy Selective Computed TomographyIEEE Transactions on Nuclear Science, 1979
- A Quantitative Theory of the Hounsfield Unit and Its Application to Dual Energy ScanningJournal of Computer Assisted Tomography, 1977
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976