CMClemens Maaß

Clemens Maaß

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clemens Maaß has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • CT image reconstruction with half precision floating-point values

    by Clemens Maaß, Matthias Baer, Marc Kachelrieß

    Purpose: Analytic CTimage reconstruction is a computationally demanding task. Currently, the even more demanding iterative reconstruction algorithms find their way into clinical routine because their image quality is superior to analytic image reconstruction. The authors thoroughly analyze a so far unconsidered but valuable tool of tomorrow’s reconstructionhardware (CPU and GPU) that allows implementing the forward projection and backprojection steps, which are the computationally most demanding parts of any reconstruction algorithm, much more efficiently.Methods: Instead of the standard 32 bit floating-point values (float), a recently standardized floating-point value with 16 bit (half) is adopted for data representation in image domain and in rawdata domain. The reduction in the total data amount reduces the traffic on the memory bus, which is the bottleneck of today’s high-performance algorithms, by 50%. In CT simulations and CT measurements, floatreconstructions (gold standard) and halfreconstructions are visually compared via difference images and by quantitative image quality evaluation. This is done for analytical reconstruction (filtered backprojection) and iterative reconstruction (ordered subset SART).Results: The magnitude of quantization noise, which is caused by a reduction in the data precision of both rawdata and image data during image reconstruction, is negligible. This is clearly shown for filtered backprojection and iterative ordered subset SART reconstruction. In filtered backprojection, the implementation of the backprojection should be optimized for low data precision if the image data are represented in half format. In ordered subset SART image reconstruction, no adaptations are necessary and the convergence speed remains unchanged.Conclusions: Half precision floating-point values allow to speed up CTimage reconstruction without compromising image quality.


  • New approaches to region of interest computed tomography

    by Clemens Maaß, Michael Knaup, Marc Kachelrieß

    In classical x-ray CT, the diameter of the field of measurement (FOM) must not fall below the transversal diameter of the patient or specimen. Thereby, the ratio of the diameter of FOM and the number of transversal detector elements typically defines the spatial resolution. The authors aim at improving the spatial resolution within a region of interest (ROI) by a factor of 10-100 while maintaining artifact-free CT image reconstruction inside and outside the ROI. Two novel methods are proposed for artifact-free reconstruction of the truncated ROI scan (data weighting method and data filtering method) and compared with the gold standard (data completion method) for this problem. First, an overview scan with low spatial resolution and a large FOM that exceeds the object transversally is performed. Second, a high-resolution scan is performed, where the scanner's magnification is changed such that the FOM matches the ROI at the cost of laterally truncated projection data. The gold standard is forward projecting the low-resolution scan on the rays missing in the high-resolution scan. The authors propose the data filtering method, which uses the low-resolution reconstruction and calculates a high frequency correction term from the high-resolution scan, and the data weighting method, which reconstructs the truncated high-resolution data and calculates a detruncation image from the low-resolution data. The methods are compared using a simulation of the Forbild head phantom and a measurement of a spinal disk implant. The results of the data weighting method and the data completion method show the same image quality. The data filtering method yields slightly inferior image quality that may still be sufficient for many applications. Both new methods considerably outperform the data completion method regarding the computational load. The new ROI reconstruction methods are superior to the gold standard regarding the computational load. Comparing the image quality with the gold standard, the data filtering method is slightly inferior and the data weighting method yields equal quality.


  • Exact dual energy material decomposition from inconsistent rays (MDIR)

    by Clemens Maaß, Esther Meyer, Marc Kachelrieß

    Purpose: Dual energy CT (DECT) allows calculating images that show the spatial distribution of the electron density and the atomic number or, more common, images of two basis material densities. In contrast, the Hounsfield unit that is shown in standard CT images is a measure of the x‐ray attenuation, which is a function of the atomic number and electron density. To acquire additional information, DECT measures the object of interest using two different detected x‐ray spectra. Most clinical CT scanners realize dual energy CT by fast tube voltage switching or by dual source dual detector arrangements and therefore do not allow measuring geometrically identical lines with each spectrum. Then, it is not possible to preprocess the raw data and calculate dual energy‐specific raw data sets. The combination of the information of both spectra rather needs to be carried out in image domain after image reconstruction. Compared to the ideal raw data‐based dual energy approaches, those image‐based DECT methods are inferior because they are not able to correctly deal with the polychromatic nature of the x‐rays. This article proposes a dedicated dual energy reconstruction algorithm for inconsistent rays that correctly accounts for all spectral effects.Methods: Material decomposition from inconsistent rays (MDIR) is an iterative method to indirectly perform raw data‐based DECT even though different lines were measured for both spectra. Its iterative nature allows treating the x‐ray polychromaticity correctly. The iterative process is initialized by density images that were obtained from an image‐based material decomposition. Those images suffer from errors that originate from the polychromatic nature of the spectra. These errors are calculated by polychromatic forward projection of each measured line. After correction of the initial material density images, the polychromatic forward projection is repeated with more accurate material density images, yielding a more accurate error calculation. To demonstrate the proposed method, simulations and measurements were performed using clinical and preclinical dual source dual energy CT scanners.Results: Two iterations of MDIR are sufficient to greatly improve the qualitative and quantitative information in material density images. It is shown that banding artifacts, cupping artifacts, and mean density errors can be completely eliminated. Simulations with high geometrical inconsistency between the rays of different spectra indicate that nearly exact material decomposition is possible with MDIR. Furthermore, simulations show that the method works well in the presence of materials with K‐edges within the detected spectrum. Phantom measurements using a clinical dual source CT scanner show the elimination of artifacts, which cause up to 4% mean density error.Conclusions: At moderate computational burden, the proposed MDIR algorithm yields images of the same high quality as direct raw data‐based DECT methods. In contrast to those, MDIR is applicable to the case of inconsistent rays, as it often occurs in clinical or preclinical CT. Compared to image‐based methods MDIR reduces artifacts and improves mean density errors in material density images. All dual energy postprocessing methods that are in use today, such as bone removal, virtual noncontrast images, etc., can be applied to the images provided by MDIR.


  • Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain

    by Clemens Maaß, Matthias Baer, Marc Kachelrieß

    Dual energy CT (DECT) measures the object of interest using two different x-ray spectra in order to provide energy-selective CT images or in order to get the material decomposition of the object. Today, two decomposition techniques are known. Image-based DECT uses linear combinations of reconstructed images to get an image that contains material-selective DECT information. Rawdata-based DECT correctly treats the available information by passing the rawdata through a decomposition function that uses information from both rawdata sets to create DECT specific (e.g., material-selective) rawdata. Then the image reconstruction yields material-selective images. Rawdata-based image decomposition generally obtains better image quality; however, it needs matched rawdata sets. This means that physically the same lines need to be measured for each spectrum. In today's CT scanners, this is not the case. The authors propose a new image-based method to combine mismatched rawdata sets for DECT information. The method allows for implementation in a scanner's rawdata precorrection pipeline or may be used in image domain. They compare the ability of the three methods (image-based standard method, proposed method, and rawdata-based standard method) to perform material decomposition and to provide monochromatic images. Thereby they use typical clinical and preclinical scanner arrangements including circular cone-beam CT and spiral CT. The proposed method is found to perform better than the image-based standard method and is inferior to the rawdata-based method. However, the proposed method can be used with the frequent case of mismatched data sets that exclude rawdata-based methods.


  • A new weighting function to achieve high temporal resolution in circular cone‐beam CT with shifted detectors

    by Clemens Maaß, Michael Knaup, Robert Lapp, Marek Karolczak, Willi A. Kalender, Marc Kachelrieß

    The size of the field of measurement (FOM) in computed tomography is limited by the size of the x‐ray detector. In general, the detector is mounted symmetrically with respect to the rotation axis such that the transaxial FOM diameter approximately equals the lateral dimensions of the detector when being demagnified to the isocenter. To enlarge the FOM one may laterally shift the detector by up to 50% of its size. Well‐known weighting functions must then be applied to the raw data prior to convolution and backprojection. In this case, a full scan or a scan with more than 360° angular coverage is required to obtain complete data. However, there is a small region, the inner FOM, that is covered redundantly and where a partial scan reconstruction may be sufficient. A new weighting function is proposed that allows one to reconstruct partial scans in that inner FOM while it reconstructs full scan or overscan data for the outer FOM, which is the part that contains no redundancies. The presented shifted detector partial scan algorithm achieves a high temporal resolution in the inner FOM while maintaining truncation‐free images for the outer part. The partial scan window can be arbitrarily shifted in the angular direction, what corresponds to shifting the temporal window of the data shown in the inner FOM. This feature allows for the reconstruction of dynamic CT data with high temporal resolution. The approach presented here is evaluated using simulated and measured data for a dual source micro‐CT scanner with rotating gantry.