Integration of Decay Time Analysis and Radiation Measurement for Quantum-Dot-Based Scintillator’s Characterization
Open Access
- 22 September 2022
- Vol. 10 (10) , 1920
Abstract
In this study, we demonstrated the process of an integrated apparatus for decay time analysis and gamma radiation measurement with a liquid-scintillator-based cadmium-doped zinc oxide (CZO) nanomaterial. Generally, time-resolved photon counting is an essential analysis method in the field of precision measurement in the quantum domain. Such photon counting equipment requires a pulse laser that can be repeated quickly while having a sharp pulse width of picoseconds or femtoseconds as a light source. Time-correlated single photon counting (TCSPC) equipment, which is currently a commercial product, is inconvenient for recent development research because the scintillator size and shape are limited. Here, neodymium-doped yttrium aluminum garnet (Nd/YAG) laser TCSPC equipment was constructed to analyze the fluorescence characteristics of scintillators having various sizes and shapes. Then, a liquid scintillator added with CZO nanomaterial was prepared and the Nd/YAG laser TCSPC equipment test was performed. As a result of measuring the scintillator using the manufactured Nd/YAG laser TCSPC equipment, the non-CZO liquid scintillator was analyzed at 2.30 ns and the liquid scintillator equipped with CZO-loaded nanomaterial was analyzed at 11.95 ns. It showed an error within 5% when compared with the result of commercial TCSPC equipment. In addition, it was verified that the Nd/YAG laser TCSPC system can sufficiently measure the decay time in nanoseconds (ns). Moreover, it was presented that the Compton edge energy of Cs−137 is 477.3 keV, which hardly generates a photoelectric effect, and Compton scattering mainly occurs.Keywords
Funding Information
- National Research Foundation of Korea (NRF) (NRF−2020M2C9A1068162, RS−2022–00154985)
- Ministry of Science and ICT (NRF−2020M2C9A1068162, RS−2022–00154985)
- Ministry of Science and ICT (NRF−2020M2C9A1068162, RS−2022–00154985)
This publication has 38 references indexed in Scilit:
- Fabrication of photoactive heterostructures based on quantum dots decorated with Au nanoparticlesScience and Technology of Advanced Materials, 2016
- Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detectionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Raman Spectroscopy for In-Line Water Quality Monitoring—Instrumentation and PotentialSensors, 2014
- Towards a portable Raman spectrometer using a concave grating and a time-gated CMOS SPADOptics Express, 2014
- Scintillation properties of quantum-dot doped styrene based plastic scintillatorsJournal of Luminescence, 2014
- A Study on Effective Management Scheme for Soil and Groundwater Contaminated by Radioactive Materials Due to Nuclear AccidentsJournal of Soil and Groundwater Environment, 2011
- Multispectral fluorescence lifetime imaging by TCSPCMicroscopy Research and Technique, 2007
- Fluorescence lifetime imaging for the two-photon microscope: time-domain and frequency-domain methodsJournal of Biomedical Optics, 2003
- Laser-based distance measurement using picosecond resolution time-correlated single-photon countingMeasurement Science and Technology, 2000
- Time-resolved detection and identification of single analyte molecules in microcapillaries by time-correlated single-photon counting (TCSPC)Review of Scientific Instruments, 1999