Sang-Bum Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sang-Bum Hong has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Changhyun Roh
Decommissioning Technology Division, Korea Atomic Energy Research Institute, Daejeon, Korea
11 shared publications - Bumkyung Seo
Decommissioning Technology Research Division, Korea Atomic Energy Research Institute, Daejeon 34057, Korea
9 shared publications - Jae Hak Cheong
Department of Nuclear Engineering, Kyung Hee University, Yongin-si, Republic of Korea
9 shared publications - Sujung Min
Department of Nuclear Engineering, Kyung-Hee University, Yongin-si 17104, Korea
8 shared publications Bum Kyoung Seo
3 shared publications- Hara Kang
Department of Nuclear Engineering, Kyung-Hee University, Yongin-si 17104, Gyeonggi-do, Korea
3 shared publications
Latest Publications
- Open Access
- 6 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112740
MDA reduction in HPGe gamma-ray spectrometry using a digital-twin–based intrinsic background construction
- 6 June 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 236, 112740
Open AccessMDA reduction in HPGe gamma-ray spectrometry using a digital-twin–based intrinsic background construction
- 30 December 2024
- Published by The Korean Radioactive Waste Society in Journal of Nuclear Fuel Cycle and Waste Technology
- Vol. 22 (4) , 421-440
Fabrication and Characterization of Multi-Shell Structure Quantum dot Doping Organic Scintillator
- 30 December 2024
- Published by The Korean Radioactive Waste Society in Journal of Nuclear Fuel Cycle and Waste Technology
- Vol. 22 (4) , 421-440
Fabrication and Characterization of Multi-Shell Structure Quantum dot Doping Organic Scintillator
- 24 February 2023
- Published by Springer Nature in Journal of Fluorescence
- Vol. 33 (5) , 1705-1716
Fabrication of a Liquid Scintillator based on 7-Diethylamino-4-Methylcoumarin for Radiation Detection
Organic liquid scintillation detectors are widely used to measure the presence of radiation. With these devices, there are advantages in that they are easy to manufacture, large in size, and have a short fluorescence decay time. However, they are not suitable for gamma spectroscopy because they are composed of a low-atomic-number material. In this regard, alternative materials for the secondary solute used in basic organic liquid scintillators have been investigated, and the applicability of alternative materials, the detection characteristics, and neutron/gamma identification tests were all assessed. 7-Diethylamino-4-methylcoumarin (DMC), selected as an alternative material, is a benzopyrone derivative in the form of colorless crystals with high fluorescence, a high quantum yield in the visible region, and excellent light stability. In addition, it has a large Stokes shift, and solubility in a solvent is good. Through an analysis in this study, it was found that the absorption wavelength range of DMC coincides with the emission wavelength range of PPO, which is the primary solute used with DMC. Finally, it was confirmed that the optimal concentration of DMC was 0.08 wt%. As a result of performing gamma and neutron measurement tests using a DMC-based liquid scintillator, it was found to perform well (FOM = 1.42) compared to a commercial liquid scintillator, BC-501A.
- 24 February 2023
- Published by Springer Nature in Journal of Fluorescence
- Vol. 33 (5) , 1705-1716
Fabrication of a Liquid Scintillator based on 7-Diethylamino-4-Methylcoumarin for Radiation Detection
Organic liquid scintillation detectors are widely used to measure the presence of radiation. With these devices, there are advantages in that they are easy to manufacture, large in size, and have a short fluorescence decay time. However, they are not suitable for gamma spectroscopy because they are composed of a low-atomic-number material. In this regard, alternative materials for the secondary solute used in basic organic liquid scintillators have been investigated, and the applicability of alternative materials, the detection characteristics, and neutron/gamma identification tests were all assessed. 7-Diethylamino-4-methylcoumarin (DMC), selected as an alternative material, is a benzopyrone derivative in the form of colorless crystals with high fluorescence, a high quantum yield in the visible region, and excellent light stability. In addition, it has a large Stokes shift, and solubility in a solvent is good. Through an analysis in this study, it was found that the absorption wavelength range of DMC coincides with the emission wavelength range of PPO, which is the primary solute used with DMC. Finally, it was confirmed that the optimal concentration of DMC was 0.08 wt%. As a result of performing gamma and neutron measurement tests using a DMC-based liquid scintillator, it was found to perform well (FOM = 1.42) compared to a commercial liquid scintillator, BC-501A.
- Open Access
- 28 December 2022
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Low-activity hotspot investigation method via scanning using deep learning
Small areas of elevated activity are a concern during a final status scan survey of residual radioactivity of decommissioned and contaminated sites. Due to the characteristics of scanning, the lower limit of detection is relatively high because the number of counts is low due to the short measurement time. To overcome this, an algorithm capable of finding hotspots with little information through deep learning was developed. The developed model using an artificial neural network was trained with the scan survey data acquired from a Monte Carlo-based computational simulation. A random mixing method was used to obtain sufficient training data. In order to respond properly to the experimental data, training and verification were conducted in various situations, in this case, in the presence or absence of random background counts and collimators and various source concentrations. Experimental data were obtained using a conventional detector, in this case, the 3″ × 3″ NaI(Tl). The advantages and limitations to the proposed method are as follows. Results were well predicted even in cases at less than 1 Bq/g, which is lower than the scanned minimum detectable concentration (MDC) of the detection system. It is a great advantage that it can detect contaminated areas that are lower than the existing scan’s minimum detectable concentration. However, the limitation is that it cannot be predicted, and the accuracy is low in multi-sourced scans. The source position and size are also important in residual radioactive evaluations, and scanning data images were evaluated in artificial neural network modes with suitable prediction results. The proposed methodology proved the high accuracy of hotspot prediction for low-activity sites and showed that this technology can be used as an efficient and economical hotspot scanning technology and can be extended to an automated system.
- 28 December 2022
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Open AccessLow-activity hotspot investigation method via scanning using deep learning
Small areas of elevated activity are a concern during a final status scan survey of residual radioactivity of decommissioned and contaminated sites. Due to the characteristics of scanning, the lower limit of detection is relatively high because the number of counts is low due to the short measurement time. To overcome this, an algorithm capable of finding hotspots with little information through deep learning was developed. The developed model using an artificial neural network was trained with the scan survey data acquired from a Monte Carlo-based computational simulation. A random mixing method was used to obtain sufficient training data. In order to respond properly to the experimental data, training and verification were conducted in various situations, in this case, in the presence or absence of random background counts and collimators and various source concentrations. Experimental data were obtained using a conventional detector, in this case, the 3″ × 3″ NaI(Tl). The advantages and limitations to the proposed method are as follows. Results were well predicted even in cases at less than 1 Bq/g, which is lower than the scanned minimum detectable concentration (MDC) of the detection system. It is a great advantage that it can detect contaminated areas that are lower than the existing scan’s minimum detectable concentration. However, the limitation is that it cannot be predicted, and the accuracy is low in multi-sourced scans. The source position and size are also important in residual radioactive evaluations, and scanning data images were evaluated in artificial neural network modes with suitable prediction results. The proposed methodology proved the high accuracy of hotspot prediction for low-activity sites and showed that this technology can be used as an efficient and economical hotspot scanning technology and can be extended to an automated system.
- Open Access
Integration of Decay Time Analysis and Radiation Measurement for Quantum-Dot-Based Scintillator’s Characterization
In this study, we demonstrated the process of an integrated apparatus for decay time analysis and gamma radiation measurement with a liquid-scintillator-based cadmium-doped zinc oxide (CZO) nanomaterial. Generally, time-resolved photon counting is an essential analysis method in the field of precision measurement in the quantum domain. Such photon counting equipment requires a pulse laser that can be repeated quickly while having a sharp pulse width of picoseconds or femtoseconds as a light source. Time-correlated single photon counting (TCSPC) equipment, which is currently a commercial product, is inconvenient for recent development research because the scintillator size and shape are limited. Here, neodymium-doped yttrium aluminum garnet (Nd/YAG) laser TCSPC equipment was constructed to analyze the fluorescence characteristics of scintillators having various sizes and shapes. Then, a liquid scintillator added with CZO nanomaterial was prepared and the Nd/YAG laser TCSPC equipment test was performed. As a result of measuring the scintillator using the manufactured Nd/YAG laser TCSPC equipment, the non-CZO liquid scintillator was analyzed at 2.30 ns and the liquid scintillator equipped with CZO-loaded nanomaterial was analyzed at 11.95 ns. It showed an error within 5% when compared with the result of commercial TCSPC equipment. In addition, it was verified that the Nd/YAG laser TCSPC system can sufficiently measure the decay time in nanoseconds (ns). Moreover, it was presented that the Compton edge energy of Cs−137 is 477.3 keV, which hardly generates a photoelectric effect, and Compton scattering mainly occurs.
Open AccessIntegration of Decay Time Analysis and Radiation Measurement for Quantum-Dot-Based Scintillator’s Characterization
In this study, we demonstrated the process of an integrated apparatus for decay time analysis and gamma radiation measurement with a liquid-scintillator-based cadmium-doped zinc oxide (CZO) nanomaterial. Generally, time-resolved photon counting is an essential analysis method in the field of precision measurement in the quantum domain. Such photon counting equipment requires a pulse laser that can be repeated quickly while having a sharp pulse width of picoseconds or femtoseconds as a light source. Time-correlated single photon counting (TCSPC) equipment, which is currently a commercial product, is inconvenient for recent development research because the scintillator size and shape are limited. Here, neodymium-doped yttrium aluminum garnet (Nd/YAG) laser TCSPC equipment was constructed to analyze the fluorescence characteristics of scintillators having various sizes and shapes. Then, a liquid scintillator added with CZO nanomaterial was prepared and the Nd/YAG laser TCSPC equipment test was performed. As a result of measuring the scintillator using the manufactured Nd/YAG laser TCSPC equipment, the non-CZO liquid scintillator was analyzed at 2.30 ns and the liquid scintillator equipped with CZO-loaded nanomaterial was analyzed at 11.95 ns. It showed an error within 5% when compared with the result of commercial TCSPC equipment. In addition, it was verified that the Nd/YAG laser TCSPC system can sufficiently measure the decay time in nanoseconds (ns). Moreover, it was presented that the Compton edge energy of Cs−137 is 477.3 keV, which hardly generates a photoelectric effect, and Compton scattering mainly occurs.
- Open Access
- 18 November 2021
- Published by MDPI AG in Electronics
- Vol. 10 (22) , 2833
Wireless Backpack System for Detection of Radioactive Cesium on Contaminated Soil Using Portable Plastic Scintillator with Efficient Readout Device
The miniaturization and usability of radiation detectors make it increasingly possible to use mobile instruments to detect and monitor gamma radiations. Here, a Bluetooth-based mobile detection system for integrated interaction in a backpack was designed and implemented to smart equipment for the detection of radioactive cesium on contaminated soil. The radiation measurement system was demonstrated in the form of a backpack using a quantum dot (QD)-loaded plastic scintillator manufactured and prepared directly in this study, and it can be measured by a person in the wireless framework of integrated interaction. The QD-loaded plastic scintillator was measured after setting the distance from the contaminated soil to 20, 50, and 100 mm. As a result, the detection efficiency of the commercial plastic scintillator (EJ-200) was calculated to be 11.81% and that of the QD-loaded plastic scintillator was 15.22%, which proved the higher detection efficiency performance than the commercial plastic scintillator. The measurement result was transmitted to a personal computer using Bluetooth as a portable system. In the future, this wireless system design could be expanded as a wireless communication system equipped with a global positioning system to detect and measure radioactively contaminated environments.
- 18 November 2021
- Published by MDPI AG in Electronics
- Vol. 10 (22) , 2833
Open AccessWireless Backpack System for Detection of Radioactive Cesium on Contaminated Soil Using Portable Plastic Scintillator with Efficient Readout Device
The miniaturization and usability of radiation detectors make it increasingly possible to use mobile instruments to detect and monitor gamma radiations. Here, a Bluetooth-based mobile detection system for integrated interaction in a backpack was designed and implemented to smart equipment for the detection of radioactive cesium on contaminated soil. The radiation measurement system was demonstrated in the form of a backpack using a quantum dot (QD)-loaded plastic scintillator manufactured and prepared directly in this study, and it can be measured by a person in the wireless framework of integrated interaction. The QD-loaded plastic scintillator was measured after setting the distance from the contaminated soil to 20, 50, and 100 mm. As a result, the detection efficiency of the commercial plastic scintillator (EJ-200) was calculated to be 11.81% and that of the QD-loaded plastic scintillator was 15.22%, which proved the higher detection efficiency performance than the commercial plastic scintillator. The measurement result was transmitted to a personal computer using Bluetooth as a portable system. In the future, this wireless system design could be expanded as a wireless communication system equipped with a global positioning system to detect and measure radioactively contaminated environments.
- Open Access
A Review of Nanomaterial Based Scintillators
Recently, nanomaterial-based scintillators are newly emerging technologies for many research fields, including medical imaging, nuclear security, nuclear decommissioning, and astronomical applications, among others. To date, scintillators have played pivotal roles in the development of modern science and technology. Among them, plastic scintillators have a low atomic number and are mainly used for beta-ray measurements owing to their low density, but these types of scintillators can be manufactured not in large sizes but also in various forms with distinct properties and characteristics. However, the plastic scintillator is mainly composed of C, H, O and N, implying that the probability of a photoelectric effect is low. In a gamma-ray nuclide analysis, they are used for time-related measurements given their short luminescence decay times. Generally, inorganic scintillators have relatively good scintillation efficiency rates and resolutions. And there are thus widely used in gamma-ray spectroscopy. Therefore, developing a plastic scintillator with performance capabilities similar to those of an inorganic scintillator would mean that it could be used for detection and monitoring at radiological sites. Many studies have reported improved performance outcomes of plastic scintillators based on nanomaterials, exhibiting high-performance plastic scintillators or flexible film scintillators using graphene, perovskite, and 2D materials. Furthermore, numerous fabrication methods that improve the performance through the doping of nanomaterials on the surface have been introduced. Herein, we provide an in-depth review of the findings pertaining to nanomaterial-based scintillators to gain a better understanding of radiological detection technological applications.
Open AccessA Review of Nanomaterial Based Scintillators
Recently, nanomaterial-based scintillators are newly emerging technologies for many research fields, including medical imaging, nuclear security, nuclear decommissioning, and astronomical applications, among others. To date, scintillators have played pivotal roles in the development of modern science and technology. Among them, plastic scintillators have a low atomic number and are mainly used for beta-ray measurements owing to their low density, but these types of scintillators can be manufactured not in large sizes but also in various forms with distinct properties and characteristics. However, the plastic scintillator is mainly composed of C, H, O and N, implying that the probability of a photoelectric effect is low. In a gamma-ray nuclide analysis, they are used for time-related measurements given their short luminescence decay times. Generally, inorganic scintillators have relatively good scintillation efficiency rates and resolutions. And there are thus widely used in gamma-ray spectroscopy. Therefore, developing a plastic scintillator with performance capabilities similar to those of an inorganic scintillator would mean that it could be used for detection and monitoring at radiological sites. Many studies have reported improved performance outcomes of plastic scintillators based on nanomaterials, exhibiting high-performance plastic scintillators or flexible film scintillators using graphene, perovskite, and 2D materials. Furthermore, numerous fabrication methods that improve the performance through the doping of nanomaterials on the surface have been introduced. Herein, we provide an in-depth review of the findings pertaining to nanomaterial-based scintillators to gain a better understanding of radiological detection technological applications.
- 1 October 2021
- Published by Coastal Education and Research Foundation in Journal of Coastal Research
- Vol. 114 (sp1) , 325-329
Development of Scan Survey Adjust Method for Radioactively Contaminated Sediment in Underwater Conditions
Kim, J.-H.; Cho, G.-S.; Lee, J.-J.; Hong, S.-B.; Lee, E.-J.; Lee, B.-C., and Seo, B.-K., 2021. Development of scan survey adjust method for radioactively contaminated sediment in underwater conditions. In: Lee, J.L.; Suh, K.-S.; Lee, B.; Shin, S., and Lee, J. (eds.), Crisis and Integrated Management for Coastal and Marine Safety. Journal of Coastal Research, Special Issue No. 114, pp. 325–329. Coconut Creek (Florida), ISSN 0749-0208. The nuclear power plants located near the coast and river to supply the cooling water. Therefore, unexpected radioactive materials leakage can contaminate the sediment on the coast, river, and lake. The conventional hotspot assessment methods are sampling and scan survey. The sampling method has limitations due to the sample representation, while the scan survey method is an easy way to assess hotspot distribution. However, the scan survey method can overestimate or underestimate the hotspot size depending on the radioactivity concentration, because this method determines the hotspot is exist when the measured count rate or dose rate exceeds the criteria level. In this study, the scan survey adjust method of sediment scan survey has developed. To this, the distribution of spatial effective dose rate was assessed by MCNP(Monte Carlo N-Particle) simulation. Also, the overestimation factor, which is the ratio of the actual hotspot size and estimated hotspot size was calculated. For the scan survey adjust method devised using the overestimation factor, maximum dose rate, and dose rate increase factor. Using this method, the scan survey experiment results were adjusted. As a result, 137Cs survey result that was underestimated were adjusted 11.51∼73.05% overestimate. 60Co survey result that was 2∼3 times overestimated was adjusted 2.02∼45.73% overestimate. Therefore, the scan survey adjusts method can prevent hotspot underestimation and reduced the relative error. This method can improve the accuracy of the hotspot scan survey in sediment.
- 1 October 2021
- Published by Coastal Education and Research Foundation in Journal of Coastal Research
- Vol. 114 (sp1) , 325-329
Development of Scan Survey Adjust Method for Radioactively Contaminated Sediment in Underwater Conditions
Kim, J.-H.; Cho, G.-S.; Lee, J.-J.; Hong, S.-B.; Lee, E.-J.; Lee, B.-C., and Seo, B.-K., 2021. Development of scan survey adjust method for radioactively contaminated sediment in underwater conditions. In: Lee, J.L.; Suh, K.-S.; Lee, B.; Shin, S., and Lee, J. (eds.), Crisis and Integrated Management for Coastal and Marine Safety. Journal of Coastal Research, Special Issue No. 114, pp. 325–329. Coconut Creek (Florida), ISSN 0749-0208. The nuclear power plants located near the coast and river to supply the cooling water. Therefore, unexpected radioactive materials leakage can contaminate the sediment on the coast, river, and lake. The conventional hotspot assessment methods are sampling and scan survey. The sampling method has limitations due to the sample representation, while the scan survey method is an easy way to assess hotspot distribution. However, the scan survey method can overestimate or underestimate the hotspot size depending on the radioactivity concentration, because this method determines the hotspot is exist when the measured count rate or dose rate exceeds the criteria level. In this study, the scan survey adjust method of sediment scan survey has developed. To this, the distribution of spatial effective dose rate was assessed by MCNP(Monte Carlo N-Particle) simulation. Also, the overestimation factor, which is the ratio of the actual hotspot size and estimated hotspot size was calculated. For the scan survey adjust method devised using the overestimation factor, maximum dose rate, and dose rate increase factor. Using this method, the scan survey experiment results were adjusted. As a result, 137Cs survey result that was underestimated were adjusted 11.51∼73.05% overestimate. 60Co survey result that was 2∼3 times overestimated was adjusted 2.02∼45.73% overestimate. Therefore, the scan survey adjusts method can prevent hotspot underestimation and reduced the relative error. This method can improve the accuracy of the hotspot scan survey in sediment.
- Open Access
- 25 August 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (9) , 239
Optimization of Plastic Scintillator for Detection of Gamma-Rays: Simulation and Experimental Study
Plastic scintillators are widely used in various radiation measurement applications, and the use of plastic scintillators for nuclear applications including decommissioning, such as gamma-ray detection and measurement, is an important concern. With regard to efficient and effective gamma-ray detection, the optimization for thickness of plastic scintillator is strongly needed. Here, we elucidate optimization of the thickness of high-performance plastic scintillator using high atomic number material. Moreover, the EJ-200 of commercial plastic scintillators with the same thickness was compared. Two computational simulation codes (MCNP, GEANT4) were used for thickness optimization and were compared with experimental results to verify data obtained by computational simulation. From the obtained results, it was confirmed that the difference in total counts was less than 10% in the thickness of the scintillator of 50 mm or more, which means optimized thickness for high efficiency gamma-ray detection such as radioactive 137Cs and 60CO. Finally, simulated results, along with experimental data, were discussed in this study. The results of this study can be used as basic data for optimizing the thickness of plastic scintillators using high atomic number elements for radiation detection and monitoring.
- 25 August 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (9) , 239
Open AccessOptimization of Plastic Scintillator for Detection of Gamma-Rays: Simulation and Experimental Study
Plastic scintillators are widely used in various radiation measurement applications, and the use of plastic scintillators for nuclear applications including decommissioning, such as gamma-ray detection and measurement, is an important concern. With regard to efficient and effective gamma-ray detection, the optimization for thickness of plastic scintillator is strongly needed. Here, we elucidate optimization of the thickness of high-performance plastic scintillator using high atomic number material. Moreover, the EJ-200 of commercial plastic scintillators with the same thickness was compared. Two computational simulation codes (MCNP, GEANT4) were used for thickness optimization and were compared with experimental results to verify data obtained by computational simulation. From the obtained results, it was confirmed that the difference in total counts was less than 10% in the thickness of the scintillator of 50 mm or more, which means optimized thickness for high efficiency gamma-ray detection such as radioactive 137Cs and 60CO. Finally, simulated results, along with experimental data, were discussed in this study. The results of this study can be used as basic data for optimizing the thickness of plastic scintillators using high atomic number elements for radiation detection and monitoring.
- Open Access
Phoswich Detectors in Sensing Applications
Herein, we review studies of the integration of Phoswich detectors with readout integrated circuits and the associated performance in a radiological sensing application. The basic concept and knowledge of interactions with scintillation materials and the mechanisms and characteristics of radiological detection are extensively discussed. Additionally, we summarize integrated multiple detection systems and Phoswich detectors in radiological measurements for their device performance. Moreover, we further exhibit recent progress and perspective in the future of Phoswich-based radiological detection and measurement. Finally, we provide perspectives to evaluate the detector performance for radiological detection and measurement. We expect this review can pave the way to understanding the recent status and future challenges for Phoswich detectors for radiological detection and measurement.
Open AccessPhoswich Detectors in Sensing Applications
Herein, we review studies of the integration of Phoswich detectors with readout integrated circuits and the associated performance in a radiological sensing application. The basic concept and knowledge of interactions with scintillation materials and the mechanisms and characteristics of radiological detection are extensively discussed. Additionally, we summarize integrated multiple detection systems and Phoswich detectors in radiological measurements for their device performance. Moreover, we further exhibit recent progress and perspective in the future of Phoswich-based radiological detection and measurement. Finally, we provide perspectives to evaluate the detector performance for radiological detection and measurement. We expect this review can pave the way to understanding the recent status and future challenges for Phoswich detectors for radiological detection and measurement.