Clinical effects of routine postdilatation of drug‐eluting stents
- 22 May 2013
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 83 (6) , 898-904
Abstract
Objectives: To assess the clinical effects of postdilatation of drug‐eluting stents (DES).Background: Subotpimal stent expansion occurs after DES deployment. Postidlatation may improve DES expansion, but it is unclear whether postdilatation may also improve clinical outcomes.Methods: Since July 2009, we adopted a strategy of routine postdilatation with noncompliant balloons of all DES, while previously postdilatation was performed only for suboptimal results. The first 279 consecutive patients (age 62 ± 9 years, 231 men) who underwent routine postilatation were compared with 262 patients (age 61 ± 9 years, 220 men) who received DES in the previous 6 months (standard treatment).Results: The two groups were similar for age, sex, clinical presentation, and main risk factors, including incidence of diabetes. Routine postdilatation resulted in an improved minimal lumen diameter at the end of the procedure (2.60 ± 0.34 vs. 2.51 ± 0.37 mm, P = 0.003). At 12‐month follow‐up incidence of MACE (including periprocedural myocardial infarction) was 19.5% in the standard treatment group and 12.5% in routine postdilatation group (P = 0.04), with a significant difference in target vessel revascularization (10.7% vs. 5.4%, P = 0.03), while incidence of myocardial infarction was not significantly different between the two groups (10.7% vs. 9.3%, P = 0.70). Stent thrombosis (definite or probable) occurred in 3 patients in standard treatment group, while no case of stent thrombosis occurred among patients treated with routine postdilatation (1.1% vs. 0%, P = 0.11).Conclusions: Our results suggest that a strategy of routine postdilatation with non compliant balloons may improve clinical outcomes of DES.Keywords
This publication has 25 references indexed in Scilit:
- Drug-Eluting StentingJACC: Cardiovascular Interventions, 2008
- Intravascular ultrasound assessment of drug-eluting stent expansionAmerican Heart Journal, 2007
- Adjunctive Balloon Postdilatation after Stent Deployment: Is It Still Necessary with Drug‐Eluting Stents?Journal of Interventional Cardiology, 2006
- Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantationJACC, 2005
- Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantationThe American Journal of Cardiology, 2005
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Is adjunctive balloon postdilatation necessary after coronary stent deployment? Final results from the POSTIT trialCatheterization and Cardiovascular Interventions, 2003
- Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery StenosesCirculation, 2003
- Intravascular ultrasound after low and high inflation pressure coronary artery stent implantationJACC, 1995
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992