Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Authors:
Preprint
- 20 February 2020
- preprint
- Published by Springer Nature in Research Square
Abstract
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.Keywords
All Related Versions
- Published version: BMC Musculoskeletal Disorders, 21 (1), 1.
This publication has 16 references indexed in Scilit:
- Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trialsEuropean Spine Journal, 2017
- Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sectionsEuropean Spine Journal, 2017
- Pedicle screw placement accuracy of bone-mounted miniature robot systemMedicine, 2017
- Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysisInternational Journal of Computer Assisted Radiology and Surgery, 2016
- Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric populationJournal of Robotic Surgery, 2016
- Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic reviewEuropean Spine Journal, 2013
- AO spine injury classification system: a revision proposal for the thoracic and lumbar spineEuropean Spine Journal, 2013
- An Assistive Image-Guided Surgical Robot System Using O-Arm Fluoroscopy for Pedicle Screw Insertion: Preliminary and Cadaveric StudyNeurosurgery, 2010
- Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placementThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990