Yi Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yi Liao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Fang Zhou
Department of Orthopedics, The Karamay Central Hospital, Karamay, 834000, China
5 shared publicationsJian Wang
Department of Orthopedics, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China
5 shared publicationsWang Shaobo
Department of Orthopedics, The Karamay Central Hospital, Karamay, 834000, China
5 shared publicationsWu Hongzi
Department of Orthopedics, The Karamay Central Hospital, Karamay, 834000, China
5 shared publicationsYang Rui
Department of Orthopedics, The Karamay Central Hospital, Karamay, 834000, China
5 shared publicationsZhang Ke
Department of Orthopedics, The Karamay Central Hospital, Karamay, 834000, China
5 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by SLACK, Inc. in Orthopedics
- Vol. 46 (1) , 59-63
Percutaneous Fixation of Levine–Edwards Type II Hangman's Fractures Under the Guidance of an Orthopedic Robot
There is no consensus regarding the optimal treatment for unstable hangman's fractures. Conservative treatment, although time-consuming and associated with complications such as nonunion, neck stiffness, and pseudarthrosis formation, is still preferred by many surgeons. With the development of minimally invasive techniques, surgical treatment is trending in recent years. We have proposed a minimally invasive, robot-assisted technique for the treatment of Levine–Edwards (L-E) type II hangman's fractures; this could improve the patients' quality of life. Five patients with L-E type II hangman's fractures were treated operatively initially. After closed reduction, the C2 pedicle screws were inserted percutaneously with the guidance of the orthopedic surgical robot. The positions of pedicle screws were verified by intraoperative 3-dimensional C-arm fluoroscopy. Regular follow-ups were performed to evaluate the radiological and functional outcomes. Postoperatively, all the fractures have healed with an average healing time of 3.5 months, the functional outcomes were satisfactory at last follow-up, and there was no neurovascular injury associated with this technique. The 3D-fluoroscopy–based, robot-assisted C2 pedicle screw fixation is a safe, precise, and feasible method for the initial treatment of L-E type II hangman's fractures. [Orthopedics. 20XX;XX(X):xx–xx.]
- 1 January 2023
- Published by SLACK, Inc. in Orthopedics
- Vol. 46 (1) , 59-63
Open AccessPercutaneous Fixation of Levine–Edwards Type II Hangman's Fractures Under the Guidance of an Orthopedic Robot
There is no consensus regarding the optimal treatment for unstable hangman's fractures. Conservative treatment, although time-consuming and associated with complications such as nonunion, neck stiffness, and pseudarthrosis formation, is still preferred by many surgeons. With the development of minimally invasive techniques, surgical treatment is trending in recent years. We have proposed a minimally invasive, robot-assisted technique for the treatment of Levine–Edwards (L-E) type II hangman's fractures; this could improve the patients' quality of life. Five patients with L-E type II hangman's fractures were treated operatively initially. After closed reduction, the C2 pedicle screws were inserted percutaneously with the guidance of the orthopedic surgical robot. The positions of pedicle screws were verified by intraoperative 3-dimensional C-arm fluoroscopy. Regular follow-ups were performed to evaluate the radiological and functional outcomes. Postoperatively, all the fractures have healed with an average healing time of 3.5 months, the functional outcomes were satisfactory at last follow-up, and there was no neurovascular injury associated with this technique. The 3D-fluoroscopy–based, robot-assisted C2 pedicle screw fixation is a safe, precise, and feasible method for the initial treatment of L-E type II hangman's fractures. [Orthopedics. 20XX;XX(X):xx–xx.]
- 8 March 2022
- Published by Springer Nature in Molecular Biotechnology
- Vol. 64 (8) , 928-935
Biodegradable Zn–2Ag–0.04Mg Alloy for Bone Regeneration In Vivo
To evaluate the bone regeneration capacity of Zn–2Ag–0.04Mg alloy scaffold in vivo. Zn, Zn–2Ag and Zn–2Ag–0.04Mg scaffolds were implanted in the femur of New Zealand rabbits, and the degradation of the scaffolds and the regeneration of the bone were observed at 6th week and 6th month. Two-dimensional and three-dimensional micro-CT results showed the new bone in Zn–2Ag–0.04Mg alloy scaffold group was significant more than Zn scaffold group, the bone volume in Zn–2Ag–0.04Mg was higher. Moreover, the osteogenic index in the Zn–2Ag–0.04Mg alloy scaffold group was also higher than Zn scaffold group. At 6th month, the scaffold of Zn–2Ag–0.04Mg was smaller than Zn group or Zn–2Ag group. HE staining of the liver, kidney, and heart did not detect any abnormalities, confirmed the biosafety of the Zn–2Ag–0.04Mg alloy scaffold. The Zn–Ag–0.04Mg alloy scaffold exhibits good biocompatibility and bone regeneration ability in vivo.
- 8 March 2022
- Published by Springer Nature in Molecular Biotechnology
- Vol. 64 (8) , 928-935
Biodegradable Zn–2Ag–0.04Mg Alloy for Bone Regeneration In Vivo
To evaluate the bone regeneration capacity of Zn–2Ag–0.04Mg alloy scaffold in vivo. Zn, Zn–2Ag and Zn–2Ag–0.04Mg scaffolds were implanted in the femur of New Zealand rabbits, and the degradation of the scaffolds and the regeneration of the bone were observed at 6th week and 6th month. Two-dimensional and three-dimensional micro-CT results showed the new bone in Zn–2Ag–0.04Mg alloy scaffold group was significant more than Zn scaffold group, the bone volume in Zn–2Ag–0.04Mg was higher. Moreover, the osteogenic index in the Zn–2Ag–0.04Mg alloy scaffold group was also higher than Zn scaffold group. At 6th month, the scaffold of Zn–2Ag–0.04Mg was smaller than Zn group or Zn–2Ag group. HE staining of the liver, kidney, and heart did not detect any abnormalities, confirmed the biosafety of the Zn–2Ag–0.04Mg alloy scaffold. The Zn–Ag–0.04Mg alloy scaffold exhibits good biocompatibility and bone regeneration ability in vivo.
- 7 July 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 148 (2) , 338e-339e
The Use of Nice Knots Cerclage to Aid Reduction and Fixation of Metacarpal Fractures
- 7 July 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 148 (2) , 338e-339e
The Use of Nice Knots Cerclage to Aid Reduction and Fixation of Metacarpal Fractures
- Open Access
- 15 June 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-7
Antegrade intramedullary fixation for adolescent fifth metacarpal neck fracture and its impact on epiphyseal growth
Background: Antegrade intramedullary nailing (AIMN) with Kirschner wire (K-wire) is a minimally invasive osteosynthesis technique. This procedure has been widely performed to treat the fifth metacarpal neck fracture (FMNF) in adults. This study was performed to determine whether using AIMN with a single K-wire to treat FMNF in adolescents would have good clinical and radiographic outcomes. Methods: In this retrospective study, 21 children (aged 11–16 years) with FMNF were treated using AIMN with a single K-wire from May 2017 to January 2020 in our hospital. Indications for intervention were severe displacement with malrotation deformity, apex dorsal angulation of greater than 40°, or both. Collected data included apex dorsal angulation, range of motion (ROM) in the fifth metacarpophalangeal (MCP) joint, Visual Analog Scale (VAS) for pain, grip strength, and Disabilities of the Arm, Shoulder, and Hand (DASH) score. Results: All patients were followed up for 12–24 months (average, 16.57 months), and all patients obtained anatomical reduction postoperatively. The healing time was 2.69 ± 0.83 months (range, 2–4 months). Average apex dorsal angulation was reduced significantly from 44.49°±2.64° to 15.74°±2.47° (P < 0.001). The average ROM in the MCP joint and apex dorsal angulation of the injured side were not significantly different from those of the uninjured side. The average DASH score was 1.76 ± 1.48 (range, 0–4), the mean VAS was 0.19 ± 0.60 (range, 0–2), and the mean grip strength was 91.55 %±4.52 % (range, 85–101 %). No secondary displacement, dysfunction, nonunion, infection, or osteonecrosis was observed during the follow-up. Although premature epiphyseal closure was found in one patient, no long-term clinical finding of angulation or shortening was identified. Conclusions: Antegrade intramedullary fixation with single K-wire was an effective and reliable technique that successfully resulted in good functional and cosmetic outcomes for treating adolescents with FMNF. The impact on the growth plate was low in this population given that most patients were at or approaching skeletal maturity. Level of evidence: Level IV.
- 15 June 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-7
Open AccessAntegrade intramedullary fixation for adolescent fifth metacarpal neck fracture and its impact on epiphyseal growth
Background: Antegrade intramedullary nailing (AIMN) with Kirschner wire (K-wire) is a minimally invasive osteosynthesis technique. This procedure has been widely performed to treat the fifth metacarpal neck fracture (FMNF) in adults. This study was performed to determine whether using AIMN with a single K-wire to treat FMNF in adolescents would have good clinical and radiographic outcomes. Methods: In this retrospective study, 21 children (aged 11–16 years) with FMNF were treated using AIMN with a single K-wire from May 2017 to January 2020 in our hospital. Indications for intervention were severe displacement with malrotation deformity, apex dorsal angulation of greater than 40°, or both. Collected data included apex dorsal angulation, range of motion (ROM) in the fifth metacarpophalangeal (MCP) joint, Visual Analog Scale (VAS) for pain, grip strength, and Disabilities of the Arm, Shoulder, and Hand (DASH) score. Results: All patients were followed up for 12–24 months (average, 16.57 months), and all patients obtained anatomical reduction postoperatively. The healing time was 2.69 ± 0.83 months (range, 2–4 months). Average apex dorsal angulation was reduced significantly from 44.49°±2.64° to 15.74°±2.47° (P < 0.001). The average ROM in the MCP joint and apex dorsal angulation of the injured side were not significantly different from those of the uninjured side. The average DASH score was 1.76 ± 1.48 (range, 0–4), the mean VAS was 0.19 ± 0.60 (range, 0–2), and the mean grip strength was 91.55 %±4.52 % (range, 85–101 %). No secondary displacement, dysfunction, nonunion, infection, or osteonecrosis was observed during the follow-up. Although premature epiphyseal closure was found in one patient, no long-term clinical finding of angulation or shortening was identified. Conclusions: Antegrade intramedullary fixation with single K-wire was an effective and reliable technique that successfully resulted in good functional and cosmetic outcomes for treating adolescents with FMNF. The impact on the growth plate was low in this population given that most patients were at or approaching skeletal maturity. Level of evidence: Level IV.
- Open Access
- 21 December 2020
- Published by Taylor & Francis in British Journal Of Neurosurgery
- Vol. 38 (2) , 249-255
Release, reduction, and fixation of one-stage posterior approach for basilar invagination with irreducible atlantoaxial dislocation
We evaluate the efficacy, safety and indications of single stage posterior release, reduction, and fixation of basilar invagination (BI) with irreducible atlantoaxial dislocation (IAAD). Seventeen ...
- 21 December 2020
- Published by Taylor & Francis in British Journal Of Neurosurgery
- Vol. 38 (2) , 249-255
Open AccessRelease, reduction, and fixation of one-stage posterior approach for basilar invagination with irreducible atlantoaxial dislocation
We evaluate the efficacy, safety and indications of single stage posterior release, reduction, and fixation of basilar invagination (BI) with irreducible atlantoaxial dislocation (IAAD). Seventeen ...
- Open Access
- 23 July 2020
- Published by Springer Nature in Research Square
Early Recurrent Dislocation and Dissociation of Bipolar Cup: Two Intricate Cases and Review of Literature.
Background: Bipolar hemiarthroplasty (BHA) is one of the best options to treat femoral neck fracture in elderly patients. However, the early dislocation problem also happens in the bipolar cup. Furthermore, BHA has a specific implant-related complication, namely bipolar cup dissociation, in which the femoral head dissociates from the polyethylene (PE) liner. Early dislocation and dissociation are relatively uncommon but devastating complications and almost always lead to reoperation with revision of the prosthesis. Dislocation and dissociation of the bipolar cup can be challenging to manage and easily turn to recurrent episodes in case of improper handling. We hope to find out the best strategy for treatment early recurrent dislocation and dissociation of the bipolar cup.Methods: We retrospectively reviewed 2 patients who had a history of early recurrent posterior dislocations following primary BHA from 2016 to 2019. What’s more, they had early recurrent bipolar cup dissociation during the attempt of closed reduction maneuvers within 3 months of the original surgery.Results: All the patients were treated with open reduction and revision of Bipolar hemiarthroplasty (BHA). One patient has a good outcome, and no recurrence of dislocation was recorded.Conclusion: Recognition of the risk of dislocation and dissociation of bipolar cup is essential to its prevention and treatment. Complete revision of bipolar parts and the femoral head may be the minimum solution necessary to avoid the early recurrence of bipolar cup dissociation. Further investigations are recommended to strengthen these results.
- 23 July 2020
- Published by Springer Nature in Research Square
Open AccessEarly Recurrent Dislocation and Dissociation of Bipolar Cup: Two Intricate Cases and Review of Literature.
Background: Bipolar hemiarthroplasty (BHA) is one of the best options to treat femoral neck fracture in elderly patients. However, the early dislocation problem also happens in the bipolar cup. Furthermore, BHA has a specific implant-related complication, namely bipolar cup dissociation, in which the femoral head dissociates from the polyethylene (PE) liner. Early dislocation and dissociation are relatively uncommon but devastating complications and almost always lead to reoperation with revision of the prosthesis. Dislocation and dissociation of the bipolar cup can be challenging to manage and easily turn to recurrent episodes in case of improper handling. We hope to find out the best strategy for treatment early recurrent dislocation and dissociation of the bipolar cup.Methods: We retrospectively reviewed 2 patients who had a history of early recurrent posterior dislocations following primary BHA from 2016 to 2019. What’s more, they had early recurrent bipolar cup dissociation during the attempt of closed reduction maneuvers within 3 months of the original surgery.Results: All the patients were treated with open reduction and revision of Bipolar hemiarthroplasty (BHA). One patient has a good outcome, and no recurrence of dislocation was recorded.Conclusion: Recognition of the risk of dislocation and dissociation of bipolar cup is essential to its prevention and treatment. Complete revision of bipolar parts and the femoral head may be the minimum solution necessary to avoid the early recurrence of bipolar cup dissociation. Further investigations are recommended to strengthen these results.
- Open Access
- 6 April 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background: This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods: Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results: No baseline statistical difference was observed between the groups (P > 0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08 ± 1.02 mm, 1.46 ± 0.84 ml, and 1.56 ± 0.32 min in the modified fixation group and 40.28 ± 8.52 mm, 12.02 ± 2.24 ml, and 5.08 ± 1.06 min in the conventional group. The difference between both groups was significant (P < 0.05). However, no significant difference between the two groups was observed in terms of the accuracy of pedicle screw placement (P > 0.05). Conclusions: The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value. Trial registration: Chinese Clinical Trial Registry: Registration number, ChiCTR1800016680; Registration Date, 15/06/2018.
- 6 April 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Open AccessMinimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background: This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods: Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results: No baseline statistical difference was observed between the groups (P > 0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08 ± 1.02 mm, 1.46 ± 0.84 ml, and 1.56 ± 0.32 min in the modified fixation group and 40.28 ± 8.52 mm, 12.02 ± 2.24 ml, and 5.08 ± 1.06 min in the conventional group. The difference between both groups was significant (P < 0.05). However, no significant difference between the two groups was observed in terms of the accuracy of pedicle screw placement (P > 0.05). Conclusions: The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value. Trial registration: Chinese Clinical Trial Registry: Registration number, ChiCTR1800016680; Registration Date, 15/06/2018.
- Open Access
- 20 February 2020
- Published by Springer Nature in Research Square
Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.
- 20 February 2020
- Published by Springer Nature in Research Square
Open AccessMinimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.
- Open Access
- 15 January 2020
- Published by Springer Nature in Research Square
Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.
- 15 January 2020
- Published by Springer Nature in Research Square
Open AccessMinimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.
- Open Access
- 12 December 2019
- Published by Springer Nature in Research Square
Minimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.
- 12 December 2019
- Published by Springer Nature in Research Square
Open AccessMinimally invasive versus conventional fixation of tracer in robot-assisted pedicle screw insertion surgery: a randomized control trial
Background This study evaluated the minimal invasiveness, safety, and accuracy of robot-assisted pedicle screw placement procedure using a modified tracer fixation device. Methods Patients were randomly assigned to conventional fixation group (25 patients) and modified fixation group (27 patients). Results No baseline statistical difference was observed between the groups ( P >0.05). The length of unnecessary incision, amount of bleeding, and fixation duration for tracer fixation respectively were 6.08±1.02 mm, 1.46±0.84 ml, and 1.56±0.32 min in the modified fixation group and 40.28±8.52 mm, 12.02±2.24 ml, and 5.08±1.06 min in the conventional group. The difference between both groups was significant ( P 0.05). Conclusions The modified minimally invasive procedure for tracer fixation results in minimal trauma and is simple, reliable, and highly safe. Additionally, the procedure does not compromise the accuracy of pedicle screw placement. Thus, it has great clinical applicable value.