Sigma-Delta Modulator with Thermoresistive Sensor Frequency Response
- 1 April 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 776-780
Abstract
In our previous paper we proposed feedback architecture with thermo-resistive sensor, based on thermal sigma-delta principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid velocity. This architecture uses 1-bit sigma-delta modulator in which considerable part of conversion functions is performed by a thermoresistive sensor. The sensor is modelled using electrical equivalence principle and the applied measure method is constant temperature. Now we present frequency response analysis and signal to noise ratio dependence on oversampling ratio for this architecture applied to thermal radiation measurementKeywords
This publication has 4 references indexed in Scilit:
- Implementation of a Feedback I2-Controlled Constant Temperature Environment Temperature MeterSensors, 2003
- A feedback I/sup 2/-controlled constant temperature solar radiation meterIEEE Transactions on Instrumentation and Measurement, 1998
- An overview of sigma-delta convertersIEEE Signal Processing Magazine, 1996
- A unity bit coding method by negative feedbackProceedings of the IEEE, 1963