Ligia S. Palma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ligia S. Palma has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Amauri Oliveira
Universidade Federal da Bahia, Brasil
4 shared publications - Raimundo Carlos Silvérios Freire
Department of Electrical Engineering, Federal University of Campina Grande, Campina Grande, Brazil
4 shared publications - Francisco F. Santos
Universidade Federal de Campina Grande, Unidade Acadêmica de Engenharia Elétrica, Campina Grande - PB, Brazil
2 shared publications - Georgina M. Freitas
Universidade Federal de Campina Grande, Unidade Acadêmica de Engenharia Elétrica, Campina Grande - PB, Brazil
2 shared publications - Hassan Aboushady
Sorbonne Université, CNRS, LIP6, Paris, France
2 shared publications - Sebastian Yuri Cavalcanti Catunda
Graduate Program in Electrical and Computer Engineering (PPgEEC), Federal University of Rio Grande do Norte (UFRN), Natal, Brazil
2 shared publications
Latest Publications
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1198-1201
Thermal Sigma-Delta Modulator: A Temperature Measurement Application
In this article, we describe a thermal sigma-delta converter implementation with thermoresistive sensor for temperature measurement. The sensor was integrated to a 1-bit, first order, sigma-delta modulator in the place of the integrator and sum blocks. Part of the modulator circuit was digitally implemented by a microcontroller, which was integrated to the analog circuit part and to the NTC thermoresistive sensor. A digital filter, formed by a second order Comb filter followed by a FIR filter, was used to obtain the estimated temperature.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1198-1201
Thermal Sigma-Delta Modulator: A Temperature Measurement Application
In this article, we describe a thermal sigma-delta converter implementation with thermoresistive sensor for temperature measurement. The sensor was integrated to a 1-bit, first order, sigma-delta modulator in the place of the integrator and sum blocks. Part of the modulator circuit was digitally implemented by a microcontroller, which was integrated to the analog circuit part and to the NTC thermoresistive sensor. A digital filter, formed by a second order Comb filter followed by a FIR filter, was used to obtain the estimated temperature.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-6
A Constant Temperature Thermoresistive Sigma-Delta Anemometer
In this paper we propose a feedback measurement system, with thermoresistive sensor, based on sigma-delta modulation. The system uses a one-bit sigma-delta modulator for which a considerable part of the conversion functions is performed by a thermoresistive sensor. The sensor is modelled using the power balance principle and the constant temperature measurement method is employed. This transducer architecture is able to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation and fluid velocity. This paper presents simulations and validates the structure of the sigma-delta converter as an anemometer. The advantage to directly convert physical quantities to digital, with the sensor as part of the A to D converter, makes possible the implementation of this measurement system in an integrated circuit. Another advantage of the IC implementation of this structure is the possibility to reduce noise interference due to discrete component connections in a printed circuit board.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-6
A Constant Temperature Thermoresistive Sigma-Delta Anemometer
In this paper we propose a feedback measurement system, with thermoresistive sensor, based on sigma-delta modulation. The system uses a one-bit sigma-delta modulator for which a considerable part of the conversion functions is performed by a thermoresistive sensor. The sensor is modelled using the power balance principle and the constant temperature measurement method is employed. This transducer architecture is able to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation and fluid velocity. This paper presents simulations and validates the structure of the sigma-delta converter as an anemometer. The advantage to directly convert physical quantities to digital, with the sensor as part of the A to D converter, makes possible the implementation of this measurement system in an integrated circuit. Another advantage of the IC implementation of this structure is the possibility to reduce noise interference due to discrete component connections in a printed circuit board.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Thermal Σ-Δ Modulator: Anemometer Performance Analysis
In this paper we propose a feedback architecture with a thermosensitive sensor, based on the thermal Σ-Δ principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid speed. This architecture uses a 1-bit Σ-Δ modulator for which a considerable part of the conversion functions is performed by a thermosensitive sensor. The sensor is modelled using the electrical equivalence principle and the constant temperature measurement method is applied. We present an analysis of the system performance, in terms of frequency response and system measurement resolution, of a 1-bit first-order Σ-Δ thermal modulator. It is shown that the system performance depends on the system oversampling ratio (OSR) and on the system transfer function pole and zero, which in turn, depends on the thermal and physical sensor characteristics and on the system operating conditions. This system is proposed as anemometer.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Thermal Σ-Δ Modulator: Anemometer Performance Analysis
In this paper we propose a feedback architecture with a thermosensitive sensor, based on the thermal Σ-Δ principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid speed. This architecture uses a 1-bit Σ-Δ modulator for which a considerable part of the conversion functions is performed by a thermosensitive sensor. The sensor is modelled using the electrical equivalence principle and the constant temperature measurement method is applied. We present an analysis of the system performance, in terms of frequency response and system measurement resolution, of a 1-bit first-order Σ-Δ thermal modulator. It is shown that the system performance depends on the system oversampling ratio (OSR) and on the system transfer function pole and zero, which in turn, depends on the thermal and physical sensor characteristics and on the system operating conditions. This system is proposed as anemometer.
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 776-780
Sigma-Delta Modulator with Thermoresistive Sensor Frequency Response
In our previous paper we proposed feedback architecture with thermo-resistive sensor, based on thermal sigma-delta principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid velocity. This architecture uses 1-bit sigma-delta modulator in which considerable part of conversion functions is performed by a thermoresistive sensor. The sensor is modelled using electrical equivalence principle and the applied measure method is constant temperature. Now we present frequency response analysis and signal to noise ratio dependence on oversampling ratio for this architecture applied to thermal radiation measurement
- 1 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 776-780
Sigma-Delta Modulator with Thermoresistive Sensor Frequency Response
In our previous paper we proposed feedback architecture with thermo-resistive sensor, based on thermal sigma-delta principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid velocity. This architecture uses 1-bit sigma-delta modulator in which considerable part of conversion functions is performed by a thermoresistive sensor. The sensor is modelled using electrical equivalence principle and the applied measure method is constant temperature. Now we present frequency response analysis and signal to noise ratio dependence on oversampling ratio for this architecture applied to thermal radiation measurement