The accuracy of non-invasively continuous total hemoglobin measurement by pulse CO-Oximetry undergoing acute normovolemic hemodilution and reinfusion of autologous blood
- 28 June 2014
- journal article
- Published by Springer Nature in Journal of Anesthesia
- Vol. 29 (1) , 29-34
Abstract
Non-invasively continuous total hemoglobin (SpHb) measurement has not been assessed adequately in acute bleeding and rapid blood transfusion during surgery. Thus, we have assessed the efficacy of SpHb during both acute normovolemic hemodilution (ANH) and autologous blood transfusion (ABT). Twenty-four patients undergoing urological and gynecological surgery were enrolled. ANH was induced by withdrawing blood of 800 g with simultaneous fluid administration. When surgical hemostasis was completed, collected blood was reinfused. Measurement of SpHb, perfusion index (PI) and real total Hb (tHb) were done before and after each 400 ml blood removal (−0, −400, −800 ml) and reinfusion (+0, +400, +800 ml). A Bland–Altman analysis for repeated measurements showed a bias (precision) g/dl of 1.12 (1.25), 1.43 (1.24) and 1.10 (1.23) for all data, during ANH and during ABT, respectively. Additionally, a bias (precision) increased with a reduction in tHb (g/dl): ≥10.0; 0.74 (1.30), 8.0–10.0; 1.15 (1.12) and r = 0.75, n = 228, p r = 0.38, n = 216, p r = 0.42, n = 23, p = 0.048 and r = 0.51, n = 22, p = 0.016, respectively). The present data suggest that SpHb may overestimate tHb during ANH and ABT. In addition, PI and tHb levels had an impact on the accuracy of SpHb measurements.Keywords
This publication has 18 references indexed in Scilit:
- Perfusion index and plethysmographic variability index in patients with interscalene nerve cathetersCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012
- Continuous Noninvasive Hemoglobin Monitoring During Complex Spine SurgeryAnesthesia & Analgesia, 2011
- The Accuracy of Noninvasive Hemoglobin Measurement by Multiwavelength Pulse Oximetry After Cardiac SurgeryAnesthesia & Analgesia, 2011
- Error in noninvasive spectrophotometric measurement of blood hemoglobin concentration under conditions of blood lossMedical Hypotheses, 2011
- Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin MeasurementAnesthesiology, 2011
- Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb StationThe American Journal of Surgery, 2011
- Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesiaActa Anaesthesiologica Scandinavica, 2009
- Use of acute normovolemic hemodilution in patients undergoing radical prostatectomyUrology, 2005
- Intraoperative Moderate Acute Normovolemic Hemodilution Associated with a Comprehensive Blood-Sparing Protocol in Off-Pump Coronary SurgeryAnesthesia & Analgesia, 2004
- Rheology of the microcirculation.2003