Hiroshi Hashimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hiroshi Hashimoto has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Junichi Saito
Department of Anesthesiology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
1 shared publication - Kazuyoshi Hirota
Working Group for Academic Promotion Project, Japan Federation of Anesthesiologists, Kobe, Japan
1 shared publication - Kazuyoshi Hirota
Department of Anesthesiology, University of Hirosaki School of Medicine, Hirosaki 036-8563, Japan
1 shared publication - Masafumi Oishi
Hirosaki University Graduate School of Medicine
1 shared publication - Masahiro Sawada
Department of Anesthesiology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
1 shared publication - Tomoyuki Kudo
Division of Intensive Care, Hirosaki University Hospital
1 shared publication
Latest Publications
- 28 June 2014
- Published by Springer Nature in Journal of Anesthesia
- Vol. 29 (1) , 29-34
The accuracy of non-invasively continuous total hemoglobin measurement by pulse CO-Oximetry undergoing acute normovolemic hemodilution and reinfusion of autologous blood
Non-invasively continuous total hemoglobin (SpHb) measurement has not been assessed adequately in acute bleeding and rapid blood transfusion during surgery. Thus, we have assessed the efficacy of SpHb during both acute normovolemic hemodilution (ANH) and autologous blood transfusion (ABT). Twenty-four patients undergoing urological and gynecological surgery were enrolled. ANH was induced by withdrawing blood of 800 g with simultaneous fluid administration. When surgical hemostasis was completed, collected blood was reinfused. Measurement of SpHb, perfusion index (PI) and real total Hb (tHb) were done before and after each 400 ml blood removal (−0, −400, −800 ml) and reinfusion (+0, +400, +800 ml). A Bland–Altman analysis for repeated measurements showed a bias (precision) g/dl of 1.12 (1.25), 1.43 (1.24) and 1.10 (1.23) for all data, during ANH and during ABT, respectively. Additionally, a bias (precision) increased with a reduction in tHb (g/dl): ≥10.0; 0.74 (1.30), 8.0–10.0; 1.15 (1.12) and r = 0.75, n = 228, p r = 0.38, n = 216, p r = 0.42, n = 23, p = 0.048 and r = 0.51, n = 22, p = 0.016, respectively). The present data suggest that SpHb may overestimate tHb during ANH and ABT. In addition, PI and tHb levels had an impact on the accuracy of SpHb measurements.
- 28 June 2014
- Published by Springer Nature in Journal of Anesthesia
- Vol. 29 (1) , 29-34
The accuracy of non-invasively continuous total hemoglobin measurement by pulse CO-Oximetry undergoing acute normovolemic hemodilution and reinfusion of autologous blood
Non-invasively continuous total hemoglobin (SpHb) measurement has not been assessed adequately in acute bleeding and rapid blood transfusion during surgery. Thus, we have assessed the efficacy of SpHb during both acute normovolemic hemodilution (ANH) and autologous blood transfusion (ABT). Twenty-four patients undergoing urological and gynecological surgery were enrolled. ANH was induced by withdrawing blood of 800 g with simultaneous fluid administration. When surgical hemostasis was completed, collected blood was reinfused. Measurement of SpHb, perfusion index (PI) and real total Hb (tHb) were done before and after each 400 ml blood removal (−0, −400, −800 ml) and reinfusion (+0, +400, +800 ml). A Bland–Altman analysis for repeated measurements showed a bias (precision) g/dl of 1.12 (1.25), 1.43 (1.24) and 1.10 (1.23) for all data, during ANH and during ABT, respectively. Additionally, a bias (precision) increased with a reduction in tHb (g/dl): ≥10.0; 0.74 (1.30), 8.0–10.0; 1.15 (1.12) and r = 0.75, n = 228, p r = 0.38, n = 216, p r = 0.42, n = 23, p = 0.048 and r = 0.51, n = 22, p = 0.016, respectively). The present data suggest that SpHb may overestimate tHb during ANH and ABT. In addition, PI and tHb levels had an impact on the accuracy of SpHb measurements.