Feasibility and Acute Safety Study of Radiofrequency Energy Delivery to the Vena Caval Wall Via an Inferior Vena Cava Filter in Swine
- 12 June 2019
- journal article
- research article
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 2 (3)
Abstract
Retrievable inferior vena cava (IVC) filters are self-expanding metallic devices implanted in the IVC to prevent migration of thrombi from the deep veins of the legs and pelvis to the lungs. The risk of complications from the filters increases with duration of implantation, but retrieval may be difficult due to intimal hyperplasia around the components of the filter. In this study, the potential for delivery of radiofrequency (RF) energy to the IVC wall via the filter was investigated. IVC filters were deployed in four swine while attached to a snare connected to a 480 kHz RF generator. Energy ranging from 0 to 48 kJ was applied via the filter followed by resheathing and withdrawal of the filter while connected to a force measurement device. Resheathing forces for the zero-energy cohort and pooled data from the 6–24 kJ cohorts were 4.50 ± 0.70 N and 4.50 ± 0.75 N, respectively. Petechial hemorrhages and variable nonocclusive thrombi were noted in some cohorts including the zero-energy cohort, consistent with delivery and acute retrieval of an IVC filter. Histologically, the extent of RF-induced injury was subtle at 6 kJ with focal areas of homogenized collagen while the 12 kJ cohort showed segmental tissue charring with coagulation necrosis, which was more extensive for the 24 kJ cohort. The 48 kJ energy caused more extensive and nontarget organ damage. The study demonstrated feasibility of delivery of RF to the IVC wall via a deployed filter, supporting further study of the ability of local RF heating of the IVC wall to inhibit the neointimal hyperplasia or as an aid in retrieval.Keywords
This publication has 16 references indexed in Scilit:
- Decreasing Utilization of Inferior Vena Cava Filters in Post-FDA Warning Era: Insights From 2005 to 2014 Nationwide Inpatient SampleJournal of the American College of Radiology, 2017
- Laser-Assisted Removal of Embedded Vena Cava FiltersChest, 2017
- Complex Inferior Vena Cava Filter Removal with a Metallic Bladed-Tip Mechanical SheathJournal of Vascular and Interventional Radiology, 2016
- A 16-F Sheath with Endobronchial Forceps Improves Reported Retrieval Success of Long-Dwelling “Closed Cell” Inferior Vena Cava Filter DesignsJournal of Vascular and Interventional Radiology, 2016
- Retrieval of Inferior Vena Cava Filters With Prolonged Dwell TimeJAMA Internal Medicine, 2015
- Retrieval of Tip-embedded Inferior Vena Cava Filters by Using the Endobronchial Forceps Technique: Experience at a Single InstitutionRadiology, 2015
- The CIRSE Retrievable IVC Filter Registry: Retrieval Success Rates in PracticeCardioVascular and Interventional Radiology, 2015
- Systematic Review of the Use of Retrievable Inferior Vena Cava FiltersJournal of Vascular and Interventional Radiology, 2011
- Photothermal Ablation with the Excimer Laser Sheath Technique for Embedded Inferior Vena Cava Filter Removal: Initial Results from a Prospective StudyJournal of Vascular and Interventional Radiology, 2011
- Development of a Research Agenda for Inferior Vena Cava Filters: Proceedings from a Multidisciplinary Research Consensus PanelJournal of Vascular and Interventional Radiology, 2009