Ivane Bakhutashvili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ivane Bakhutashvili has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Bradford J. Wood
Center for Interventional Oncology, NCI, NIH, Bethesda, MD, USA
3 shared publications - Baris Turkbey
Molecular Imaging Branch, National Cancer Institute, National Institutes of Health, Bethesda, MD, USA
2 shared publications - John W. Karanian
Center for Interventional Oncology, National Institutes of Health Clinical Center, Bethesda, MD, USA
2 shared publications - Juan A. Esparza-Trujillo
Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, USA
2 shared publications - Ming Li
Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, USA
2 shared publications - Peter L. Choyke
National Cancer Institute 1 Molecular Imaging Branch, Center for Cancer Research , Bethesda, Maryland
2 shared publications
Latest Publications
- Open Access
- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (02) , 025001-12
HoloLens augmented reality system for transperineal free-hand prostate procedures
Prostate cancer is the second leading cause of cancer death among American men.1 The two principal approaches for the diagnosis of prostate cancer are transrectal and transperineal (TP) biopsy.2 Similarities in efficacy between the two biopsy approaches have been reported.3 However, the TP approach results in a markedly lower risk of sepsis.4
- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (02) , 025001-12
Open AccessHoloLens augmented reality system for transperineal free-hand prostate procedures
Prostate cancer is the second leading cause of cancer death among American men.1 The two principal approaches for the diagnosis of prostate cancer are transrectal and transperineal (TP) biopsy.2 Similarities in efficacy between the two biopsy approaches have been reported.3 However, the TP approach results in a markedly lower risk of sepsis.4
- 21 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (9) , 1439-1447
Electromagnetic Tracking and Optical Molecular Imaging Guidance for Liver Biopsy and Point-of-Care Tissue Assessment in Phantom and Woodchuck Hepatocellular Carcinoma
Purpose To evaluate an integrated liver biopsy platform that combined CT image fusion, electromagnetic (EM) tracking, and optical molecular imaging (OMI) of indocyanine green (ICG) to target hepatocellular carcinoma (HCC) lesions and a point-of-care (POC) OMI to assess biopsy cores, all based on tumor retention of ICG compared to normal liver, in phantom and animal model. Material A custom CT image fusion and EM-tracked guidance platform was modified to integrate the measurement of ICG fluorescence intensity signals in targeted liver tissue with an OMI stylet or a POC OMI system. Accuracy was evaluated in phantom and a woodchuck with HCC, 1 day after administration of ICG. Fresh biopsy cores and paraffin-embedded formalin-fixed liver tissue blocks were evaluated with the OMI stylet or POC system to identify ICG fluorescence signal and ICG peak intensity. Results The mean distance between the initial guided needle delivery location and the peak ICG signal was 5.0 ± 4.7 mm in the phantom. There was complete agreement between the reviewers of the POC-acquired ICG images, cytology, and histopathology in differentiating HCC-positive from HCC-negative biopsy cores. The peak ICG fluorescence intensity signal in the ex vivo liver blocks was 39 ± 12 and 281 ± 150 for HCC negative and HCC positive, respectively. Conclusion Biopsy guidance with fused CT imaging, EM tracking, and ICG tracking with an OMI stylet to detect HCC is feasible. Immediate assessment of ICG uptake in biopsy cores with the POC OMI system is feasible and correlates with the presence of HCC in the tissue.
- 21 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (9) , 1439-1447
Electromagnetic Tracking and Optical Molecular Imaging Guidance for Liver Biopsy and Point-of-Care Tissue Assessment in Phantom and Woodchuck Hepatocellular Carcinoma
Purpose To evaluate an integrated liver biopsy platform that combined CT image fusion, electromagnetic (EM) tracking, and optical molecular imaging (OMI) of indocyanine green (ICG) to target hepatocellular carcinoma (HCC) lesions and a point-of-care (POC) OMI to assess biopsy cores, all based on tumor retention of ICG compared to normal liver, in phantom and animal model. Material A custom CT image fusion and EM-tracked guidance platform was modified to integrate the measurement of ICG fluorescence intensity signals in targeted liver tissue with an OMI stylet or a POC OMI system. Accuracy was evaluated in phantom and a woodchuck with HCC, 1 day after administration of ICG. Fresh biopsy cores and paraffin-embedded formalin-fixed liver tissue blocks were evaluated with the OMI stylet or POC system to identify ICG fluorescence signal and ICG peak intensity. Results The mean distance between the initial guided needle delivery location and the peak ICG signal was 5.0 ± 4.7 mm in the phantom. There was complete agreement between the reviewers of the POC-acquired ICG images, cytology, and histopathology in differentiating HCC-positive from HCC-negative biopsy cores. The peak ICG fluorescence intensity signal in the ex vivo liver blocks was 39 ± 12 and 281 ± 150 for HCC negative and HCC positive, respectively. Conclusion Biopsy guidance with fused CT imaging, EM tracking, and ICG tracking with an OMI stylet to detect HCC is feasible. Immediate assessment of ICG uptake in biopsy cores with the POC OMI system is feasible and correlates with the presence of HCC in the tissue.
- 12 June 2019
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 2 (3)
Feasibility and Acute Safety Study of Radiofrequency Energy Delivery to the Vena Caval Wall Via an Inferior Vena Cava Filter in Swine
Retrievable inferior vena cava (IVC) filters are self-expanding metallic devices implanted in the IVC to prevent migration of thrombi from the deep veins of the legs and pelvis to the lungs. The risk of complications from the filters increases with duration of implantation, but retrieval may be difficult due to intimal hyperplasia around the components of the filter. In this study, the potential for delivery of radiofrequency (RF) energy to the IVC wall via the filter was investigated. IVC filters were deployed in four swine while attached to a snare connected to a 480 kHz RF generator. Energy ranging from 0 to 48 kJ was applied via the filter followed by resheathing and withdrawal of the filter while connected to a force measurement device. Resheathing forces for the zero-energy cohort and pooled data from the 6–24 kJ cohorts were 4.50 ± 0.70 N and 4.50 ± 0.75 N, respectively. Petechial hemorrhages and variable nonocclusive thrombi were noted in some cohorts including the zero-energy cohort, consistent with delivery and acute retrieval of an IVC filter. Histologically, the extent of RF-induced injury was subtle at 6 kJ with focal areas of homogenized collagen while the 12 kJ cohort showed segmental tissue charring with coagulation necrosis, which was more extensive for the 24 kJ cohort. The 48 kJ energy caused more extensive and nontarget organ damage. The study demonstrated feasibility of delivery of RF to the IVC wall via a deployed filter, supporting further study of the ability of local RF heating of the IVC wall to inhibit the neointimal hyperplasia or as an aid in retrieval.
- 12 June 2019
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 2 (3)
Feasibility and Acute Safety Study of Radiofrequency Energy Delivery to the Vena Caval Wall Via an Inferior Vena Cava Filter in Swine
Retrievable inferior vena cava (IVC) filters are self-expanding metallic devices implanted in the IVC to prevent migration of thrombi from the deep veins of the legs and pelvis to the lungs. The risk of complications from the filters increases with duration of implantation, but retrieval may be difficult due to intimal hyperplasia around the components of the filter. In this study, the potential for delivery of radiofrequency (RF) energy to the IVC wall via the filter was investigated. IVC filters were deployed in four swine while attached to a snare connected to a 480 kHz RF generator. Energy ranging from 0 to 48 kJ was applied via the filter followed by resheathing and withdrawal of the filter while connected to a force measurement device. Resheathing forces for the zero-energy cohort and pooled data from the 6–24 kJ cohorts were 4.50 ± 0.70 N and 4.50 ± 0.75 N, respectively. Petechial hemorrhages and variable nonocclusive thrombi were noted in some cohorts including the zero-energy cohort, consistent with delivery and acute retrieval of an IVC filter. Histologically, the extent of RF-induced injury was subtle at 6 kJ with focal areas of homogenized collagen while the 12 kJ cohort showed segmental tissue charring with coagulation necrosis, which was more extensive for the 24 kJ cohort. The 48 kJ energy caused more extensive and nontarget organ damage. The study demonstrated feasibility of delivery of RF to the IVC wall via a deployed filter, supporting further study of the ability of local RF heating of the IVC wall to inhibit the neointimal hyperplasia or as an aid in retrieval.
- Open Access
- 29 November 2018
- Published by MDPI AG in Journal of Imaging
- Vol. 4 (12) , 140
MRI Robot for Prostate Focal Laser Ablation: An Ex Vivo Study in Human Prostate
Purpose: A novel grid-template-mimicking MR-compatible robot was developed for in-gantry MRI-guided focal laser ablation of prostate cancer. Method: A substantially compact robot was designed and prototyped to meet in-gantry lithotomy ergonomics and allow for accommodation in the perineum. The controller software was reconfigured and integrated with the custom-designed navigation and multi-focal ablation software. Three experiments were conducted: (1) free space accuracy test; (2) phantom study under computed tomography (CT) guidance for image-guided accuracy test and overall workflow; and (3) magnetic resonance imaging (MRI)-guided focal laser ablation of an ex vivo prostate. The free space accuracy study included five targets that were selected across the workspace. The robot was then commanded five times to each target. The phantom study used a gel phantom made with color changing thermos-chromic ink, and four spherical metal fiducials were deployed with the robot. Then, laser ablation was applied, and the phantom was sliced for gross observation. For an MR-guided ex vivo test, a prostate from a donor who died of prostate cancer was obtained and multi-focally ablated using the system within the MRI gantry. The tissue was sliced after ablation for validation. Results: free-space accuracy was 0.38 ± 0.27 mm. The overall system targeting accuracy under CT guidance (including robot, registration, and insertion error) was 2.17 ± 0.47 mm. The planned ablation zone was successfully covered in both acrylamide gel phantom and in human prostate tissue. Conclusions: The new robot can accurately facilitate fiber targeting for MR-guided focal laser ablation of targetable prostate cancer.
- 29 November 2018
- Published by MDPI AG in Journal of Imaging
- Vol. 4 (12) , 140
Open AccessMRI Robot for Prostate Focal Laser Ablation: An Ex Vivo Study in Human Prostate
Purpose: A novel grid-template-mimicking MR-compatible robot was developed for in-gantry MRI-guided focal laser ablation of prostate cancer. Method: A substantially compact robot was designed and prototyped to meet in-gantry lithotomy ergonomics and allow for accommodation in the perineum. The controller software was reconfigured and integrated with the custom-designed navigation and multi-focal ablation software. Three experiments were conducted: (1) free space accuracy test; (2) phantom study under computed tomography (CT) guidance for image-guided accuracy test and overall workflow; and (3) magnetic resonance imaging (MRI)-guided focal laser ablation of an ex vivo prostate. The free space accuracy study included five targets that were selected across the workspace. The robot was then commanded five times to each target. The phantom study used a gel phantom made with color changing thermos-chromic ink, and four spherical metal fiducials were deployed with the robot. Then, laser ablation was applied, and the phantom was sliced for gross observation. For an MR-guided ex vivo test, a prostate from a donor who died of prostate cancer was obtained and multi-focally ablated using the system within the MRI gantry. The tissue was sliced after ablation for validation. Results: free-space accuracy was 0.38 ± 0.27 mm. The overall system targeting accuracy under CT guidance (including robot, registration, and insertion error) was 2.17 ± 0.47 mm. The planned ablation zone was successfully covered in both acrylamide gel phantom and in human prostate tissue. Conclusions: The new robot can accurately facilitate fiber targeting for MR-guided focal laser ablation of targetable prostate cancer.