Abstract
We present a systematic theoretical and experimental investigation on the accuracy of thermal diffusivity α and thermal effusivity e of liquids measured by the photopyroelectric (PPE) method in back-detection configuration (BPPE). Special cases corresponding to different cell structures are analyzed in terms of error determination of α and e for water and ethylene glycol. We propose a new normalization procedure allowing for estimation of these parameters with accuracy of 2% on α and 5% on e over extended frequency range. The normalization eliminates the frequency-dependent influence of the transducer impedance and associated electronics, reduces the errors due to coupling fluid between cell components, and reduces the number of temperature-dependent parameters that must be known in order to characterize the sample. Technical solutions for improving the performances are suggested. Another goal of the study was to demonstrate the possibility of the BPPE method to yield small variations of thermal parameters as a function of temperature. We found good agreement with the literature data for the temperature coefficients for water and for ethylene glycol, between 20 and 60 °C. The special case implying the normalization to a reference material and with a glass substrate for the pyroelectric sensor is shown to be the best adapted to the determination of both thermal parameters and of their temperature dependence.
Keywords
This publication has 19 references indexed in Scilit:
- Thermal diffusivity measurements in the photoacoustic open-cell configuration using simple signal normalization techniquesJournal of Applied Physics, 2001
- Simple, accurate, and precise measurements of thermal diffusivity in liquids using a thermal-wave cavityReview of Scientific Instruments, 2001
- Self-normalized photothermal techniques for thermal diffusivity measurementsJournal of Applied Physics, 2000
- Photoacoustic and photopyroelectric approach to calorimetric studiesThermochimica Acta, 1997
- Thermal-wave resonator cavityReview of Scientific Instruments, 1995
- Thermal wave photopyroelectric characterization of advanced materials: State of the artCritical Reviews in Solid State and Materials Sciences, 1993
- High-resolution simultaneous photothermal measurements of thermal parameters at a phase transition with the photopyroelectric techniqueJournal of Applied Physics, 1992
- Pyroelectric sensors for the photothermal analysis of condensed phasesFerroelectrics, 1991
- Inverse Photopyroelectric Detection MethodPhysica Status Solidi (a), 1990
- Thermal diffusivity measurements of thin films with a pyroelectric calorimeterApplied Physics A, 1985