Safety and diagnostic image quality of iopromide: results of a large non-interventional observational study of European and Asian patients (IMAGE)
Authors:
- 1 March 2012
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (2) , 179-186
Abstract
Background Direct comparison of different image reconstruction parameters to detect pulmonary embolism (PE) using 64-slice multidetector-row computed tomography (MDCT) is absent and the most accurate image reconstruction parameters have not yet been proven. Purpose To compare different image reconstruction parameters for detecting PE using 64-slice MDCT in patients suspected of having an acute PE. Material and Methods Forty patients who underwent pulmonary CT angiography with 64-slice MDCT for a suspected PE were included. Different image reconstruction parameters were used for each patient: axial and coronal images with slice thicknesses of 0.625 mm, 1.3 mm, and 2.5 mm and axial maximum intensity projection (MIP) images with slab thicknesses of 1.3 mm, 2.5 mm, and 5 mm. Four experienced radiologists reviewed the images. The diagnosis of a PE was based on consensus review of axial 0.625 mm slice thickness images by two chest radiologists with allowing multiplanar reconstruction. Accuracy and reproducibility (kappa value) were evaluated. Results In 15 of 40 patients, a PE was diagnosed. For detecting lobar PEs, axial images with a slice thickness of 1.25 mm and all coronal re-formatted images showed comparable results to axial images with a slice thickness of 0.625 mm. For detecting segmental PEs, axial images with a slice thickness of 1.25 mm and coronal images with a slice thickness of 0.625 mm re-formatted images showed comparable results to axial images of a slice thickness of 0.625 mm. For detecting subsegmental PEs, axial images with a slice thickness of 0.625 mm showed the highest sensitivity. Better reproducibility was obtained when the thinner slice thickness reconstructions were in axial and coronal images. However, reproducibility of MIP images with slab thicknesses of 2.5 mm and 5 mm was similar for detecting segmental and subsegmental PEs. Conclusion Thin-slice reconstruction of less than 1 mm is mandatory for visualization of PE at the subsegmental level.Keywords
This publication has 22 references indexed in Scilit:
- Prevalence of acute reactions to iopromide: postmarketing surveillance study of 74,717 patientsActa Radiologica, 2008
- Safety of iobitridol in the general population and at-risk patientsEuropean Radiology, 2006
- Universal Use of Nonionic Iodinated Contrast Medium for CT: Evaluation of Safety in a Large Urban Teaching HospitalAmerican Journal of Roentgenology, 2005
- Results of the safety and efficacy of iobitridol in more than 61,000 patientsEuropean Radiology, 2003
- Nonfatal adverse reactions to iodinated contrast media: spontaneous reporting to the U.S. Food and Drug Administration, 1978-1994.Radiology, 1997
- Adverse events with radiographic contrast agents: results of the SCVIR Contrast Agent Registry.Radiology, 1997
- Reports on contrast media reactions: analysis of data from reports to the U.S. Food and Drug Administration.Radiology, 1997
- Evaluation of the clinical safety and efficacy of iobitridol (Xenetix) in intravenous urographyEuropean Journal of Radiology, 1996
- Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.Radiology, 1990
- The RACR Survey of Intravenous Contrast Media Reactions Final ReportAustralasian Radiology, 1988