Development of Ta-Based Superconducting Tunnel Junction X-Ray Detector Arrays
Authors:
- 28 December 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 2400504
Abstract
We are developing new Ta-based superconducting tunnel junction (STJ) X-ray detectors for high-resolution soft X-ray spectroscopy at synchrotrons. STJ detectors combine the high-energy resolution of cryogenic detectors with the high count rate capabilities of athermal devices and the high efficiencies of solid state detectors, which increases the sensitivity for material analysis by fluorescence-detected X-ray absorption spectroscopy. Our STJ detectors are fabricated using thick, high-Z Ta absorber films that enhance quantum efficiency and spectral purity, and extend operational range to several keV compared with earlier Nb-based STJs. They offer an energy resolution of ~ 5 to 10 eV FWHM for soft X-rays up to ~1 keV, and count rates of several 1000 counts/s per detector pixel. For increased solid angle coverage, we have fabricated 36- and 112-pixel Ta-based STJ detector arrays with total areas of 1.4 and 4.5 mm 2 , respectively. The 208 × 208 μm 2 pixels have an energy resolution between 6.8 and 7.6 eV FWHM at 525 eV with a low-energy shoulder, and their responsivity is uniform to within 2% across the array. Here we discuss the performance of the array in the context of synchrotron science.Keywords
Funding Information
- U.S. Department of Energy (DE-SC0004359, DE-SC0006214)
This publication has 14 references indexed in Scilit:
- Praseodymium valence determination in Lu2SiO5, Y2SiO5, and Lu3Al5O12 scintillators by x-ray absorption spectroscopyApplied Physics Letters, 2012
- New Developments in Superconducting Tunnel Junction X-Ray Spectrometers for Synchrotron ScienceJournal of Low Temperature Physics, 2012
- Preamplifier development for superconducting tunnel junction array X-ray detector electronics2010
- Chromium oxidation by manganese (hydr)oxides in a California aquiferApplied Geochemistry, 2010
- Cryogenic X-ray detectors for synchrotron scienceJournal of Synchrotron Radiation, 2006
- Direct Observation of Nitrogen Location in Molecular Beam Epitaxy Grown Nitrogen-Doped ZnOPhysical Review Letters, 2006
- Sensitivity and S/N-ratio of superconducting high-resolution X-ray spectrometersIEEE Transactions on Applied Superconductivity, 2005
- Improved energy resolution of x-ray single photon imaging spectrometers using superconducting tunnel junctionsJournal of Applied Physics, 2001
- A superconducting tunnel junction x-ray detector with performance limited by statistical effectsApplied Physics Letters, 1998
- Single photon imaging X-ray spectrometers using low noise current preamplifiers with dc voltage biasIEEE Transactions on Applied Superconductivity, 1997