Immediate Change in Suprarenal Neck Angulation After Endovascular Aneurysm Repair
- 15 June 2015
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 22 (4) , 613-619
Abstract
Purpose: To compare the immediate suprarenal neck angulation change between the Ovation stent-graft, with its inflatable sealing rings, and a stent-graft with a conventional sealing mechanism. Methods: A case-control study was conducted in which 30 consecutive patients (mean age 67 years; all men) with abdominal aortic aneurysm (AAA) treated with the Ovation stent-graft (group O) were retrospectively compared with 24 patients (mean age 77 years; all men) contemporaneously treated with the Endurant stent-graft (group E) at 3 high-volume tertiary vascular centers. The variables recorded were the aortic neck length, preoperative and postoperative angulation, minimum and maximum diameters of the infrarenal neck, as well as the maximum AAA diameter. All patients had undergone preoperative and postoperative (within 30 days) computed tomographic angiography. Multiple regression analysis compared the relative contribution to neck angulation change of each geometric parameter and the type of endograft. Data are presented as the mean ± standard deviation. Results: The mean preoperative suprarenal neck angulation in group O was 23.2°±18.0° compared with 23.8°±22.9° in group E (t test, p=0.91). The neck lengths were 29.2±14.6 and 23.2±11.0 mm in groups O and E, respectively (p=0.1). Similarly, the minimum and maximum neck diameters were 22.4±2.6 and 25±3.5 mm, respectively, in group O vs 23.3±3.6 mm and 27.0±5.7 mm, respectively, in group E (p=0.3 and 0.12, respectively). The maximum transverse diameters of the AAA in the 2 groups were comparable, that is, 57.0±9.0 mm in group O vs 53.2±11.1 mm in group E (p=0.17). The Ovation stent-graft caused greater decrease in the aortic neck angulation postoperatively compared with the Endurant device (13.2°±16.1° vs 6.1°±5.9°, p=0.04). Multiple regression analysis revealed that preoperative neck angulation (β coefficient 0.37, p<0.001) and the type of endograft (β coefficient −7.91, p=0.01) had significant influence on the postoperative neck angulation change. The intraclass correlation coefficient ranged from 0.951 to 0.990 for the preoperative measurements and from 0.911 to 0.999 for the postoperative measurements for each examiner or the total of estimates at the measurement time points. Conclusion: The Ovation stent-graft induces greater postoperative reduction in the AAA neck angulation compared to an endograft with stent-supported graft seal. Expanded research to infrarenal angle as well to greater angles and correlation to clinical events is justified.Keywords
This publication has 24 references indexed in Scilit:
- One-year outcomes from an international study of the Ovation Abdominal Stent Graft System for endovascular aneurysm repairJournal of Vascular Surgery, 2014
- The influence of thrombus, calcification, angulation, and tortuosity of attachment sites on the time to the first graft-related complication after endovascular aneurysm repairJournal of Vascular Surgery, 2011
- Severe Proximal Aneurysm Neck Angulation: Early Results Using the Endurant Stentgraft SystemEuropean Journal of Vascular and Endovascular Surgery, 2011
- Influence of Different Self-Expanding Stent-Graft Types on Remodeling of the Aortic Neck After Endovascular Aneurysm RepairJournal of Endovascular Therapy, 2010
- Aortic Neck Angulations Decrease During and After Endovascular Aneurysm RepairJournal of Endovascular Therapy, 2010
- A Computational Study of the Magnitude and Direction of Migration Forces in Patient-specific Abdominal Aortic Aneurysm Stent-GraftsEuropean Journal of Vascular and Endovascular Surgery, 2010
- Impact of calcification and intraluminal thrombus on the computed wall stresses of abdominal aortic aneurysmJournal of Vascular Surgery, 2008
- Aortic Neck Dilatation and Endograft Migration Are Correlated With Self-Expanding EndograftsJournal of Endovascular Therapy, 2007
- Absence of proximal neck dilatation and graft migration after endovascular aneurysm repair with balloon-expandable stent-based endograftsJournal of Vascular Surgery, 2005
- Flow Visualization in a Model of a Bifurcated Stent-GraftJournal of Endovascular Therapy, 2005