Thermoforming time variability in clear aligner fabrication: A pilot in vitro study
Open Access
- 4 August 2026
- journal article
- Published by Scientific Scholar in APOS Trends in Orthodontics
- Vol. 16, 260-266
Abstract
Objectives: Thermoforming time is a key process parameter in the fabrication of clear orthodontic aligners. Manufacturer-recommended heating durations, however, may not reflect changes in heating time during consecutive thermoforming cycles. This study investigated variations in thermoforming time across repeated forming cycles to support optimization of in-house clear aligner fabrication protocols. Material and Methods: In this in vitro study, 100 Zendura FLX thermoplastic sheets (0.76 mm) were thermoformed in five independent sessions, each comprising 20 consecutive cycles, using a Drufomat Scan pressure-forming unit initiated from a cold-start condition. Heating was manually terminated at a standardized sheet deflection of 16 mm, based on preliminary pilot testing, monitored using a parallel laser guidance system. Heating duration was recorded for each cycle. Data were analyzed using a linear mixed-effects model with Bonferroni-adjusted post hoc comparisons. Thermal stabilization was defined as the earliest cycle at which no significant difference in heating time was observed between consecutive cycles ( p > 0.05). Linear regression analysis was applied to characterize heating-time reduction before stabilization. Results: Heating duration ranged from 60.2 to 111.6 s across all cycles. Heating time decreased markedly during the first five cycles and stabilized from the sixth cycle onward ( p > 0.05). During the steady-state phase, the mean heating time was 64.41 ± 3.06 s, remaining significantly longer than the manufacturer-recommended value of 50 s ( p < 0.0001). Linear regression showed a significant reduction in heating time during the pre-stabilization phase (8.56 s/cycle; R 2 = 0.77). Conclusion: Thermoforming time decreased during early fabrication cycles due to cumulative heat retention within the thermoforming unit. Even after thermal stabilization, heating durations exceeded manufacturer-recommended values. These findings indicate that preset heating times should be regarded as reference values and experimentally adjusted according to material and machine-specific behavior.Keywords
This publication has 16 references indexed in Scilit:
- The thickness and gap width of aligners made of three types of thermoforming materials: An in-vitro studySeminars in Orthodontics, 2024
- Effect of thermomechanical ageing on force transmission by orthodontic aligners made of different thermoformed materials: An experimental studyOrthodontics & Craniofacial Research, 2024
- Thickness Variations of Thermoformed and 3D-Printed Clear AlignersActa Stomatologica Croatica, 2024
- Manufacture and use of In-house clear aligners using digital technologyJournal of Korean Dental Association, 2024
- Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro studyClinical Oral Investigations, 2024
- Differential Stability of One-layer and Three-layer Orthodontic Aligner Blends under Thermocycling: Implications for Clinical DurabilityActa Stomatologica Croatica, 2023
- Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometerScientific Reports, 2023
- Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolutionJournal of Medical Imaging, 2022
- Dynamic mechanical and thermal properties of clear aligners after thermoforming and agingProgress in Orthodontics, 2021
- Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical studyProgress in Orthodontics, 2019