Comparison of Zr, Bi, Ti, and Ga as Metal Contacts in Inorganic Perovskite CsPbBr₃ Gamma-Ray Detector
Open Access
- 20 August 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (10) , 2255-2262
Abstract
We report a performance comparison of Zr, Bi, Ti, and Ga as metal contacts on solution-grown CsPbBr3 single crystal gamma-ray detectors. A same CsPbBr3 single crystal was repeatedly deposited with different metal contacts for the evaluation of gamma spectral performance to eliminate crystal-to-crystal variation. Leakage current as low as 2 -3 nA at -200 V with detector thickness 2 -3 mm was consistently achieved with Zr, Bi, Ti, and Ga as Schottky contact metal, which is comparable to the leakage current level of a commercial CZT detector. Gamma energy spectra with a prominent photopeak at 662 keV were consistently acquired with all studied metal contacts. The best resolution at 662 keV is 11% with a peak-to-Compton valley ratio of 2, indicating an improved spectrum shape than previous results. Through 241Am alpha spectra acquisition, the hole mobility of the CsPbBr3 single crystal is evaluated to be 1.78 cm2 V-1 s-1. We also discussed issues related with the CsPbBr3 gamma detector architecture and interface layers, commonly encountered during CsPbBr3 gamma detector fabrication, i.e., impact of electron/hole transport layer and surface oxide layer on gamma detector spectral performance, comparison of different Metal-Perovskite-Metal structures. The persistent CsPbBr3 gamma spectral performance marks the good reproducibility of CsPbBr3 gamma detectors, further enabling CsPbBr3 detector field applications.Keywords
Funding Information
- Department of the Defense, Defense Threat Reduction Agency (HDTRA1-17-1-0054)
This publication has 35 references indexed in Scilit:
- Intrinsic Thermal Instability of Methylammonium Lead Trihalide PerovskiteAdvanced Energy Materials, 2015
- Electron-hole diffusion lengths > 175 μm in solution-grown CH 3 NH 3 PbI 3 single crystalsScience, 2015
- CZT detector technology for medical imagingJournal of Instrumentation, 2014
- Crystal Growth of the Perovskite Semiconductor CsPbBr3: A New Material for High-Energy Radiation DetectionCrystal Growth & Design, 2013
- Study of thick CZT detectors for X-ray and Gamma-ray astronomyAstroparticle Physics, 2011
- SRIM – The stopping and range of ions in matter (2010)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Super high voltage Schottky diode with low leakage current for x- and γ-ray detector applicationApplied Physics Letters, 2009
- Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Signals induced in semiconductor gamma-ray imaging detectorsJournal of Applied Physics, 1999
- Extraction of Schottky diode parameters from forward current-voltage characteristicsApplied Physics Letters, 1986