Lei Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lei Pan has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Mercouri G. Kanatzidis
Northwestern University
8 shared publications Indra Raj Pandey
Department of Chemistry, Northwestern University, Evanston, IL, USA
5 shared publicationsDuck Young Chung
Materials Science Division Argonne National Laboratory Lemont IL 60439 USA
4 shared publications- Jinsong Huang
University of North Carolina at Chapel Hill
4 shared publications - Lei Raymond Cao
The Ohio State University
4 shared publications - Michael C. De Siena
Department of Chemistry Northwestern University Evanston IL 60208 USA
4 shared publications
Latest Publications
- 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 566-573
Geant4 Simulation of Cherenkov Photons in Perovskite CsPbBr 3 Gamma-Ray Detectors
Perovskite materials have recently attracted significant attention for hard X-ray and gamma-ray detection. Cherenkov light generated by fast electrons due to gamma-ray interaction with the material can be used to provide fast timing information. Here, we report Geant4 simulation results of Cherenkov photon generation, transport, and detection within perovskite CsPbBr3. The Cherenkov photon yield, energy spectrum and temporal distribution are investigated under different gamma-ray energy deposition within CsPbBr3. CsPbBr3 has a similar Cherenkov photon yield as of TlBr that has demonstrated fast-timing capability based on Cherenkov light. The effect of crystal volume, surface finish and SiPM photon detection efficiency on the Cherenkov detection is also discussed. This work provides insights into Cherenkov processes of CsPbBr3.
- 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 566-573
Geant4 Simulation of Cherenkov Photons in Perovskite CsPbBr 3 Gamma-Ray Detectors
Perovskite materials have recently attracted significant attention for hard X-ray and gamma-ray detection. Cherenkov light generated by fast electrons due to gamma-ray interaction with the material can be used to provide fast timing information. Here, we report Geant4 simulation results of Cherenkov photon generation, transport, and detection within perovskite CsPbBr3. The Cherenkov photon yield, energy spectrum and temporal distribution are investigated under different gamma-ray energy deposition within CsPbBr3. CsPbBr3 has a similar Cherenkov photon yield as of TlBr that has demonstrated fast-timing capability based on Cherenkov light. The effect of crystal volume, surface finish and SiPM photon detection efficiency on the Cherenkov detection is also discussed. This work provides insights into Cherenkov processes of CsPbBr3.
- 16 October 2025
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 25 (21) , 9288-9299
Progress in Solution Growth of Cuboid CsPbBr 3 Single Crystals with Low Defect Densities and High-Sensitivity X-ray Detection
- 16 October 2025
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 25 (21) , 9288-9299
Progress in Solution Growth of Cuboid CsPbBr 3 Single Crystals with Low Defect Densities and High-Sensitivity X-ray Detection
- 25 November 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (6)
Ion Migration Enhances the Performance of Perovskite CsPbBr 3 γ‐Ray Detectors
Uncontrolled ion migration is well‐known in perovskite‐based semiconductor devices. Here, it is shown that instead of being detrimental, ion migration can be used to enhance the performance of perovskite CsPbBr 3 semiconductor gamma‐ray detectors. Through the deliberate application of electrical biasing, ion migration is actively controlled to modify the metal‐CsPbBr 3 interface barrier height in devices with asymmetric electrodes. Ion migration plays a pivotal role in reducing bulk defects, as evidenced by the contact potential difference measurement, thermally stimulated current spectroscopy and photoluminescence measurements. The evidence suggests that biasing‐induced ion migration in CsPbBr 3 results in a reduction in electron traps and significant detector improvement. As biasing at elevated temperatures expedites ion migration, preconditioning the CsPbBr 3 crystals through reverse biasing is a promising strategy for enhancing their energy‐resolving performance.
- 25 November 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (6)
Ion Migration Enhances the Performance of Perovskite CsPbBr 3 γ‐Ray Detectors
Uncontrolled ion migration is well‐known in perovskite‐based semiconductor devices. Here, it is shown that instead of being detrimental, ion migration can be used to enhance the performance of perovskite CsPbBr 3 semiconductor gamma‐ray detectors. Through the deliberate application of electrical biasing, ion migration is actively controlled to modify the metal‐CsPbBr 3 interface barrier height in devices with asymmetric electrodes. Ion migration plays a pivotal role in reducing bulk defects, as evidenced by the contact potential difference measurement, thermally stimulated current spectroscopy and photoluminescence measurements. The evidence suggests that biasing‐induced ion migration in CsPbBr 3 results in a reduction in electron traps and significant detector improvement. As biasing at elevated temperatures expedites ion migration, preconditioning the CsPbBr 3 crystals through reverse biasing is a promising strategy for enhancing their energy‐resolving performance.
- Open Access
- 26 December 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (24)
Defects of perovskite semiconductor CsPbBr3 investigated via photoluminescence and thermally stimulated current spectroscopies
Halide perovskites are essential materials for hard radiation detectors at ambient temperature. To improve detector performance, charge transport must be investigated and optimized. Using photoluminescence (PL) and thermally stimulated current (TSC) spectroscopies, we investigate photogenerated charge carriers in Bridgman-grown CsPbBr3 single crystals to understand the nature of charge transport. PL spectroscopy of these halide perovskites revealed the presence of strong emission bands at the band edge, which were attributed to free or bound excitons. It is shown that a wide broadening of the excitonic linewidth in these halide perovskites arises from strong exciton–phonon coupling, which is substantially dominated by longitudinal optical phonons via Fröhlich interaction. An additional contribution due to the presence of ionized impurities was also observed. Crystals with a detectable sensitivity to high-energy gamma radiation are characterized by a higher intensity and a narrower linewidth of the principal PL peak at 2.326 eV. Defect states beyond 2.214 eV have a negative impact on detector sensitivity to high-energy gamma radiation. TSC spectroscopy reveals an array of trap levels spanning 0.15–0.70 eV, attributed to intrinsic point defects and multiple extrinsic defects involving dopants or impurities. Defects identified included Cs and Br vacancies, as well as Pb interstitials with concentrations in the 1011–1016 cm−3 range. Understanding how the synthesis process impacts the types and concentrations of the defects present is currently under investigation. Elimination or suppression of the defect/trap states should result in halide perovskite materials with longer carrier diffusion lengths and improved detector characteristics.
- 26 December 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (24)
Open AccessDefects of perovskite semiconductor CsPbBr3 investigated via photoluminescence and thermally stimulated current spectroscopies
Halide perovskites are essential materials for hard radiation detectors at ambient temperature. To improve detector performance, charge transport must be investigated and optimized. Using photoluminescence (PL) and thermally stimulated current (TSC) spectroscopies, we investigate photogenerated charge carriers in Bridgman-grown CsPbBr3 single crystals to understand the nature of charge transport. PL spectroscopy of these halide perovskites revealed the presence of strong emission bands at the band edge, which were attributed to free or bound excitons. It is shown that a wide broadening of the excitonic linewidth in these halide perovskites arises from strong exciton–phonon coupling, which is substantially dominated by longitudinal optical phonons via Fröhlich interaction. An additional contribution due to the presence of ionized impurities was also observed. Crystals with a detectable sensitivity to high-energy gamma radiation are characterized by a higher intensity and a narrower linewidth of the principal PL peak at 2.326 eV. Defect states beyond 2.214 eV have a negative impact on detector sensitivity to high-energy gamma radiation. TSC spectroscopy reveals an array of trap levels spanning 0.15–0.70 eV, attributed to intrinsic point defects and multiple extrinsic defects involving dopants or impurities. Defects identified included Cs and Br vacancies, as well as Pb interstitials with concentrations in the 1011–1016 cm−3 range. Understanding how the synthesis process impacts the types and concentrations of the defects present is currently under investigation. Elimination or suppression of the defect/trap states should result in halide perovskite materials with longer carrier diffusion lengths and improved detector characteristics.
- 25 July 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (38) , e2303244
Extreme γ‐Ray Radiation Tolerance of Spectrometer‐Grade CsPbBr3 Perovskite Detectors
The perovskite compound CsPbBr3 has recently been discovered as a promising room‐temperature semiconductor radiation detector, offering an inexpensive and easy‐to‐manufacture alternative to the current benchmark material Cd1−xZnxTe (CZT). The performance of CsPbBr3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co‐60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. These results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma‐ray radiation.
- 25 July 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (38) , e2303244
Extreme γ‐Ray Radiation Tolerance of Spectrometer‐Grade CsPbBr3 Perovskite Detectors
The perovskite compound CsPbBr3 has recently been discovered as a promising room‐temperature semiconductor radiation detector, offering an inexpensive and easy‐to‐manufacture alternative to the current benchmark material Cd1−xZnxTe (CZT). The performance of CsPbBr3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co‐60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. These results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma‐ray radiation.
- Open Access
- 4 July 2023
- Published by Wiley in Advanced Optical Materials
- Vol. 11 (23)
Quantum Efficiency Gain in 2D Perovskite Photo and X‐Ray Detectors
The perovskite polycrystalline thin film detector fabricated by solution method is a promising low‐cost, scalable technology for radiation imaging, but its thin volume limits the sensing efficiency for high‐energy X‐ray photons. This work reports 2D perovskite thin film photo‐diodes with a detection gain when sensing visible and X‐ray photons. Detailed power and temperature‐dependent device characterizations reveal a charge multiplication effect to be responsible for the observed high gain. This is caused by a disparity in electron and hole transport, where electron transport is retarded by a trap/de‐trap process via shallow trap states, whereas the hole transport is fast enough to produce a photoconductive gain in satisfying the charge neutrality. The 2D perovskite made with butylamine spacers is also found to exhibit a larger efficiency gain than those made with phenylethylamines because of the higher likelihood of forming shallow traps in the former. The thin film diodes feature a high temporal response over 1 MHz due to the fast charge collection across a thin volume, and the discovery provides device physics mechanisms in connection to material structure‐function relationship for future optoelectronics design that can boost the efficiency of X‐ray sensing and dim light detection.
- 4 July 2023
- Published by Wiley in Advanced Optical Materials
- Vol. 11 (23)
Open AccessQuantum Efficiency Gain in 2D Perovskite Photo and X‐Ray Detectors
The perovskite polycrystalline thin film detector fabricated by solution method is a promising low‐cost, scalable technology for radiation imaging, but its thin volume limits the sensing efficiency for high‐energy X‐ray photons. This work reports 2D perovskite thin film photo‐diodes with a detection gain when sensing visible and X‐ray photons. Detailed power and temperature‐dependent device characterizations reveal a charge multiplication effect to be responsible for the observed high gain. This is caused by a disparity in electron and hole transport, where electron transport is retarded by a trap/de‐trap process via shallow trap states, whereas the hole transport is fast enough to produce a photoconductive gain in satisfying the charge neutrality. The 2D perovskite made with butylamine spacers is also found to exhibit a larger efficiency gain than those made with phenylethylamines because of the higher likelihood of forming shallow traps in the former. The thin film diodes feature a high temporal response over 1 MHz due to the fast charge collection across a thin volume, and the discovery provides device physics mechanisms in connection to material structure‐function relationship for future optoelectronics design that can boost the efficiency of X‐ray sensing and dim light detection.
- Open Access
- 15 May 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (19)
Study of perovskite CsPbBr3 detector polarization and its mitigation with ultrahigh x-ray flux
High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, we studied the polarization of perovskite CsPbBr3 semiconductor detectors using ultrahigh flux synchrotron x rays (106–1012 photons s−1 mm−2 at 58.61 keV). The CsPbBr3 detectors did not show immediate polarization prominently until a flux higher than 1010 photons s−1 mm−2. Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr3. We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.
- 15 May 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (19)
Open AccessStudy of perovskite CsPbBr3 detector polarization and its mitigation with ultrahigh x-ray flux
High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, we studied the polarization of perovskite CsPbBr3 semiconductor detectors using ultrahigh flux synchrotron x rays (106–1012 photons s−1 mm−2 at 58.61 keV). The CsPbBr3 detectors did not show immediate polarization prominently until a flux higher than 1010 photons s−1 mm−2. Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr3. We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.
- 29 April 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (25) , 2211840
Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr3 Single‐Crystal Semiconductor Detector
Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 1010 photons s−1 mm−2 is reported. High‐quality solution‐grown CsPbBr3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr3/Au. A high reverse‐bias voltage of 1000 V (435 V mm−1) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm−2), which enables a high sensitivity larger than 10 000 µC Gyair−1 cm−2 and a simultaneous low detection limit of 22 nGyair s−1. The CsPbBr3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 106 to 1010 photons s−1 mm−2. Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr3.
- 29 April 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (25) , 2211840
Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr3 Single‐Crystal Semiconductor Detector
Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 1010 photons s−1 mm−2 is reported. High‐quality solution‐grown CsPbBr3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr3/Au. A high reverse‐bias voltage of 1000 V (435 V mm−1) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm−2), which enables a high sensitivity larger than 10 000 µC Gyair−1 cm−2 and a simultaneous low detection limit of 22 nGyair s−1. The CsPbBr3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 106 to 1010 photons s−1 mm−2. Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr3.
- Open Access
- 27 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (13)
Investigation of defects in melt and solution grown perovskite CsPbBr3 single crystals
Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 1011 to 1 × 1016 cm−3. Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 1014 cm−3. The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. For an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 1011 cm−3.
- 27 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (13)
Open AccessInvestigation of defects in melt and solution grown perovskite CsPbBr3 single crystals
Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 1011 to 1 × 1016 cm−3. Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 1014 cm−3. The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. For an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 1011 cm−3.
- 29 January 2023
- Published by Wiley in Advanced Optical Materials
- Vol. 11 (7)
Perovskite CsPbBr3 Single‐Crystal Detector Operating at 1010 Photons s−1 mm−2 for Ultra‐High Flux X‐ray Detection
Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr3 single‐crystal detector capable of operating at X‐ray fluxes of up to 1010 photons s−1 mm−2 with beam area ≤ 0.25 mm2 at 58.61 keV for current‐mode X‐ray detection is reported. The spectrometer‐grade melt‐grown CsPbBr3 detectors show a gamma‐ray energy resolution of ~7.5% at 122 keV for 57Co and dark current as low as 4.3 nA (0.5 nA mm−2) at a reverse bias voltage of 200 V (118 V mm−1). The detector is tested at X‐ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm−1). Under a sufficiently high bias voltage and within several hundreds of seconds X‐ray exposure, good photocurrent linearity (goodness of fit R2 > 0.99) and reproducibility are obtained up to a flux of ≈1010 photons s−1 mm−2 at beam area 0.25 mm2 with Lower Limit of Detection of ≈105 photons s−1 mm−2 and Charge Collection Efficiency of ≈100% for 58.61 keV X‐rays. Accordingly, wide application of CsPbBr3 detectors in high‐flux X‐ray detection is anticipated.
- 29 January 2023
- Published by Wiley in Advanced Optical Materials
- Vol. 11 (7)
Perovskite CsPbBr3 Single‐Crystal Detector Operating at 1010 Photons s−1 mm−2 for Ultra‐High Flux X‐ray Detection
Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr3 single‐crystal detector capable of operating at X‐ray fluxes of up to 1010 photons s−1 mm−2 with beam area ≤ 0.25 mm2 at 58.61 keV for current‐mode X‐ray detection is reported. The spectrometer‐grade melt‐grown CsPbBr3 detectors show a gamma‐ray energy resolution of ~7.5% at 122 keV for 57Co and dark current as low as 4.3 nA (0.5 nA mm−2) at a reverse bias voltage of 200 V (118 V mm−1). The detector is tested at X‐ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm−1). Under a sufficiently high bias voltage and within several hundreds of seconds X‐ray exposure, good photocurrent linearity (goodness of fit R2 > 0.99) and reproducibility are obtained up to a flux of ≈1010 photons s−1 mm−2 at beam area 0.25 mm2 with Lower Limit of Detection of ≈105 photons s−1 mm−2 and Charge Collection Efficiency of ≈100% for 58.61 keV X‐rays. Accordingly, wide application of CsPbBr3 detectors in high‐flux X‐ray detection is anticipated.