Abstract
This paper theoretically clarifies the difference in magnetic-circuit configurations and reluctance-torque utility of permanent-magnet (PM) motors for the following winding types: (a) distributed winding, (b) 2-pole-and-3-slot-system (2P/3S-system) concentrated winding, and (c) 8-pole-and-9-slot-system (8P/9S-system) FSCW. It was found that the flux of the 8P/9S FSCW intensively pass through the specific poles, which leads to less total magnetic resistance per machine and hence larger reluctance torque than the distributed winding or the 2P/3S-system concentrated winding. It was also shown that the d- axis flux of 2P/3S-system concentrated winding passes through the stator teeth which has less magnetic resistance than the magnets, leading to larger d- axis inductance and hence less reluctance torque than the distributed winding. The established theoretical formulae for calculating reluctance-torque utility were applied to a 2.2-kW concentrated-winding ferrite-magnet motor, and maximum torque of the distributed-winding and FSCW motors was thereby quantified with high accuracy without the need for finite element analysis (FEA). The proposed approach was validated by FEA and experiments.

This publication has 20 references indexed in Scilit: