Akeshi Takahashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akeshi Takahashi has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Wataru Hatsuse
Hitachi, Ltd., Research & Development Group, Hitachi-Shi, Japan
4 shared publications - Mieko Kashiwagi
National Institutes for Quantum and Radiological Science and Technology (QST)
3 shared publications - Satoshi Ichimura
Research & Development Group, Hitachi, Ltd., Hitachi-shi, Japan
3 shared publications - Tetsuya Suto
Hitachi, Ltd
3 shared publications Hiroyuki Fujita
Power Systems Business Unit, Hitachi, Ltd., Hitachi-shi, Japan
2 shared publications- Hiroyuki Tobari
National Institutes for Quantum Science and Technology (QST), Naka, Ibaraki, Japan
2 shared publications
Latest Publications
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 726-736
Induction Motor Drive System With Novel Mechanical Winding Changeover Device
This report presents a mechanical winding- changeover system to improve energy consumption of traction motors for automobiles. Conventional mechanical winding changeover devices have two drawbacks: large volume for large current, and short lifetime due to contact arc. We have adopted multi contacts to downsize the winding changeover device, which results in half size compared with the conventional relay structure of 5 L, with rated current of 440 Arms. We also established the operation principle which does not occur any contact arc, where the switching timing is controlled so that the motor internal voltage is constantly below the inverter DC voltage. Our developed winding changeover device can be provided with the longer lifetime of the switching contact. The actual test of 1.5 kW induction motor (IM) system demonstrated that the contact arc did not occur at the winding changeover operation during motor acceleration. Measurement results also demonstrated that the proposed winding changeover devices would endure the switching more than 200,000 reciprocation. Furthermore, energy loss was estimated to be reduced by 4% at WLTC mode because of the improvement of system efficiency due to winding changeover.
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 726-736
Induction Motor Drive System With Novel Mechanical Winding Changeover Device
This report presents a mechanical winding- changeover system to improve energy consumption of traction motors for automobiles. Conventional mechanical winding changeover devices have two drawbacks: large volume for large current, and short lifetime due to contact arc. We have adopted multi contacts to downsize the winding changeover device, which results in half size compared with the conventional relay structure of 5 L, with rated current of 440 Arms. We also established the operation principle which does not occur any contact arc, where the switching timing is controlled so that the motor internal voltage is constantly below the inverter DC voltage. Our developed winding changeover device can be provided with the longer lifetime of the switching contact. The actual test of 1.5 kW induction motor (IM) system demonstrated that the contact arc did not occur at the winding changeover operation during motor acceleration. Measurement results also demonstrated that the proposed winding changeover devices would endure the switching more than 200,000 reciprocation. Furthermore, energy loss was estimated to be reduced by 4% at WLTC mode because of the improvement of system efficiency due to winding changeover.
- 29 August 2023
- Published by Springer Nature
- p. 1-11
Direct Drive System to Make In-Wheel Electric Vehicles Closer to a Production Reality
- 29 August 2023
- Published by Springer Nature
- p. 1-11
Direct Drive System to Make In-Wheel Electric Vehicles Closer to a Production Reality
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5932-5944
Difference in Reluctance-Torque Utility for Different Motor Winding Types
This paper theoretically clarifies the difference in magnetic-circuit configurations and reluctance-torque utility of permanent-magnet (PM) motors for the following winding types: (a) distributed winding, (b) 2-pole-and-3-slot-system (2P/3S-system) concentrated winding, and (c) 8-pole-and-9-slot-system (8P/9S-system) FSCW. It was found that the flux of the 8P/9S FSCW intensively pass through the specific poles, which leads to less total magnetic resistance per machine and hence larger reluctance torque than the distributed winding or the 2P/3S-system concentrated winding. It was also shown that the d- axis flux of 2P/3S-system concentrated winding passes through the stator teeth which has less magnetic resistance than the magnets, leading to larger d- axis inductance and hence less reluctance torque than the distributed winding. The established theoretical formulae for calculating reluctance-torque utility were applied to a 2.2-kW concentrated-winding ferrite-magnet motor, and maximum torque of the distributed-winding and FSCW motors was thereby quantified with high accuracy without the need for finite element analysis (FEA). The proposed approach was validated by FEA and experiments.
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5932-5944
Difference in Reluctance-Torque Utility for Different Motor Winding Types
This paper theoretically clarifies the difference in magnetic-circuit configurations and reluctance-torque utility of permanent-magnet (PM) motors for the following winding types: (a) distributed winding, (b) 2-pole-and-3-slot-system (2P/3S-system) concentrated winding, and (c) 8-pole-and-9-slot-system (8P/9S-system) FSCW. It was found that the flux of the 8P/9S FSCW intensively pass through the specific poles, which leads to less total magnetic resistance per machine and hence larger reluctance torque than the distributed winding or the 2P/3S-system concentrated winding. It was also shown that the d- axis flux of 2P/3S-system concentrated winding passes through the stator teeth which has less magnetic resistance than the magnets, leading to larger d- axis inductance and hence less reluctance torque than the distributed winding. The established theoretical formulae for calculating reluctance-torque utility were applied to a 2.2-kW concentrated-winding ferrite-magnet motor, and maximum torque of the distributed-winding and FSCW motors was thereby quantified with high accuracy without the need for finite element analysis (FEA). The proposed approach was validated by FEA and experiments.
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4398-4408
1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System
This article presents the development results of a five-stage dc-1 MV rectifier for an international thermonuclear experimental reactor neutral beam injector system. Each rectifier outputs -200 kV, and the total five rectifiers are connected in a series. The feasibility of both gas insulation and gas cooling for semiconductor devices was validated to achieve dc-1 MV output and 1-h continuous operation. We devised a novel structure of cylindrical dense alignment of the heatsinks with stud-type diodes, which enables both the mitigation of electric-field concentration on the heatsinks and the improvement of heat dissipation from diodes. The difference in the temperature rise for three different directions of the heatsink in an SF 6 gas atmosphere was also clarified. The heat flow was analyzed to quantify the cooling effect of SF 6 gas, taking into account the gas circulation by the external cooling system. Rectification operation and temperature rise were tested with an actual-scale rectifier including a step-up transformer. Additionally, dc-1.2 MV withstand voltage was tested for a fifth-stage actual-scale rectifier. The test results demonstrated the validity of the proposed design.
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4398-4408
1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System
This article presents the development results of a five-stage dc-1 MV rectifier for an international thermonuclear experimental reactor neutral beam injector system. Each rectifier outputs -200 kV, and the total five rectifiers are connected in a series. The feasibility of both gas insulation and gas cooling for semiconductor devices was validated to achieve dc-1 MV output and 1-h continuous operation. We devised a novel structure of cylindrical dense alignment of the heatsinks with stud-type diodes, which enables both the mitigation of electric-field concentration on the heatsinks and the improvement of heat dissipation from diodes. The difference in the temperature rise for three different directions of the heatsink in an SF 6 gas atmosphere was also clarified. The heat flow was analyzed to quantify the cooling effect of SF 6 gas, taking into account the gas circulation by the external cooling system. Rectification operation and temperature rise were tested with an actual-scale rectifier including a step-up transformer. Additionally, dc-1.2 MV withstand voltage was tested for a fifth-stage actual-scale rectifier. The test results demonstrated the validity of the proposed design.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2803-2813
Difference in Base Frequency and Torque Between Distributed and Concentrated Windings in Permanent Magnet Motors
This paper formulates the difference in base frequency and maximum torque between distributed and concentrated windings taking into account the air-gap modulation of concentrated-winding permanent magnet (PM) motors. The design superiority is typically confirmed for each winding type during a development period by using time-consuming finite element analysis (FEA). We propose a quantification that enables motor designers to easily judge, at the initial design stage, a superior winding type and to shorten a design period. Throughout our formulation, we found that the distributed-winding PM motors, in principle, have larger q-axis inductance and smaller d-axis inductance than the concentrated-winding motors, which leads to a decrease in the base frequency. On the other hand, the distributed winding inherently has higher winding factor and needs shorter stack length of core than the concentrated winding for identical torque output, which results in an increase in the base frequency. And also, we theoretically quantified the difference in reluctance-torque contribution between the two winding types and found that it was too small to have much impact on practical design. We applied the proposed formulae to a 0.2-kW concentrated-winding motor.The FEA and measurement results demonstrated the validity of the proposed approach for the fabricated distributed-winding motor.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2803-2813
Difference in Base Frequency and Torque Between Distributed and Concentrated Windings in Permanent Magnet Motors
This paper formulates the difference in base frequency and maximum torque between distributed and concentrated windings taking into account the air-gap modulation of concentrated-winding permanent magnet (PM) motors. The design superiority is typically confirmed for each winding type during a development period by using time-consuming finite element analysis (FEA). We propose a quantification that enables motor designers to easily judge, at the initial design stage, a superior winding type and to shorten a design period. Throughout our formulation, we found that the distributed-winding PM motors, in principle, have larger q-axis inductance and smaller d-axis inductance than the concentrated-winding motors, which leads to a decrease in the base frequency. On the other hand, the distributed winding inherently has higher winding factor and needs shorter stack length of core than the concentrated winding for identical torque output, which results in an increase in the base frequency. And also, we theoretically quantified the difference in reluctance-torque contribution between the two winding types and found that it was too small to have much impact on practical design. We applied the proposed formulae to a 0.2-kW concentrated-winding motor.The FEA and measurement results demonstrated the validity of the proposed approach for the fabricated distributed-winding motor.
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 7587-7599
–1 MV DC Filter and High-Voltage DC Measurement System for ITER Neutral Beam Injector System
This report proposes the one-package structure of -1 MV direct current (DC) filter circuit and DC measurement system composed of DC voltage dividers and DC current transducers (DCCTs). These apparatuses are becoming more important for the expansion of high-voltage DC (HVDC) power grids. However, at present, they are separately installed keeping a huge distance for air insulation, and an increase in equipment size and footprint has become a major issue. We succeeded in reducing the footprint to 1/100 by storing the aforementioned HVDC vital parts in one package of a pressure vessel. Our developed configuration uses sulfur hexafluoride (SF6) gas not only for insulation purpose but also as a refrigerant to forcibly ventilate vertically in order to allow the DC filter circuit, which is heat generation source, and the DC measuring instruments, which need to minimize the effect of temperature drift, to coexist. We also addressed another issue caused by the limited space in the one-package structure, where the stray capacitance of the DC voltage divider tends to become large and then lowers the measurement accuracy for transient voltage variation. As a countermeasure, the DC voltage divider is composed larger capacitance and additional damping resistance to avoid LC resonance. The actual-product tests demonstrated the followings; the DC measurement system has satisfied high measurement accuracy of 0.5% and fast responsivity of 3.3 $\mu$ s retaining decay rate within -3 dB; the temperature rise of the DC voltage dividers and the DCCTs is reasonably suppressed; the DC measurement system and the DC filter circuit withstood DC -1.2 MV.- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 7587-7599
–1 MV DC Filter and High-Voltage DC Measurement System for ITER Neutral Beam Injector System
This report proposes the one-package structure of -1 MV direct current (DC) filter circuit and DC measurement system composed of DC voltage dividers and DC current transducers (DCCTs). These apparatuses are becoming more important for the expansion of high-voltage DC (HVDC) power grids. However, at present, they are separately installed keeping a huge distance for air insulation, and an increase in equipment size and footprint has become a major issue. We succeeded in reducing the footprint to 1/100 by storing the aforementioned HVDC vital parts in one package of a pressure vessel. Our developed configuration uses sulfur hexafluoride (SF6) gas not only for insulation purpose but also as a refrigerant to forcibly ventilate vertically in order to allow the DC filter circuit, which is heat generation source, and the DC measuring instruments, which need to minimize the effect of temperature drift, to coexist. We also addressed another issue caused by the limited space in the one-package structure, where the stray capacitance of the DC voltage divider tends to become large and then lowers the measurement accuracy for transient voltage variation. As a countermeasure, the DC voltage divider is composed larger capacitance and additional damping resistance to avoid LC resonance. The actual-product tests demonstrated the followings; the DC measurement system has satisfied high measurement accuracy of 0.5% and fast responsivity of 3.3 $\mu$ s retaining decay rate within -3 dB; the temperature rise of the DC voltage dividers and the DCCTs is reasonably suppressed; the DC measurement system and the DC filter circuit withstood DC -1.2 MV.- Open Access
- 12 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 34 (4) , 1751-1758
Novel Criterion for Reluctance Torque Utility of Permanent Magnet Motors
A novel criterion for the utility of reluctance torque in permanent magnet (PM) motors is developed. The criterion, reluctance torque ratio α, can be quantified by using the PM flux linkage $\psy_p$ of the stator phase windings, the current I, and the direct- and quadrature-axis inductances Ld and Lq, respectively. It has been shown that the conventional salient-pole ratio is not helpful in clearly judging the utility, while the ratio α can be used to make such judgements across various types of motors with different applications and outputs. Through both theoretical consideration and experiments it has been proved that a motor with large PM flux linkage utilizes little reluctance torque even if the salient-pole ratio Lq/Ld is over 2.0 and that a large Lq/Ld increases iron loss, thus decreasing motor efficiency. We have also shown that the above loss increase is caused by the significant superposition of q-axis flux due to the large Lq and have concluded that, in the above case, selecting a rotor geometry with less saliency can improve efficiency. Results are given for two types of four-pole prototype motors with an output power of 0.6 kW, a rated rotation number of 3600 min $^{-1}$ , and Y-connection.- 12 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 34 (4) , 1751-1758
Open AccessNovel Criterion for Reluctance Torque Utility of Permanent Magnet Motors
A novel criterion for the utility of reluctance torque in permanent magnet (PM) motors is developed. The criterion, reluctance torque ratio α, can be quantified by using the PM flux linkage $\psy_p$ of the stator phase windings, the current I, and the direct- and quadrature-axis inductances Ld and Lq, respectively. It has been shown that the conventional salient-pole ratio is not helpful in clearly judging the utility, while the ratio α can be used to make such judgements across various types of motors with different applications and outputs. Through both theoretical consideration and experiments it has been proved that a motor with large PM flux linkage utilizes little reluctance torque even if the salient-pole ratio Lq/Ld is over 2.0 and that a large Lq/Ld increases iron loss, thus decreasing motor efficiency. We have also shown that the above loss increase is caused by the significant superposition of q-axis flux due to the large Lq and have concluded that, in the above case, selecting a rotor geometry with less saliency can improve efficiency. Results are given for two types of four-pole prototype motors with an output power of 0.6 kW, a rated rotation number of 3600 min $^{-1}$ , and Y-connection. - 12 March 2018
- Published by Wiley in Electrical Engineering in Japan
- Vol. 204 (1) , 3-11
Development of DC-1 MV Ultrahigh Voltage Generator for ITER
- 12 March 2018
- Published by Wiley in Electrical Engineering in Japan
- Vol. 204 (1) , 3-11
Development of DC-1 MV Ultrahigh Voltage Generator for ITER
- Open Access
- 1 January 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (2) , 166-174
Development of -1MV DC Filter and High-voltage DC Measurement Systems for ITER NBI
This paper presents the development results of a -1MV DC filter and DC measurement systems for an ITER neutral beam injector system. High accuracy of 0.5% and fast responsivity of 3.3µs, -3dB are required for the DC measurement systems: both DC voltage dividers and DCCTs. Circuit design and thermal flow design were carried out to clarify and minimize their effects on the accuracy and responsivity. The validity of the established design was demonstrated by the actual-product tests; temperature rise of each components fell below the allowable value; inner components of DC filter withstood DC -1.2MV; each voltage divider accurately measured the voltage during the DC -1.2MV withstand voltage test; the voltage dividers and the DCCTs were adequate to the requirements of responsivity (3.3µs, -3dB).
- 1 January 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (2) , 166-174
Open AccessDevelopment of -1MV DC Filter and High-voltage DC Measurement Systems for ITER NBI
This paper presents the development results of a -1MV DC filter and DC measurement systems for an ITER neutral beam injector system. High accuracy of 0.5% and fast responsivity of 3.3µs, -3dB are required for the DC measurement systems: both DC voltage dividers and DCCTs. Circuit design and thermal flow design were carried out to clarify and minimize their effects on the accuracy and responsivity. The validity of the established design was demonstrated by the actual-product tests; temperature rise of each components fell below the allowable value; inner components of DC filter withstood DC -1.2MV; each voltage divider accurately measured the voltage during the DC -1.2MV withstand voltage test; the voltage dividers and the DCCTs were adequate to the requirements of responsivity (3.3µs, -3dB).
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Industry Applications
- Vol. 134 (5) , 479-485
Iron Loss Analysis of Permanent Magnet Motors Fed by PWM Inverter
Carrier harmonic losses that consist of iron loss, eddy current loss, and ac copper loss are generated in a permanent magnet machine driven by a PWM inverter. It is already known that a higher motor inductance can lead to lower carrier harmonic losses. This paper investigated the carrier harmonic loss composition of two motors with identical dimensions but different inductances. The finite element analysis (FEA) results showed that the eddy current loss in the iron core accounts for most part of the carrier harmonic losses. It is also proved that the carrier harmonic loss of the iron core is quantifiable using theoretical calculations.
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Industry Applications
- Vol. 134 (5) , 479-485
Iron Loss Analysis of Permanent Magnet Motors Fed by PWM Inverter
Carrier harmonic losses that consist of iron loss, eddy current loss, and ac copper loss are generated in a permanent magnet machine driven by a PWM inverter. It is already known that a higher motor inductance can lead to lower carrier harmonic losses. This paper investigated the carrier harmonic loss composition of two motors with identical dimensions but different inductances. The finite element analysis (FEA) results showed that the eddy current loss in the iron core accounts for most part of the carrier harmonic losses. It is also proved that the carrier harmonic loss of the iron core is quantifiable using theoretical calculations.