Abstract
Using the amorphous magnetically soft cobalt based AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) alloy as an example, the effect of low-temperature annealing on the magnetic characteristics of a ribbon has been studied. The results of a systematic study of the effects of heat treatment in air at 90–250°C on the magnetization distribution and maximum magnetic permeability have demonstrated that the magnetostriction constant does not change its sign within a range of isothermal exposure times from 1 to 30 min. In this case, the dependence of the maximum magnetic permeability on the heat treatment parameters has a nonmonotonical character caused by the redistribution of magnetization in the ribbon under annealing. The change in the magnetic characteristics is caused by diffusion processes: free volume release, the surface oxidation and hydrogenation of a ribbon in contact with atmospheric vapor, and the crystallization of its free surface.

This publication has 17 references indexed in Scilit: