Nadezhda A. Skulkina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nadezhda A. Skulkina has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
O. A. Ivanov
Ural Federal University
15 shared publicationsE. S. Nekrasov
Ural Federal University
9 shared publicationsI. O. Pavlova
Yeltsin Ural Federal University
8 shared publicationsA. K. Mazeeva
Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russia
7 shared publicationsN. D. Denisov
Ural Federal University named after the first President of Russia B.N. Yeltsin, Ekaterinburg, Russia
7 shared publicationsE. A. Stepanova
6 shared publications
Latest Publications
- 1 October 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (5) , 1107-1118
Effect of Low-Temperature Annealing on Magnetic Characteristics and Their Uniformity in Cobalt-Based Amorphous Alloy
The effect of heat treatment in air at 200–250°C on the magnetic properties and their uniformity in ribbon samples of the cobalt-based amorphous soft magnetic alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) was studied. In the quenched state, the nonuniformity of the magnetic properties of the ribbons is related to the manufacturing process, namely, the presence of cooling rate gradients. Heat treatment in air within the studied temperature range, with various durations of isothermal holding, was found not to improve the magnetic properties of the ribbon or enhance their uniformity. The formation of bimodal and trimodal field dependences of magnetic permeability indicates that the ribbon becomes stratified across its thickness during annealing. The decrease in maximum magnetic permeability is attributed to the reorientation of magnetization perpendicular to both the ribbon plane and the ribbon axis within its plane. The results are explained by the influence of anisotropic stresses induced by oxidation, hydrogenation of the ribbon surface, and its surface crystallization.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (5) , 1107-1118
Effect of Low-Temperature Annealing on Magnetic Characteristics and Their Uniformity in Cobalt-Based Amorphous Alloy
The effect of heat treatment in air at 200–250°C on the magnetic properties and their uniformity in ribbon samples of the cobalt-based amorphous soft magnetic alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) was studied. In the quenched state, the nonuniformity of the magnetic properties of the ribbons is related to the manufacturing process, namely, the presence of cooling rate gradients. Heat treatment in air within the studied temperature range, with various durations of isothermal holding, was found not to improve the magnetic properties of the ribbon or enhance their uniformity. The formation of bimodal and trimodal field dependences of magnetic permeability indicates that the ribbon becomes stratified across its thickness during annealing. The decrease in maximum magnetic permeability is attributed to the reorientation of magnetization perpendicular to both the ribbon plane and the ribbon axis within its plane. The results are explained by the influence of anisotropic stresses induced by oxidation, hydrogenation of the ribbon surface, and its surface crystallization.
- 22 September 2024
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 125 (2) , 144-152
Magnetization processes features in the tapes of cobalt-based amorphous alloy
Studies of the amorphous cobalt-based soft magnetic alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) from different manufacturers have shown that in the as-quenched state there is nonuniformity of the magnetic characteristics, and therefore the level of internal stresses across the width of the tape produced by MSTATOR (Borovichi) significantly lower. However, similar to the tape produced by NIIMET (Kaluga), there is nonuniformity of the tape in thickness, which contributes to the formation of a bimodal field dependence of magnetic permeability.This may be a consequence of the non-uniform concentration along the width of the tape of hydrogen and oxygen atoms embedded in its surface during interaction with atmospheric vapor and the presence of temperature gradients during the manufacturing process. A stepwise shape of the initial sections of the magnetization curves in the region of the first maximum of magnetic permeability was discovered. The abrupt nature of the magnetization processes in the region of weak fields allows us to conclude that in the samples of tape produced by MSTATOR, the formation of the first maximum of the field dependence is associated with an independent magnetization reversal of the surface layer, while the main layer of the tape participates in the formation of the second maximum. The smoothed shape of the stepped initial section of the magnetization curve of samples produced by NIIMET corresponds to the gradual involvement of the main layer of the tape in the processes of magnetization and remagnetization. A comparison of the hysteresis loops of both parts of the tape, measured in the same magnetic field region, shows that the field shift of the hysteresis loops is associated with the interlayer interaction of the surface and volume of the tape, and the formation of asymmetric hysteresis loops occurs with the participation of the second layer with its gradual involvement in the processes of magnetization and magnetization reversal.
- 22 September 2024
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 125 (2) , 144-152
Magnetization processes features in the tapes of cobalt-based amorphous alloy
Studies of the amorphous cobalt-based soft magnetic alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) from different manufacturers have shown that in the as-quenched state there is nonuniformity of the magnetic characteristics, and therefore the level of internal stresses across the width of the tape produced by MSTATOR (Borovichi) significantly lower. However, similar to the tape produced by NIIMET (Kaluga), there is nonuniformity of the tape in thickness, which contributes to the formation of a bimodal field dependence of magnetic permeability.This may be a consequence of the non-uniform concentration along the width of the tape of hydrogen and oxygen atoms embedded in its surface during interaction with atmospheric vapor and the presence of temperature gradients during the manufacturing process. A stepwise shape of the initial sections of the magnetization curves in the region of the first maximum of magnetic permeability was discovered. The abrupt nature of the magnetization processes in the region of weak fields allows us to conclude that in the samples of tape produced by MSTATOR, the formation of the first maximum of the field dependence is associated with an independent magnetization reversal of the surface layer, while the main layer of the tape participates in the formation of the second maximum. The smoothed shape of the stepped initial section of the magnetization curve of samples produced by NIIMET corresponds to the gradual involvement of the main layer of the tape in the processes of magnetization and remagnetization. A comparison of the hysteresis loops of both parts of the tape, measured in the same magnetic field region, shows that the field shift of the hysteresis loops is associated with the interlayer interaction of the surface and volume of the tape, and the formation of asymmetric hysteresis loops occurs with the participation of the second layer with its gradual involvement in the processes of magnetization and magnetization reversal.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 125 (2) , 129-136
Peculiarities of Magnetization Processes of Cobalt-Based Amorphous Alloy Ribbons in the As-Quenched State
—Studies of soft magnetic Co-based amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) produced by different manufacturers show that, in the as-quenched state, the nonuniformity of magnetic characteristics across the width of ribbon produced in the PC MSTATOR (Borovichi) is substantially lower. However, the nonuniformity across the ribbon thickness takes place, which favors the formation of bimodal field dependence of the magnetic permeability. The stepped shape of initial portions of magnetization curves in the range of the first maximum of magnetic permeability and intermittent character of the magnetization processes in weak fields allow us to conclude that the formation of the first maximum in the field dependence for the ribbons produced in the PC MSTATOR is related to the independent magnetization reversal of the surface layer. The base layer of the ribbon participates in the formation of the second maximum. In the case of samples manufactured in the JSC NIIMET, the smoothed shape of stepped initial portion of the magnetization curve corresponds to progressive involvement of the base layer of ribbon into the magnetization and magnetization reversal processes. An analysis of hysteresis loops shows that the field bias is related to the interlayer interaction of the surface and the bulk of the ribbon, whereas the formation of asymmetric hysteresis loops occurs with the participation of the second layer with gradual implementation of it into the magnetization and magnetization reversal processes.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 125 (2) , 129-136
Peculiarities of Magnetization Processes of Cobalt-Based Amorphous Alloy Ribbons in the As-Quenched State
—Studies of soft magnetic Co-based amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) produced by different manufacturers show that, in the as-quenched state, the nonuniformity of magnetic characteristics across the width of ribbon produced in the PC MSTATOR (Borovichi) is substantially lower. However, the nonuniformity across the ribbon thickness takes place, which favors the formation of bimodal field dependence of the magnetic permeability. The stepped shape of initial portions of magnetization curves in the range of the first maximum of magnetic permeability and intermittent character of the magnetization processes in weak fields allow us to conclude that the formation of the first maximum in the field dependence for the ribbons produced in the PC MSTATOR is related to the independent magnetization reversal of the surface layer. The base layer of the ribbon participates in the formation of the second maximum. In the case of samples manufactured in the JSC NIIMET, the smoothed shape of stepped initial portion of the magnetization curve corresponds to progressive involvement of the base layer of ribbon into the magnetization and magnetization reversal processes. An analysis of hysteresis loops shows that the field bias is related to the interlayer interaction of the surface and the bulk of the ribbon, whereas the formation of asymmetric hysteresis loops occurs with the participation of the second layer with gradual implementation of it into the magnetization and magnetization reversal processes.
- 1 August 2023
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 124 (8) , 774-780
Nonuniformity of Magnetization Processes of a Co-Based Amorphous Alloy Ribbon in the As-Quenched State
The results of investigation of the nonuniformity of magnetization processes in an as-quenched ribbon of soft magnetic cobalt-based amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) are reported. The studies show that the prime cause for the nonuniformity of magnetic characteristics and magnetization processes is the nonuniformity of internal quenching stresses. The indirect characteristic of such stresses is the volume of domains with an orthogonal magnetization component. In the region of 180° domain wall motion, a bimodal field dependence of magnetic permeability and a bias field of hysteresis loops are found, which result from the ribbon nonuniformity across the thickness. The bias field and asymmetry of hysteresis loops are explained in terms of the formation unidirectional exchange anisotropy at the interface of ferromagnetic and antiferromagnetic phases of planar magnetization components oriented along the ribbon axis. The disappearance of bias field and hysteresis loop asymmetry across the ribbon width can be explained by decreasing the thickness of antiferromagnetic CoO oxide layer because of the different concentrations and depth of penetration of oxygen and hydrogen atoms introduced into the ribbon surface, which result from the interaction with atmosphere vapor in the course of ribbon preparation.
- 1 August 2023
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 124 (8) , 774-780
Nonuniformity of Magnetization Processes of a Co-Based Amorphous Alloy Ribbon in the As-Quenched State
The results of investigation of the nonuniformity of magnetization processes in an as-quenched ribbon of soft magnetic cobalt-based amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) are reported. The studies show that the prime cause for the nonuniformity of magnetic characteristics and magnetization processes is the nonuniformity of internal quenching stresses. The indirect characteristic of such stresses is the volume of domains with an orthogonal magnetization component. In the region of 180° domain wall motion, a bimodal field dependence of magnetic permeability and a bias field of hysteresis loops are found, which result from the ribbon nonuniformity across the thickness. The bias field and asymmetry of hysteresis loops are explained in terms of the formation unidirectional exchange anisotropy at the interface of ferromagnetic and antiferromagnetic phases of planar magnetization components oriented along the ribbon axis. The disappearance of bias field and hysteresis loop asymmetry across the ribbon width can be explained by decreasing the thickness of antiferromagnetic CoO oxide layer because of the different concentrations and depth of penetration of oxygen and hydrogen atoms introduced into the ribbon surface, which result from the interaction with atmosphere vapor in the course of ribbon preparation.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 123 (8) , 753-758
The Effect of Low-Temperature Annealing on the Magnetic Characteristics of an Amorphous Magnetically Soft Cobalt Based Alloy
Using the amorphous magnetically soft cobalt based AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) alloy as an example, the effect of low-temperature annealing on the magnetic characteristics of a ribbon has been studied. The results of a systematic study of the effects of heat treatment in air at 90–250°C on the magnetization distribution and maximum magnetic permeability have demonstrated that the magnetostriction constant does not change its sign within a range of isothermal exposure times from 1 to 30 min. In this case, the dependence of the maximum magnetic permeability on the heat treatment parameters has a nonmonotonical character caused by the redistribution of magnetization in the ribbon under annealing. The change in the magnetic characteristics is caused by diffusion processes: free volume release, the surface oxidation and hydrogenation of a ribbon in contact with atmospheric vapor, and the crystallization of its free surface.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 123 (8) , 753-758
The Effect of Low-Temperature Annealing on the Magnetic Characteristics of an Amorphous Magnetically Soft Cobalt Based Alloy
Using the amorphous magnetically soft cobalt based AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) alloy as an example, the effect of low-temperature annealing on the magnetic characteristics of a ribbon has been studied. The results of a systematic study of the effects of heat treatment in air at 90–250°C on the magnetization distribution and maximum magnetic permeability have demonstrated that the magnetostriction constant does not change its sign within a range of isothermal exposure times from 1 to 30 min. In this case, the dependence of the maximum magnetic permeability on the heat treatment parameters has a nonmonotonical character caused by the redistribution of magnetization in the ribbon under annealing. The change in the magnetic characteristics is caused by diffusion processes: free volume release, the surface oxidation and hydrogenation of a ribbon in contact with atmospheric vapor, and the crystallization of its free surface.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 123 (8) , 733-739
The Effect of Treatment with Acetone on the Change in the Magnetic Characteristics of an Amorphous Cobalt Based Alloy with Time
Studies have demonstrated that the surface treatment of an amorphous magnetically soft Co–Ni–Fe–Cr–Mn–Si–B alloy ribbon with acetone exerts an effect on the change in magnetic characteristics with time. The observed change in the maximum magnetic permeability is associated with changing the magnetization distribution in the ribbon under the influence of stresses induced by diffusion processes at room temperature. These include surface crystallization processes accompanied by the redistribution of hydrogen and oxygen atoms intruded at an increased temperature due to the interaction between the ribbon surface and the atmospheric vapor. The effect of stresses induced by diffusion processes is different for states with various signs of the magnetostriction constant.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 123 (8) , 733-739
The Effect of Treatment with Acetone on the Change in the Magnetic Characteristics of an Amorphous Cobalt Based Alloy with Time
Studies have demonstrated that the surface treatment of an amorphous magnetically soft Co–Ni–Fe–Cr–Mn–Si–B alloy ribbon with acetone exerts an effect on the change in magnetic characteristics with time. The observed change in the maximum magnetic permeability is associated with changing the magnetization distribution in the ribbon under the influence of stresses induced by diffusion processes at room temperature. These include surface crystallization processes accompanied by the redistribution of hydrogen and oxygen atoms intruded at an increased temperature due to the interaction between the ribbon surface and the atmospheric vapor. The effect of stresses induced by diffusion processes is different for states with various signs of the magnetostriction constant.
- 1 November 2021
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 122 (11) , 1060-1065
Interaction of the Ribbon Surface with Acetone and Magnetic Characteristics of the Soft Magnetic Co-Based Amorphous Alloy
The performed studies showed that the treatment of a ribbon of soft magnetic Co–Ni–Fe–Cr–Mn–Si–B amorphous alloy with acetone affects the magnetic characteristics of the ribbon. The effect is different for the states of the ribbon differing in the sign of magnetostriction constant (λs). In the case of the state with λs > 0, both the volume of domains with the orthogonal magnetization component and the sharpness of the in-plane magnetic texture increase; at λs < 0, a decrease in the volume of domains with the orthogonal magnetization, a decrease in the sharpness of the in-plane magnetic texture, and an increase in the maximum magnetic permeability take place. The increase in the time of the treatment magnifies its effect on the volume component of magnetization and decreases the effect on the in-plane magnetization redistribution. This can be related to an increase in the level of compressive stresses induced by catalytic oxidation and hydrogenation of acetone.
- 1 November 2021
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 122 (11) , 1060-1065
Interaction of the Ribbon Surface with Acetone and Magnetic Characteristics of the Soft Magnetic Co-Based Amorphous Alloy
The performed studies showed that the treatment of a ribbon of soft magnetic Co–Ni–Fe–Cr–Mn–Si–B amorphous alloy with acetone affects the magnetic characteristics of the ribbon. The effect is different for the states of the ribbon differing in the sign of magnetostriction constant (λs). In the case of the state with λs > 0, both the volume of domains with the orthogonal magnetization component and the sharpness of the in-plane magnetic texture increase; at λs < 0, a decrease in the volume of domains with the orthogonal magnetization, a decrease in the sharpness of the in-plane magnetic texture, and an increase in the maximum magnetic permeability take place. The increase in the time of the treatment magnifies its effect on the volume component of magnetization and decreases the effect on the in-plane magnetization redistribution. This can be related to an increase in the level of compressive stresses induced by catalytic oxidation and hydrogenation of acetone.
- 1 November 2021
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 122 (11) , 1054-1059
Nonuniformity of Magnetic Characteristics of a Cobalt-Based Amorphous Alloy in the As-Quenched State
To ascertain opportunities for the optimization of magnetic properties of a cobalt-based soft magnetic amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) results of systematic studies of their nonuniformity in the as-quenched state are reported. The studies showed the existence of the substantial nonuniformity of magnetic characteristics both across the ribbon width and along the ribbon length. The nonuniformity of magnetic characteristics along the ribbon length is periodical in character and sinusoidal; this can be related to the manufacturing conditions of the ribbon. Variations of the maximum magnetic permeability and volume of domains with an orthogonal magnetization component are in antiphase. A bimodal field dependence of the magnetic permeability is found, which can result from the nonuniformity of the characteristics across the ribbon thickness.
- 1 November 2021
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 122 (11) , 1054-1059
Nonuniformity of Magnetic Characteristics of a Cobalt-Based Amorphous Alloy in the As-Quenched State
To ascertain opportunities for the optimization of magnetic properties of a cobalt-based soft magnetic amorphous alloy AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) results of systematic studies of their nonuniformity in the as-quenched state are reported. The studies showed the existence of the substantial nonuniformity of magnetic characteristics both across the ribbon width and along the ribbon length. The nonuniformity of magnetic characteristics along the ribbon length is periodical in character and sinusoidal; this can be related to the manufacturing conditions of the ribbon. Variations of the maximum magnetic permeability and volume of domains with an orthogonal magnetization component are in antiphase. A bimodal field dependence of the magnetic permeability is found, which can result from the nonuniformity of the characteristics across the ribbon thickness.
- 1 January 2021
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 122 (11) , 1142-1148
Взаимодействие поверхности ленты с ацетоном и магнитные характеристики аморфного магнитомягкого сплава на основе кобальта
Проведенные исследования показали, что обработка ацетоном ленты аморфного магнитомягкого сплава Co–Ni–Fe–Cr–Mn–Si–B оказывает влияние на ее магнитные характеристики. Оно различно для состояний ленты с разными знаками константы магнитострикции (λs). В состоянии с λs > 0 наблюдается увеличение объема доменов с ортогональной намагниченностью и остроты магнитной текстуры в плоскости ленты; с λs < 0 имеет место уменьшение объема доменов с ортогональной намагниченностью, снижение остроты магнитной текстуры в плоскости ленты и повышение максимальной магнитной проницаемости. Увеличение длительности обработки усиливает ее влияние на объемную компоненту намагниченности и ослабляет воздействие на перераспределение намагниченности в плоскости ленты. Это может быть связано с повышением уровня сжимающих напряжений, индуцированных каталитическим окислением и гидрированием ацетона.
- 1 January 2021
- Published by The Russian Academy of Sciences in Физика металлов и металловедение
- Vol. 122 (11) , 1142-1148
Взаимодействие поверхности ленты с ацетоном и магнитные характеристики аморфного магнитомягкого сплава на основе кобальта
Проведенные исследования показали, что обработка ацетоном ленты аморфного магнитомягкого сплава Co–Ni–Fe–Cr–Mn–Si–B оказывает влияние на ее магнитные характеристики. Оно различно для состояний ленты с разными знаками константы магнитострикции (λs). В состоянии с λs > 0 наблюдается увеличение объема доменов с ортогональной намагниченностью и остроты магнитной текстуры в плоскости ленты; с λs < 0 имеет место уменьшение объема доменов с ортогональной намагниченностью, снижение остроты магнитной текстуры в плоскости ленты и повышение максимальной магнитной проницаемости. Увеличение длительности обработки усиливает ее влияние на объемную компоненту намагниченности и ослабляет воздействие на перераспределение намагниченности в плоскости ленты. Это может быть связано с повышением уровня сжимающих напряжений, индуцированных каталитическим окислением и гидрированием ацетона.
- 1 June 2020
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 121 (6) , 520-525
Effect of Chemically Active Medium on Magnetic Characteristics of Soft Magnetic Co-Based Amorphous Alloy
The interaction of the ribbon surface with acetone and its effect on the magnetic characteristics of ribbon are studied in this work using the example of soft magnetic Co-based AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) amorphous alloy. The studies show the different effect of acetone treatment of ribbon on the magnetization distribution and magnetic permeability of material in states differing in the sign of saturation magnetostriction. The treatment of the ribbon in the state with λs > 0 favors the increase in both the volume of domains with the orthogonal magnetization and the magnetic texture sharpness in the ribbon plane; in the state with λs < 0, the treatment favors the decrease in both the volume of domains with the orthogonal magnetization and magnetic texture sharpness and an increase in the maximum magnetic permeability. This can result from the predominantly planar anisotropic compressive stresses induced in the ribbon by catalytic oxidation and hydrogenation of acetone.
- 1 June 2020
- Published by Pleiades Publishing Ltd in Physics of Metals and Metallography
- Vol. 121 (6) , 520-525
Effect of Chemically Active Medium on Magnetic Characteristics of Soft Magnetic Co-Based Amorphous Alloy
The interaction of the ribbon surface with acetone and its effect on the magnetic characteristics of ribbon are studied in this work using the example of soft magnetic Co-based AMAG-172 (Co–Ni–Fe–Cr–Mn–Si–B) amorphous alloy. The studies show the different effect of acetone treatment of ribbon on the magnetization distribution and magnetic permeability of material in states differing in the sign of saturation magnetostriction. The treatment of the ribbon in the state with λs > 0 favors the increase in both the volume of domains with the orthogonal magnetization and the magnetic texture sharpness in the ribbon plane; in the state with λs < 0, the treatment favors the decrease in both the volume of domains with the orthogonal magnetization and magnetic texture sharpness and an increase in the maximum magnetic permeability. This can result from the predominantly planar anisotropic compressive stresses induced in the ribbon by catalytic oxidation and hydrogenation of acetone.