Analysis and compensation for the effect of the catheter position on image intensities in intravascular optical coherence tomography
Open Access
- 1 December 2016
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (12) , 126005
Abstract
Intravascular optical coherence tomography (IVOCT) is an imaging technique that is used to analyze the underlying cause of cardiovascular disease. Because a catheter is used during imaging, the intensities can be affected by the catheter position. This work aims to analyze the effect of the catheter position on IVOCT image intensities and to propose a compensation method to minimize this effect in order to improve the visualization and the automatic analysis of IVOCT images. The effect of catheter position is modeled with respect to the distance between the catheter and the arterial wall (distance-dependent factor) and the incident angle onto the arterial wall (angle-dependent factor). A light transmission model incorporating both factors is introduced. On the basis of this model, the interaction effect of both factors is estimated with a hierarchical multivariant linear regression model. Statistical analysis shows that IVOCT intensities are significantly affected by both factors with , as either aspect increases the intensity decreases. This effect differs for different pullbacks. The regression results were used to compensate for this effect. Experiments show that the proposed compensation method can improve the performance of the automatic bioresorbable vascular scaffold strut detection.
Keywords
This publication has 23 references indexed in Scilit:
- Automated tissue characterization of in vivo atherosclerotic plaques by intravascular optical coherence tomography imagesBiomedical Optics Express, 2013
- OCT-Based Diagnosis and Management of STEMI Associated With Intact Fibrous CapJACC: Cardiovascular Imaging, 2013
- Automatic stent strut detection in intravascular optical coherence tomographic pullback runsThe International Journal of Cardiovascular Imaging, 2012
- Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography StudiesJACC, 2012
- Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverageThe International Journal of Cardiovascular Imaging, 2011
- Effects of optical beam angle on quantitative optical coherence tomography (OCT) in normal and surface degenerated bovine articular cartilagePhysics in Medicine & Biology, 2010
- Atherosclerotic tissue characterization in vivo by optical coherence tomography attenuation imagingJournal of Biomedical Optics, 2010
- The angle of incidence of the ultrasonic beam: A critical factor for the image quality in intravascular ultrasonographyAmerican Heart Journal, 1993
- Angle-dependent backscatter from the arterial wallUltrasound in Medicine & Biology, 1991
- Angle dependence of ultrasonic backscatter in arterial tissues: a study in vitro.Circulation, 1985