CBCarol A. G. R. Busk
Carol A. G. R. Busk
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carol A. G. R. Busk has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Broersen
Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication - Boudewijn P. F. Lelieveldt
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication Helle Precht
University College Lillebaelt, Conrad Research Center, Odense SØ 5220, Denmark
1 shared publicationJeroen Eggermont
Leiden University Medical Center, Department of Radiology C2-S, Division of Image Processing, P.O. Box 9600, Leiden 2300 RC, The Netherlands
1 shared publication- Jouke Dijkstra
Leiden University Medical Center
1 shared publication Ron Wolterbeek
Leiden University Medical Center, Department of Medical Statistics and Bioinformatics, P.O. Box 9600, Leiden 2300 RC, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 December 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (12) , 126005
Analysis and compensation for the effect of the catheter position on image intensities in intravascular optical coherence tomography
Intravascular optical coherence tomography (IVOCT) is an imaging technique that is used to analyze the underlying cause of cardiovascular disease. Because a catheter is used during imaging, the intensities can be affected by the catheter position. This work aims to analyze the effect of the catheter position on IVOCT image intensities and to propose a compensation method to minimize this effect in order to improve the visualization and the automatic analysis of IVOCT images. The effect of catheter position is modeled with respect to the distance between the catheter and the arterial wall (distance-dependent factor) and the incident angle onto the arterial wall (angle-dependent factor). A light transmission model incorporating both factors is introduced. On the basis of this model, the interaction effect of both factors is estimated with a hierarchical multivariant linear regression model. Statistical analysis shows that IVOCT intensities are significantly affected by both factors with , as either aspect increases the intensity decreases. This effect differs for different pullbacks. The regression results were used to compensate for this effect. Experiments show that the proposed compensation method can improve the performance of the automatic bioresorbable vascular scaffold strut detection.- 1 December 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (12) , 126005
Open AccessAnalysis and compensation for the effect of the catheter position on image intensities in intravascular optical coherence tomography
Intravascular optical coherence tomography (IVOCT) is an imaging technique that is used to analyze the underlying cause of cardiovascular disease. Because a catheter is used during imaging, the intensities can be affected by the catheter position. This work aims to analyze the effect of the catheter position on IVOCT image intensities and to propose a compensation method to minimize this effect in order to improve the visualization and the automatic analysis of IVOCT images. The effect of catheter position is modeled with respect to the distance between the catheter and the arterial wall (distance-dependent factor) and the incident angle onto the arterial wall (angle-dependent factor). A light transmission model incorporating both factors is introduced. On the basis of this model, the interaction effect of both factors is estimated with a hierarchical multivariant linear regression model. Statistical analysis shows that IVOCT intensities are significantly affected by both factors with , as either aspect increases the intensity decreases. This effect differs for different pullbacks. The regression results were used to compensate for this effect. Experiments show that the proposed compensation method can improve the performance of the automatic bioresorbable vascular scaffold strut detection.