Assessment of ammonium fluoride as a mobile phase additive for sensitivity gains in electrospray ionization
Open Access
- 12 October 2023
- journal article
- research article
- Published by Wiley in Analytical Science Advances
- Vol. 4 (11-12) , 347-354
Abstract
Ammonium fluoride has been shown to improve sensitivity when using electrospray ionization (ESI) coupled with mass spectrometry (MS). Recent internal investigation furthered that claim, through the observation of improved sensitivity when analyzing steroid molecules. This work focuses on extending those observations to other small molecules to understand the impact ammonium fluoride has on detection sensitivity with optimized instrument conditions. Using conventional liquid chromatography ESI‐MS we investigated sensitivity differences between ammonium fluoride, formic acid, or ammonium hydroxide as mobile phase additives. Full source optimization was performed for nine compounds at three different organic concentrations (30%, 60%, or 90%) with formic acid, ammonium fluoride, and ammonium hydroxide adjustment. Optimization results were compiled to generate individual methods by compound, polarity, mobile phase, and organic concentration. Flow injection analysis was performed with fully optimized methods to compare compounds across different solvent systems under optimal conditions. Negative ESI data showed 2–22‐fold sensitivity improvements for all compounds with ammonium fluoride. Positive ESI data showed > 1–11‐fold improvement in sensitivity for four of seven compounds and no change for three of seven compounds with ammonium fluoride. Ammonium fluoride improved ESI− sensitivity for all compounds studied when using optimized source conditions. Investigation with ESI+ analyses showed mixed results, with four of seven compounds showing improvement and others showing equivalency or slight loss in sensitivity, suggesting potential sensitivity gains for some analogs with ESI+.Keywords
All Related Versions
This publication has 31 references indexed in Scilit:
- Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatizationJournal of Chromatography B, 2012
- Expanding Coverage of the Metabolome for Global Metabolite ProfilingAnalytical Chemistry, 2011
- Optimization of electrospray interface and quadrupole ion trap mass spectrometer parameters in pesticide liquid chromatography/electrospray ionization mass spectrometry analysisRapid Communications in Mass Spectrometry, 2010
- Enhanced Collision-Induced Decomposition Efficiency and Unraveling of Fragmentation Pathways for Anionic Adducts of Brevetoxins in Negative Ion Electrospray Mass SpectrometryAnalytical Chemistry, 2009
- Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass AnalyzersApplied Spectroscopy Reviews, 2009
- Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additivesJournal of Chromatography B, 2005
- The effect of the mobile phase additives on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography–electrospray mass spectrometryJournal of Chromatography B, 2005
- Optimization strategy for liquid chromatography–electrospray ionization mass spectrometry methodsThe Analyst, 2000
- The silanol group and its role in liquid chromatographyJournal of Chromatography A, 1997
- Factors affecting electrospray ionization of effluents containing trifluoroacetic acid for high-performance liquid chromatography/mass spectrometryAnalytical Chemistry, 1993