  • Mathematically arterialised venous blood is a stable representation of patient acid–base status at steady state following acute transient changes in ventilation

    by Lisha Shastri, Søren Kjærgaard, Peter Søndergaard Thyrrestrup, Stephen Edward Rees, Lars Pilegaard Thomsen

    Hyper- or hypoventilation are commonly occurring stress responses to arterial puncture around the time of blood sampling and have been shown to rapidly alter arterial blood acid–base parameters. This study aimed to evaluate a physiology-based mathematical method to transform peripheral venous blood acid–base values into mathematically arterialised equivalents following acute, transient changes in ventilation. Data from thirty patients scheduled for elective surgery were analysed using the physiology-based method. These data described ventilator changes simulating ‘hyper-’ or ‘hypoventilation’ at arterial puncture and included acid–base status from simultaneously drawn blood samples from arterial and peripheral venous catheters at baseline and following ventilatory change. Venous blood was used to calculate mathematically arterialised equivalents using the physiology-based method; baseline values were analysed using Bland–Altman plots. When compared to baseline, measured arterial and calculated arterialised values at each time point within limits of pH: ± 0.03 and PCO2: ± 0.5 kPa, were considered ‘not different from baseline’. Percentage of values considered not different from baseline were calculated at each sampling timepoint following hyper- and hypoventilation. For the physiological method, bias and limits of agreement for pH and PCO2 were -0.001 (-0.022 to 0.020) and -0.02 (-0.37 to 0.33) kPa at baseline, respectively. 60 s following a change in ventilation, 100% of the mathematically arterialised values of pH and PCO2 were not different from baseline, compared to less than 40% of the measured arterial values at the same timepoint. In clinical situations where transient breath-holding or hyperventilation may compromise the accuracy of arterial blood samples, arterialised venous blood is a stable representative of steady state arterial blood.


  • Open Access

    ESICM LIVES 2020

    by Lisha Shastri, Søren Kjærgaard, Peter Søndergaard Thyrrestrup, Stephen Edward Rees, Lars Pilegaard Thomsen


  • Prospective evaluation of a decision support system for setting inspired oxygen in intensive care patients

    by Dan S. Karbing, Charlotte Allerød, Per Thorgaard, Ann-Maj Carius, Lotte Frilev, Steen Andreassen, Søren Kjærgaard, Stephen E. Rees


  • Open Access

    Reproduction of inert gas and oxygenation data: a comparison of the MIGET and a simple model of pulmonary gas exchange

    by Stephen E. Rees, S. Kjærgaard, S. Andreassen, G. Hedenstierna

    The multiple inert gas elimination technique (MIGET) is the reference method for evaluating pulmonary gas exchange. MIGET includes a complex experimental method and mathematical model, and has not been used routinely in clinical practice. A simpler mathematical model has been proposed, and was shown previously to fit inert gas data from oleic acid damage. This paper explores the capability of this simple model to describe more complex damage, and to calculate oxygenation data upon changing the inspired oxygen fraction (FIO2), comparing these results with those obtained using MIGET. The comparison of oxygenation was done at different ventilator settings and at varying values of FIO2 in order to mimic the clinical conditions that occur in the intensive care unit. The simple model describes inert gas data from heterogeneous lung damage within measurement noise. Model simulations performed using the MIGET and the simple model are comparable, the MIGET model simulating partial pressure of oxygen (PaO2) values on average 0.22 ± 0.59 kPa (±SD) higher than the simple model. Model simulations are also accurate with a difference between model simulated and measured values of PaO2 of 0.33 ± 1.48 kPa (±SD) for the MIGET model and 0.12 ± 1.33 kPa (±SD) for the simple model. This comparability and accuracy was similar over different ventilator settings. The simple model provides a description of lung damage and arterial oxygenation which is comparable to the MIGET, calculating PaO2 with acceptable accuracy and precision over the clinically relevant range of PaO2, and for different values of FIO2, positive end-expiratory pressure (PEEP), and inspiratory-to-expiratory ratio (I:E).


  • Open Access

    Oxygenation within the first 120 h following coronary artery bypass grafting. Influence of systemic hypothermia (32 °C) or normothermia (36 °C) during the cardiopulmonary bypass: a randomized clinical trial

    by B. S. Rasmussen, J. Sollid, S. E. Rees, S. Kjærgaard, D. Murley, E. Toft

    Lung function is often impaired after cardiac surgery performed under cardiopulmonary bypass (CPB). Normothermic CPB has become more common, but it remains unknown whether it reduces post-operative lung function compared with hypothermic CPB. The aim of this study was to investigate oxygenation within the first 120 h after systemic hypothermia and normothermia under CPB. Thirty patients undergoing coronary artery bypass grafting (CABG) were randomized to either hypothermic (32 degrees C) or normothermic (36 degrees C) CPB. Oxygenation was studied by a simple method for the estimation of intrapulmonary shunt and ventilation-perfusion (V/Q) mismatch pre-operatively and 4, 48 and 120 h post-operatively by changing Fio2 in four to six steps. V/Q mismatch was described with DeltaPo2 (normal values, 0-2.38 kPa). Shunt and V/Q mismatch (DeltaPo2) increased post-operatively in both groups (P<0.01), with no differences between the groups, and with the nadir values 48 h after surgery, i.e. shunt of 15% (5.8-25%) and DeltaPo2 of 3.0 kPa (0.8-14 kPa) [values given as median (range)]. Impaired oxygenation is prevalent and prolonged following CABG, with equal intensity after hypothermic and normothermic CPB.