A Comparison of Auditory Evoked Potentials Derived From a Monitor Integrated Module Versus Standard Technique
- 1 April 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Neurosurgical Anesthesiology
- Vol. 21 (2) , 120-126
Abstract
Measurement of brain stem auditory evoked potentials (BAEP) and midlatency auditory evoked potentials (MLAEP) using a new monitor integrated module was compared with an established device. The aim of this study was to evaluate if the new system could replace the more inconvenient established technique. MLAEP and BAEP were obtained from 19 anesthetized male patients using the AEP-Module for Monitor S/5 [GE, Helsinki, Finland (S/5)] and Neuropack 4 mini [Nihon Kohden, Tokyo, Japan (Neuropack)]. Significance of different results was calculated by paired t test. Bias was estimated by Bland-Altman statistics. Latencies of BAEP were significantly shorter and amplitudes of BAEP were significantly higher for Neuropack. Mean latencies of MLAEP (Pa and Nb) were not significantly different (Pa 44.1+/-4.4 ms vs. 41.9+/-5.4 ms/Nb 66.4+/-5.6 ms vs. 62.8+/-6.5 ms), but methods are not interchangeable owing to great variability (Pa -13.16 to 8.94 ms, Nb -19.15 to 11.79 ms). BAEP recorded by S/5 cannot be used for diagnostic interpretation using generally accepted normal values, but can be used for examining changes during the monitoring period. Mean values of Pa and Nb were not significantly different, but values of the S/5 varied above and below the values of Neuropack such that the measurements could not be used for diagnostic interpretation. However, this did not reduce their usefulness for determining adequate hypnosis.Keywords
This publication has 17 references indexed in Scilit:
- Auditory evoked potentialsBest Practice & Research Clinical Anaesthesiology, 2006
- Intraoperative neurophysiological monitoring in pediatric neurosurgery: why, when, how?Child's Nervous System, 2002
- Victims of awarenessActa Anaesthesiologica Scandinavica, 2002
- Electrophysiological monitoring of general intensive care patientsIntensive Care Medicine, 1999
- Evoked responses in anaesthesiaBritish Journal of Anaesthesia, 1998
- Monitoring of the central nervous systemCurrent Opinion in Anaesthesiology, 1998
- Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousnessBritish Journal of Anaesthesia, 1998
- IFCN recommended standards for brain-stem auditory evoked potentials. Report of an IFCN committeeElectroencephalography and Clinical Neurophysiology, 1994
- Auditory Brain Stem Evoked Potentials in Patients with Multiple SclerosisEuropean Neurology, 1980
- ABNORMALITIES OF THE AUDITORY EVOKED POTENTIALS IN PATIENTS WITH MULTIPLE SCLEROSISBrain, 1977