Design and evaluation of an RF front‐end for 9.4 T human MRI
Open Access
- 4 March 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (2) , 594-602
Abstract
At the field strength of 9.4 T, the highest field currently available for human MRI, the wavelength of the MR signals is significantly shorter than the size of the examined structures. Even more than at 7 T, constructive and destructive interferences cause strong inhomogeneities of the B1 field produced by a volume coil, causing shading over large parts of the image. Specialized radio frequency hardware and B1 management methods are required to obtain high‐quality images that take full advantage of the high field strength. Here, the design and characteristics of a radio frequency front‐end especially developed for proton imaging at 9.4 T are presented. In addition to a 16‐channel transceiver array coil, capable of volume transmit mode and independent signal reception, it consists of custom built low noise preamplifiers and TR switches. Destructive interference patterns were eliminated, in virtually the entire brain, using a simple in situ radio frequency phase shimming technique. After mapping the B profile of each transmit channel, a numerical algorithm was used to calculate the appropriate transmit phase offsets needed to obtain a homogeneous excitation field over a user defined region. Between two and three phase settings are necessary to obtain homogeneous images over the entire brain. Magn Reson Med, 2011. &Keywords
This publication has 22 references indexed in Scilit:
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- Optimizing the intrinsic signal‐to‐noise ratio of MRI strip detectorsMagnetic Resonance in Medicine, 2006
- An Inverted-Microstrip Resonator for Human Head Proton MR Imaging at 7 TeslaIEEE Transactions on Biomedical Engineering, 2005
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- Phantom design method for high‐field MRI human systemsMagnetic Resonance in Medicine, 2004
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Functional mapping in the human brain using high magnetic fieldsPhilosophical Transactions of the Royal Society B: Biological Sciences, 1999
- Radiofrequency shielding of surface coils at 4.0 tJournal of Magnetic Resonance Imaging, 1995
- Radiative losses of a birdcage resonatorMagnetic Resonance in Medicine, 1993
- Optimization by Simulated AnnealingScience, 1983