GSG. Shajan

G. Shajan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


G. Shajan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Jens Hoffmann

    High Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany

    5 shared publications
  • Rolf Pohmann

    High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany

    5 shared publications
  • Klaus Scheffler

    High‐Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany

    4 shared publications
  • Christian Mirkes

    High Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany

    2 shared publications
  • Juliane Budde

    Max Planck Institute for Biological Cybernetics, High‐Field Magnetic Resonance Center, Tübingen 72076, Germany

    2 shared publications
  • Kai Buckenmaier

    High Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany

    2 shared publications

Latest Publications

  • Open Access

    Three‐layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla

    by G. Shajan, Christian Mirkes, Kai Buckenmaier, Jens Hoffmann, Rolf Pohmann, Klaus Scheffler

    Purpose: A multinuclei imaging setup with the capability to acquire both sodium (23Na) and proton (1H) signals at 9.4 Tesla is presented. The main objective was to optimize coil performance at the 23Na frequency while still having the ability to acquire satisfactory 1H images.Methods: The setup consisted of a combination of three radio frequency (RF) coils arranged in three layers: the innermost layer was a 27‐channel 23Na receive helmet which was surrounded by a four‐channel 23Na transceiver array. The outer layer consisted of a four‐channel 1H dipole array for B0 shimming and anatomical localization. Transmit and receive performance of the 23Na arrays was compared to a single‐tuned 23Na birdcage resonator.Results: While the transmit efficiency of the 23Na transceiver array was comparable to the birdcage, the 23Na receive array provided substantial signal‐to‐noise ratio (SNR) gain near the surface and comparable SNR in the center. The utility of this customized setup was demonstrated by 23Na images of excellent quality.Conclusion: High SNR, efficient transmit excitation and B0 shimming capability can be achieved for 23Na MRI at 9.4T using novel coil combination. This RF configuration is easily adaptable to other multinuclei applications at ultra high field (≥ 7T). Magn Reson Med 75:906–916, 2016.


  • Three‐layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla

    by G. Shajan, Christian Mirkes, Kai Buckenmaier, Jens Hoffmann, Rolf Pohmann, Klaus Scheffler

    Purpose: A multinuclei imaging setup with the capability to acquire both sodium (23Na) and proton (1H) signals at 9.4 Tesla is presented. The main objective was to optimize coil performance at the 23Na frequency while still having the ability to acquire satisfactory 1H images.Methods: The setup consisted of a combination of three radio frequency (RF) coils arranged in three layers: the innermost layer was a 27‐channel 23Na receive helmet which was surrounded by a four‐channel 23Na transceiver array. The outer layer consisted of a four‐channel 1H dipole array for B0 shimming and anatomical localization. Transmit and receive performance of the 23Na arrays was compared to a single‐tuned 23Na birdcage resonator.Results: While the transmit efficiency of the 23Na transceiver array was comparable to the birdcage, the 23Na receive array provided substantial signal‐to‐noise ratio (SNR) gain near the surface and comparable SNR in the center. The utility of this customized setup was demonstrated by 23Na images of excellent quality.Conclusion: High SNR, efficient transmit excitation and B0 shimming capability can be achieved for 23Na MRI at 9.4T using novel coil combination. This RF configuration is easily adaptable to other multinuclei applications at ultra high field (≥ 7T). Magn Reson Med 75:906–916, 2016.


  • Open Access

    A 16‐channel dual‐row transmit array in combination with a 31‐element receive array for human brain imaging at 9.4 T

    by G. Shajan, Mikhail Kozlov, Jens Hoffmann, Robert Turner, Klaus Scheffler, Rolf Pohmann

    Purpose: Arranging transmit array elements in multiple rows provides an additional degree of freedom to correct B1+ field inhomogeneities and to achieve whole‐brain excitation at ultrahigh field strengths. Receive arrays shaped to the contours of the anatomy increase the signal‐to‐noise ratio of the image. In this work, the advantages offered by the transmit and receive array techniques are combined for human brain imaging at 9.4 T.Methods: A 16‐element dual‐row transmit array and a 31‐element receive array were developed. Based on an accurate numerical model of the transmit array, the deposited power was calculated for different head sizes and positions. The influence of the receive array on the transmit field was characterized. Parallel imaging performance and signal‐to‐noise ratio of the receive array were evaluated.Results: On average, a two fold increase in signal‐to‐noise ratio was observed in the whole‐brain volume when compared with a 16‐channel elliptic microstrip transceiver array. The benefits of combining the two arrays, B1+ shimming in three directions and high receive sensitivity, are demonstrated with high‐resolution in vivo images.Conclusion: The dual‐row transmit array provides whole‐brain coverage at 9.4 T, which, in combination with the helmet‐shaped receive array, is a valuable radio frequency configuration for ultra‐high field magnetic resonance imaging of the human brain. Magn Reson Med 71:870–879, 2014.


  • Open Access

    Human brain imaging at 9.4 T using a tunable patch antenna for transmission

    by Jens Hoffmann, G. Shajan, Juliane Budde, Klaus Scheffler, Rolf Pohmann

    For human brain imaging at ultrahigh fields, the traveling wave concept can provide a more uniform B1+ field over a larger field of view with improved patient comfort compared to conventional volume coils. It suffers, however, from limited transmit efficiency and receive sensitivity and is not readily applicable in systems where the radiofrequency shield is too narrow to allow for unattenuated wave propagation. Here, the near field of a capacitively adjustable patch antenna for excitation is combined with a receive‐only array at 9.4 T. The antenna is designed in compact size and placed in close proximity to the subject to improve the transmit efficiency in narrow bores. Experimental and numerical comparisons to conventional microstrip arrays reveal improved B1+ homogeneity and longitudinal coverage, but at the cost of elevated local specific absorption rate. High‐resolution functional and anatomical images demonstrate the use of this setup for in vivo human brain imaging at 9.4 T. Magn Reson Med, 2013.


  • Rat brain MRI at 16.4T using a capacitively tunable patch antenna in combination with a receive array

    by G. Shajan, Jens Hoffmann, Dávid Z. Balla, Dinesh K. Deelchand, Klaus Scheffler, Rolf Pohmann

    For MRI at 16.4T, with a proton Larmor frequency of 698 MHz, one of the principal RF engineering challenges is to generate a spatially homogeneous transmit field over a larger volume of interest for spin excitation. Constructing volume coils large enough to house a receive array along with the subject and to maintain the quadrature symmetry for different loading conditions is difficult at this frequency. This calls for new approaches to RF coil design for ultra‐high field MR systems. A remotely placed capacitively tunable patch antenna, which can easily be adjusted to different loading conditions, was used to generate a relatively homogeneous excitation field covering a large imaging volume with a transversal profile similar to that of a birdcage coil. Since it was placed in front of the animal, this created valuable free space in the narrow magnet bore around the subject for additional hardware. To enhance the reception sensitivity, the patch antenna was combined with an actively detunable 3‐channel receive coil array. In addition to increased SNR compared to a quadrature transceive surface coil, we were able to get high quality gradient echo and spin‐echo images covering the whole rat brain. Copyright © 2012 John Wiley & Sons, Ltd.


  • Open Access

    Design and evaluation of an RF front‐end for 9.4 T human MRI

    by G. Shajan, Jens Hoffmann, Juliane Budde, Gregor Adriany, Kamil Ugurbil, Rolf Pohmann

    At the field strength of 9.4 T, the highest field currently available for human MRI, the wavelength of the MR signals is significantly shorter than the size of the examined structures. Even more than at 7 T, constructive and destructive interferences cause strong inhomogeneities of the B1 field produced by a volume coil, causing shading over large parts of the image. Specialized radio frequency hardware and B1 management methods are required to obtain high‐quality images that take full advantage of the high field strength. Here, the design and characteristics of a radio frequency front‐end especially developed for proton imaging at 9.4 T are presented. In addition to a 16‐channel transceiver array coil, capable of volume transmit mode and independent signal reception, it consists of custom built low noise preamplifiers and TR switches. Destructive interference patterns were eliminated, in virtually the entire brain, using a simple in situ radio frequency phase shimming technique. After mapping the B profile of each transmit channel, a numerical algorithm was used to calculate the appropriate transmit phase offsets needed to obtain a homogeneous excitation field over a user defined region. Between two and three phase settings are necessary to obtain homogeneous images over the entire brain. Magn Reson Med, 2011. &