Abstract
The chemical regeneration of exhausted granular activated carbon (GAC) from a water treatment plant to produce dialysis water used in hemodialysis treatments for chronic renal disease patients from a general Hospital of Ciego de Avila province, Cuba, was investigated. Activated carbon (AC) exhausted mainly by inorganics (Ca (Ca-chelates), Mg and Na) was regenerated using hydrochloric acid and acetic acid (one regeneration cycle). Solutions of 5%, 10%, 15% and 20%(v/v) as well as four contact times (2 h, 4 h, 6 h and 48 h) for hydrochloric acid and three contact times (2 h, 4 h and 6 h) for acetic acid at 25°C and 1 atm in a dosage of 1 g GAC/10 mL were used. Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES), thermogravimetric analysis (TGA), X-ray absorption technique (XRA) and Scanning Electronic Microscopy (SEM) were used to evaluate the effect of the regeneration on exhausted GAC. Batch and scaled column experiments were developed. Breakthrough curves were obtained to assess the AC’s performances after chemical regeneration. The removal/adsorption capacity towards free chlorine (as disinfection agent) and hardness ions (expressed in mg CaCO3/L) was estimated using the area under the breakthrough curves from scaled columns experiments. The hydrochloric acid arises as the best acidic regenerator; using a concentration of 20%(v/v), regenerated GACs using hydrochloric acid showed the highest desorption rate of inorganics as well as a free chlorine removal performance of around 30% concerning the virgin GAC sample. A new GAC management scheme is proposed for GACs used in the medical industry to improve the sustainability and economics of the water treatment process.Keywords
This publication has 21 references indexed in Scilit:
- Chemical regeneration of granular activated carbon: preliminary evaluation of alternative regenerant solutionsEnvironmental Science: Water Research & Technology, 2020
- X-ray absorption as an alternative method to determine the exhausting degree of activated carbon layers in water treatment system for medical servicesTalanta, 2019
- Chemically modified activated carbon decorated with MnO2 nanocomposites for improving lithium adsorption and recovery from aqueous mediaJournal of Alloys and Compounds, 2019
- Enhanced Adsorption of Aqueous Tetracycline Hydrochloride on Renewable Porous Clay-Carbon Adsorbent Derived from Spent Bleaching Earth via PyrolysisLangmuir, 2019
- Ultrapure water in haemodialysis: a step towards better quality in LebanonEastern Mediterranean Health Journal, 2019
- A review on utilization of wood biomass as a sustainable precursor for activated carbon production and applicationRenewable and Sustainable Energy Reviews, 2018
- A novel X-ray radiography approach for the characterization of granular activated carbons used in the rum productionJournal of Analytical Science and Technology, 2018
- Electrochemical regeneration of field spent GAC from two water treatment plantsWater Research, 2012
- Chemical regeneration of activated carbon used for dye adsorptionJournal of the Taiwan Institute of Chemical Engineers, 2011
- The Determination of Free and Combined Chlorine in Water by the Use of Diethyl‐p‐phenylene DiamineJournal AWWA, 1957