Poly(indole-5-carboxylic acid)/reduced graphene oxide/gold nanoparticles/phage-based electrochemical biosensor for highly specific detection of Yersinia pseudotuberculosis
- 4 March 2021
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 188 (4) , 1-13
Abstract
Yersinia pseudotuberculosis is an enteric bacterium causing yersiniosis in humans. The existing Yersinia pseudotuberculosis detection methods are time-consuming, requiring a sample pretreatment step, and are unable to discriminate live/dead cells. The current work reports a phage-based electrochemical biosensor for rapid and specific detection of Yersinia pseudotuberculosis. The conductive poly(indole-5-carboxylic acid), reduced graphene oxide, and gold nanoparticles are applied for surface modification of the electrode. They possess ultra-high redox stability and retain 97.7% of current response after performing 50 consecutive cycles of cyclic voltammetry.The specific bacteriophages vB_YepM_ZN18 we isolated from hospital sewage water were immobilized on modified electrodes by Au-NH2 bond between gold nanoparticles and phages. The biosensor fabricated with nanomaterials and phages were utilized to detect Yersinia pseudotuberculosis successfully with detection range of 5.30 × 102 to 1.05 × 107 CFU mL−1, detection limit of 3 CFU mL−1, and assay time of 35 min. Moreover, the biosensor can specifically detect live Yersinia pseudotuberculosis without responding to phage-non-host bacteria and dead Yersinia pseudotuberculosis cells. These results suggest that the proposed biosensor is a promising tool for the rapid and selective detection of Yersinia pseudotuberculosis in food, water, and clinical samples.Keywords
Funding Information
- National Key Research and Development Program of China (2017YFC1104402)
This publication has 53 references indexed in Scilit:
- Recent Advances in Bacteriophage Based Biosensors for Food-Borne Pathogen DetectionSensors, 2013
- A Yersinia pestis-specific, lytic phage preparation significantly reduces viable Y. pestis on various hard surfaces experimentally contaminated with the bacteriumBacteriophage, 2012
- Immobilization of rat brain acetylcholinesterase on ZnS and poly(indole-5-carboxylic acid) modified Au electrode for detection of organophosphorus insecticidesBiosensors and Bioelectronics, 2011
- Real‐time multiplex PCR assay for detection of Yersinia pestis and Yersinia pseudotuberculosisAPMIS, 2009
- TaqMan-Based Real-Time PCR Method for Detection of Yersinia pseudotuberculosis in FoodApplied and Environmental Microbiology, 2008
- Transmission of Yersinia pseudotuberculosis in the Pork Production Chain from Farm to SlaughterhouseApplied and Environmental Microbiology, 2008
- Label-free detection of DNA hybridization based on poly(indole-5-carboxylic acid) conducting polymerAnalytica Chimica Acta, 2008
- Broad-Host-Range Yersinia Phage PY100: Genome Sequence, Proteome Analysis of Virions, and DNA Packaging StrategyJournal of Bacteriology, 2008
- Duplex Real-Time SYBR Green PCR Assays for Detection of 17 Species of Food- or Waterborne Pathogens in StoolsJournal of Clinical Microbiology, 2003
- Electrochemically polymerised films of 5-carboxyinodele. Preparation and propertiesJournal of the Chemical Society, Faraday Transactions, 1992