How Sensitive Is the Upper Gastrointestinal Tract to 90Y Radioembolization? A Histologic and Dosimetric Analysis in a Porcine Model
Open Access
- 7 July 2016
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 57 (12) , 1957-1963
Abstract
In 90Y radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in gastrointestinal injury, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed dose endpoints. Methods: Six female pigs underwent transfemoral angiography and infusion of 90Y resin microspheres into arteries supplying part of the gastric wall. Esophagogastroduodenoscopy was performed after 4 weeks to assess interim gastrointestinal health. Animals were monitored for side-effects for 9 weeks following 90Y infusion, after which they were euthanized and their upper gastrointestinal tracts were excised for analysis. Histologic sections were used to map microsphere location and a microdosimetric evaluation was performed to determine the absorbed dose profile within the gastrointestinal wall. Results: 90Y radioembolization dosages from 46.3 to 105.1 MBq were infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1-2 small (2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastrointestinal wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microscopic microsphere distribution confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a first-order estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. Clinical examples of injury from 90Y NTE have likely resulted from relatively large 90Y activities being deposited in small tissue volumes resulting in absorbed doses in excess of 100 Gy.Keywords
This publication has 15 references indexed in Scilit:
- Prospective, Randomized Study of Coil Embolization versus Surefire Infusion System during Yttrium-90 Radioembolization with Resin MicrospheresJournal of Vascular and Interventional Radiology, 2014
- Prophylactic Embolization of the Gastroduodenal and Right Gastric Arteries Is Not Routinely Necessary before Radioembolization with Glass MicrospheresJournal of Vascular and Interventional Radiology, 2013
- Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 RadioembolizationCardioVascular and Interventional Radiology, 2013
- Temporary Balloon Occlusion of the Common Hepatic Artery for Administration of Yttrium-90 Resin Microspheres in a Patient with Patent Hepatoenteric CollateralsJournal of Vascular and Interventional Radiology, 2012
- Patient Selection and Activity Planning Guide for Selective Internal Radiotherapy With Yttrium-90 Resin MicrospheresInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Radiation Dose–Volume Effects in the Stomach and Small BowelInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Recommendations for Radioembolization of Hepatic Malignancies Using Yttrium-90 Microsphere Brachytherapy: A Consensus Panel Report from the Radioembolization Brachytherapy Oncology ConsortiumInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Gastrointestinal Complications Associated with Hepatic Arterial Yttrium-90 Microsphere TherapyJournal of Vascular and Interventional Radiology, 2007
- Dose distribution following selective internal radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- The Skin: Its Structure and Response to Ionizing RadiationInternational Journal of Radiation Biology, 1990