APAlexander S. Pasciak

Alexander S. Pasciak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander S. Pasciak has a total of 59 co-authors. Here are the top co-authors by number of shared publications:

  • Yong C. Bradley

    Department of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA

    6 shared publications
  • Austin C. Bourgeois

    Departments of Radiology, University of Tennessee Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, Tennessee; Department of Radiology, The Medical University of South Carolina, Charleston, South Carolina

    5 shared publications
  • Aravind Arepally

    Piedmont Radiology, Atlanta, Georgia; Interventional Radiology, Vanderbilt School of Medicine, Nashville, Tennessee

    2 shared publications
  • Laurentia Nodit

    Pathology, University of Tennessee Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, Tennessee

    2 shared publications
  • R. Eric Heidel

    Department of Biostatistics, University of Tennessee Graduate School of Medicine, Knoxville, Tennessee

    2 shared publications
  • Aaron Kyle Jones

    Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Tex

    1 shared publication

Latest Publications

  • Open Access

    Correction to: Yttrium-90 radioembolization as a possible new treatment for brain cancer: proof of concept and safety analysis in a canine model

    by Alexander S. Pasciak, Sasicha Manupipatpong, Ferdinand K. Hui, Larry Gainsburg, Rebecca Krimins, M. Christine Zink, Cory F. Brayton, Meaghan Morris, Jaime Sage, Danielle R. Donahue, et al.

    An amendment to this paper has been published and can be accessed via the original article.


  • Open Access

    Yttrium-90 radioembolization as a possible new treatment for brain cancer: proof of concept and safety analysis in a canine model

    by Alexander S. Pasciak, Sasicha Manupipatpong, Ferdinand K. Hui, Larry Gainsburg, Rebecca Krimins, M. Christine Zink, Cory F. Brayton, Meaghan Morris, Jaime Sage, Danielle R. Donahue, et al.

    Purpose: To evaluate the safety, feasibility, and preliminary efficacy of yttrium-90 (90Y) radioembolization (RE) as a minimally invasive treatment in a canine model with presumed spontaneous brain cancers. Materials: Three healthy research dogs (R1–R3) and five patient dogs with spontaneous intra-axial brain masses (P1–P5) underwent cerebral artery RE with 90Y glass microspheres (TheraSphere). 90Y-RE was performed on research dogs from the unilateral internal carotid artery (ICA), middle cerebral artery (MCA), and posterior cerebral artery (PCA) while animals with brain masses were treated from the ICA. Post-treatment 90Y PET/CT was performed along with serial neurological exams by a veterinary neurologist. One month after treatment, research dogs were euthanized and the brains were extracted and sent for microdosimetric and histopathologic analyses. Patient dogs received post-treatment MRI at 1-, 3-, and 6-month intervals with long-term veterinary follow-up. Results: The average absorbed dose to treated tissue in R1–R3 was 14.0, 30.9, and 73.2 Gy, respectively, with maximum doses exceeding 1000 Gy. One month after treatment, research dog pathologic analysis revealed no evidence of cortical atrophy and rare foci consistent with chronic infarcts, e.g., < 2-mm diameter. Absorbed doses to masses in P1–P5 were 45.5, 57.6, 58.1, 45.4, and 64.1 Gy while the dose to uninvolved brain tissue was 15.4, 27.6, 19.2, 16.7, and 33.3 G, respectively. Among both research and patient animals, 6 developed acute neurologic deficits following treatment. However, in all surviving dogs, the deficits were transient resolving between 7 and 33 days post-therapy. At 1 month post-therapy, patient animals showed a 24–94% reduction in mass volume with partial response in P1, P3, and P4 at 6 months post-treatment. While P2 initially showed a response, by 5 months, the mass had advanced beyond pre-treatment size, and the dog was euthanized. Conclusion: This proof of concept demonstrates the technical feasibility and safety of 90Y-RE in dogs, while preliminary, initial data on the efficacy of 90Y-RE as a potential treatment for brain cancer is encouraging.


  • Open Access

    Computational simulation of the predicted dosimetric impact of adjuvant yttrium-90 PET/CT-guided percutaneous ablation following radioembolization

    by Alexander S. Pasciak, Abigail Lin, Christos Georgiades, Laura K. Findeiss, Shannon Kauffman, Yong C. Bradley

    90Y PET/CT post-radioembolization imaging has demonstrated that the distribution of 90Y in a tumor can be non-uniform. Using computational modeling, we predicted the dosimetric impact of post-treatment 90Y PET/CT-guided percutaneous ablation of the portions of a tumor receiving the lowest absorbed dose. A cohort of fourteen patients with non-resectable liver cancer previously treated using 90Y radioembolization were included in this retrospective study. Each patient exhibited potentially under-treated areas of tumor following treatment based on quantitative 90Y PET/CT. 90Y PET/CT was used to guide electrode placement for simulated adjuvant radiofrequency ablation in areas of tumor receiving the lowest dose. The finite element method was used to solve Penne’s bioheat transport equation, coupled with the Arrhenius thermal cell-death model to determine 3D thermal ablation zones. Tumor and unablated tumor absorbed-dose metrics (average dose, D50, D70, D90, V100) following ablation were compared, where D70 is the minimum dose to 70% of tumor and V100 is the fractional tumor volume receiving more than 100 Gy. Compared to radioembolization alone, 90Y radioembolization with adjuvant ablation was associated with predicted increases in all tumor dose metrics evaluated. The mean average absorbed dose increased by 11.2 ± 6.9 Gy. Increases in D50, D70, and D90 were 11.0 ± 6.9 Gy, 13.3 ± 10.9 Gy, and 11.8 ± 10.8 Gy, respectively. The mean increase in V100 was 7.2 ± 4.2%. All changes were statistically significant (P < 0.01). A negative correlation between pre-ablation tumor volume and D50, average dose, and V100 was identified (ρ < − 0.5, P < 0.05) suggesting that adjuvant radiofrequency ablation may be less beneficial to patients with large tumor burdens. This study has demonstrated that adjuvant 90Y PET/CT-guided radiofrequency ablation may improve tumor absorbed-dose metrics. These data may justify a prospective clinical trial to further evaluate this hybrid approach.

  • Bariatric Radioembolization: A Pilot Study on Technical Feasibility and Safety in a Porcine Model

    by Alexander S. Pasciak, Austin C. Bourgeois, Ben E. Paxton, Laurentia Nodit, Patricia N. Coan, Dara Kraitchman, Sandra S. Stinnett, Vijay M. Patel, Yingli Fu, Joleen K. Adams, et al.


  • Open Access

    How Sensitive Is the Upper Gastrointestinal Tract to 90Y Radioembolization? A Histologic and Dosimetric Analysis in a Porcine Model

    by Alexander S Pasciak, Laurentia Nodit, Austin C Bourgeois, B. E. Paxton, Patricia N Coan, Christopher T Clark, M Katherine Tolbert, Joleen K Adams, Aravind Arepally, Yong C Bradley

    In 90Y radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in gastrointestinal injury, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed dose endpoints. Methods: Six female pigs underwent transfemoral angiography and infusion of 90Y resin microspheres into arteries supplying part of the gastric wall. Esophagogastroduodenoscopy was performed after 4 weeks to assess interim gastrointestinal health. Animals were monitored for side-effects for 9 weeks following 90Y infusion, after which they were euthanized and their upper gastrointestinal tracts were excised for analysis. Histologic sections were used to map microsphere location and a microdosimetric evaluation was performed to determine the absorbed dose profile within the gastrointestinal wall. Results: 90Y radioembolization dosages from 46.3 to 105.1 MBq were infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1-2 small (2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastrointestinal wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microscopic microsphere distribution confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a first-order estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. Clinical examples of injury from 90Y NTE have likely resulted from relatively large 90Y activities being deposited in small tissue volumes resulting in absorbed doses in excess of 100 Gy.


  • Open Access

    A Microdosimetric Analysis of Absorbed Dose to Tumor as a Function of Number of Microspheres per Unit Volume in 90Y Radioembolization

    by Alexander S. Pasciak, Austin C. Bourgeois, Yong C. Bradley

    Differences in maximum tolerable absorbed-dose to normal liver between Yttrium-90 (90Y) radioembolization and external beam radiation therapy have been explained by citing differences in absorbed-dose heterogeneity at the microscopic level. We investigated microscopic absorbed-dose heterogeneity in radioembolization as a function of the number of microspheres per unit volume in tumor. The goal was to determine what effect the number of microspheres may have, if any, on tumor control in 90Y radioembolization. METHODS: 90Y PET/CT data was combined with microscopic probability-density functions describing microsphere clustering to provide realistic simulation using Monte Carlo modeling on both a macroscopic and microscopic level. A complete microdosimetric analysis using 100 µm voxels was performed based on 90Y PET/CT data from 19 tumors treated using radioembolization. Simulations were performed with average tumor microsphere number-densities from 200 spheres/mL to 70,000 spheres/mL. Monte Carlo simulations of each tumor and number-density were repeated 20 times to establish standard error. A two-way balanced ANOVA test was used to determine if differences in microsphere number-density affected common tumor dose metrics. RESULTS: Decreasing microsphere-number density resulted in a decrease in D70, the minimum dose to 70% of the tumor. The slope of the dose-volume histogram was also decreased in magnitude with decreasing microsphere number-density in all tumors. Compared to a number-density of 50,000 spheres/mL, decreases in D70 were statistically significant below 20,000 spheres/mL. However, these differences are unlikely to have clinical significance until the number-density decreases below 5,000 spheres/mL. While D70 was decreased at low microsphere number-density, these decreases can be compensated for with an increase in the average tumor absorbed-dose, i.e., by increasing the radioembolization treatment dosage. CONCLUSION: Differences in microsphere number-density in radioembolization may have an effect on microscopic tumor absorbed-dose inhomogeneity. These results may begin to explain differences in treatment planning strategies between Glass and Resin radioembolization devices.


  • Simulation-Based Educational Curriculum for Fluoroscopically Guided Lumbar Puncture Improves Operator Confidence and Reduces Patient Dose

    by Austin R. Faulkner, Austin C. Bourgeois, Yong C. Bradley, Kathleen B. Hudson, R. Eric Heidel, Alexander S. Pasciak


  • Open Access

    The Impact of an Antireflux Catheter on Target Volume Particulate Distribution in Liver-Directed Embolotherapy: A Pilot Study

    by Alexander S. Pasciak, James H. McElmurray, Austin C. Bourgeois, R. Eric Heidel, Yong C. Bradley


  • Open Access

    Time to take the gloves off: the use of radiation reduction gloves can greatly increase patient dose

    by Alexander S. Pasciak, A. Kyle Jones

    Sterile radiation reduction gloves have been widely used over the past several decades in an effort to reduce hand doses during fluoroscopically guided procedures. While multiple studies have quantified the potential dose reduction to the fluoroscope operator from the use of such gloves, possible effects on the patient have not yet been quantified. The aim of this study was to examine the impact on patient dose when radiation reduction gloves are used. The impact on patient dose when using radiation reduction gloves in the field of view (FOV) was evaluated by measuring patient entrance surface dose rates (ESDR) using three C‐arm fluoroscopes for a range of patient sizes and different operating and magnification modes. Multiple measuring fields were used in combination with both peripheral and central glove placement. ESDR were measured with no glove in the FOV, with one radiation reduction glove, and with double gloves in the FOV, to replicate the actions of some fluoroscope operators. Compared to an ungloved hand, the use of a single radiation reduction glove in the measuring field resulted in up to a 2.8‐fold increase in ESDR. The use of double radiation reduction gloves resulted in up to a 4.9‐fold increase in ESDR. In both cases, the increase in ESDR was dependent on the size of the patient and on the operating and magnification modes used, and ranged from no increase up to the aforementioned maximum. When used in the FOV, and particularly within the measuring field, radiation reduction gloves can substantially increase ESDR. This increase in dose, when considered against the relatively small published reduction in dose to the operator's hands, may mean that the increased risks from the use of radiation reduction gloves outweigh the benefits. In any case, hands should not be placed in the FOV if not required by the goals of the procedure.PACS number: 87.59.C‐


  • Open Access

    A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres

    by Alexander S. Pasciak, Austin C. Bourgeois, Yong C. Bradley

    90Y PET/CT following radioembolization has recently been established as a viable diagnostic tool, capable of producing images that are both quantitative and have superior image quality than alternative 90Y imaging modalities. Because radioembolization is assumed to be a permanent implant, it is possible to convert quantitative 90Y PET image sets into data representative of spatial committed absorbed-dose. Multiple authors have performed this transformation using dose-point kernel (DPK) convolution to account for the transport of the high-energy 90Y β- particles. This article explores a technique called the Local Deposition Method (LDM), an alternative to DPK convolution for 90Y image-based dosimetry. The LDM assumes that the kinetic energy from each 90Y β- particle is deposited locally, within the voxel where the decay occurred. Using the combined analysis of phantoms scanned using 90Y PET/CT and ideal mathematical phantoms, an accuracy comparison of DPK convolution and the LDM has been performed. Based on the presented analysis, DPK convolution provides no detectible accuracy benefit over the LDM for 90Y PET-based dosimetry. For PET systems with 90Y resolution poorer than 3.25 mm at full-width and half-max using a small voxel size, the LDM may produce a dosimetric solution that is more accurate than DPK convolution under ideal conditions; however, image noise can obscure some of the perceived benefit. As voxel size increases and resolution decreases, differences between the LDM and DPK convolution are reduced. The LDM method of post-radioembolization dosimetry has the advantage of not requiring additional post-processing. The provided conversion factors can be used to determine committed absorbed-dose using conventional PET image analysis tools. The LDM is a recommended option for routine post-radioembolization 90Y dosimetry based on PET/CT imaging.