A reproducible dynamic phantom for sequence testing in hyperpolarised 13C-magnetic resonance
Authors:
- Rafat ChowdhuryRCRafat Chowdhury
- Marianthi-Vasiliki PapoutsakiMPMarianthi-Vasiliki Papoutsaki
- Christoph A MüllerCMChristoph A Müller
- Lorna SmithLSLorna Smith
- Fiona GongFGFiona Gong
- Max BullockMBMax Bullock
- Harriet RogersHRHarriet Rogers
- Manju MathewMMManju Mathew
- Tom SyerTSTom Syer
- Saurabh SinghSSSaurabh Singh
- Adam RetterARAdam Retter
- Lucy CaseltonLCLucy Caselton
Open Access
- 8 March 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1134) , 20210770
Abstract
Objective: To develop a phantom system which can be integrated with an automated injection system, eliminating the experimental variability that arises with manual injection; for the purposes of pulse sequence testing and metric derivation in hyperpolarised 13C-MR. Methods: The custom dynamic phantom was machined from Ultem and filled with a nicotinamide adenine dinucleotide and lactate dehydrogenase mixture dissolved in phosphate buffered saline. Hyperpolarised [1-13C]-pyruvate was then injected into the phantom (n = 8) via an automated syringe pump and the conversion of pyruvate to lactate monitored through a 13C imaging sequence. Results: The phantom showed low coefficient of variation for the lactate to pyruvate peak signal heights (11.6%) and dynamic area-under curve ratios (11.0%). The variance for the lactate dehydrogenase enzyme rate constant (kP) was also seen to be low at 15.6%. Conclusion: The dynamic phantom demonstrates high reproducibility for quantification of 13C-hyperpolarised MR-derived metrics. Establishing such a phantom is needed to facilitate development of hyperpolarsed 13C-MR pulse sequenced; and moreover, to enable multisite hyperpolarised 13C-MR clinical trials where assessment of metric variability across sites is critical. Advances in knowledge: The dynamic phantom developed during the course of this study will be a useful tool in testing new pulse sequences and standardisation in future hyperpolarised work.Keywords
This publication has 18 references indexed in Scilit:
- Spectrally selective three‐dimensional dynamic balanced steady‐state free precession for hyperpolarized C‐13 metabolic imaging with spectrally selective radiofrequency pulsesMagnetic Resonance in Medicine, 2016
- Use of a Multi-compartment Dynamic Single Enzyme Phantom for Studies of Hyperpolarized Magnetic Resonance AgentsJournal of Visualized Experiments, 2016
- Single shot three‐dimensional pulse sequence for hyperpolarized 13C MRIMagnetic Resonance in Medicine, 2016
- A comparison of quantitative methods for clinical imaging with hyperpolarized 13C‐pyruvateNMR in Biomedicine, 2016
- A Catalyzing Phantom for Reproducible Dynamic Conversion of Hyperpolarized [1-13C]-PyruvatePLOS ONE, 2013
- Metabolic Imaging of Patients with Prostate Cancer Using Hyperpolarized [1- 13 C]PyruvateScience Translational Medicine, 2013
- Use of hyperpolarized [1-13C]pyruvate and [2-13C]pyruvate to probe the effects of the anticancer agent dichloroacetate on mitochondrial metabolism in vivo in the normal ratMagnetic Resonance Imaging, 2012
- Magnetization transfer measurements of exchange between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in a murine lymphomaMagnetic Resonance in Medicine, 2010
- Real-time metabolic imagingProceedings of the National Academy of Sciences, 2006
- Stability of NADPH: effect of various factors on the kinetics of degradation.Clinical Chemistry, 1986