Harriet J. Rogers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Harriet J. Rogers has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Saurabh Singh
Centre for Medical Imaging, University College London, London WC1E 6BT, UK
2 shared publications - Shonit Punwani
Centre for Medical Imaging, University College London, London, UK
2 shared publications - Aaron Oliver-Taylor
Gold Standard Phantoms Limited , London , UK
1 shared publication - Adam Retter
Centre for Medical Imaging, UCL, London, UK
1 shared publication - Aiman Haider
Department of Histopathology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
1 shared publication - Alan Bainbridge
Department of Medical Physics and Biomedical Engineering, University College London Hospital , London, UK
1 shared publication
Latest Publications
- Open Access
- 16 March 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 162, 110782
Test-retest repeatability of ADC in prostate using the multi b-Value VERDICT acquisition
- 16 March 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 162, 110782
Open AccessTest-retest repeatability of ADC in prostate using the multi b-Value VERDICT acquisition
- Open Access
- 1 December 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 623-630
Avoiding Unnecessary Biopsy after Multiparametric Prostate MRI with VERDICT Analysis: The INNOVATE Study
Fractional intracellular volume–derived Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumor analysis of multiparametric MRI findings resulted in better classification of clinic... Background In men suspected of having prostate cancer (PCa), up to 50% of men with positive multiparametric MRI (mpMRI) findings (Prostate Imaging Reporting and Data System [PI-RADS] or Likert scor...
- 1 December 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 623-630
Open AccessAvoiding Unnecessary Biopsy after Multiparametric Prostate MRI with VERDICT Analysis: The INNOVATE Study
Fractional intracellular volume–derived Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumor analysis of multiparametric MRI findings resulted in better classification of clinic... Background In men suspected of having prostate cancer (PCa), up to 50% of men with positive multiparametric MRI (mpMRI) findings (Prostate Imaging Reporting and Data System [PI-RADS] or Likert scor...
- Open Access
- 8 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1134) , 20210770
A reproducible dynamic phantom for sequence testing in hyperpolarised 13C-magnetic resonance
Objective: To develop a phantom system which can be integrated with an automated injection system, eliminating the experimental variability that arises with manual injection; for the purposes of pulse sequence testing and metric derivation in hyperpolarised 13C-MR. Methods: The custom dynamic phantom was machined from Ultem and filled with a nicotinamide adenine dinucleotide and lactate dehydrogenase mixture dissolved in phosphate buffered saline. Hyperpolarised [1-13C]-pyruvate was then injected into the phantom (n = 8) via an automated syringe pump and the conversion of pyruvate to lactate monitored through a 13C imaging sequence. Results: The phantom showed low coefficient of variation for the lactate to pyruvate peak signal heights (11.6%) and dynamic area-under curve ratios (11.0%). The variance for the lactate dehydrogenase enzyme rate constant (kP) was also seen to be low at 15.6%. Conclusion: The dynamic phantom demonstrates high reproducibility for quantification of 13C-hyperpolarised MR-derived metrics. Establishing such a phantom is needed to facilitate development of hyperpolarsed 13C-MR pulse sequenced; and moreover, to enable multisite hyperpolarised 13C-MR clinical trials where assessment of metric variability across sites is critical. Advances in knowledge: The dynamic phantom developed during the course of this study will be a useful tool in testing new pulse sequences and standardisation in future hyperpolarised work.
- 8 March 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1134) , 20210770
Open AccessA reproducible dynamic phantom for sequence testing in hyperpolarised 13C-magnetic resonance
Objective: To develop a phantom system which can be integrated with an automated injection system, eliminating the experimental variability that arises with manual injection; for the purposes of pulse sequence testing and metric derivation in hyperpolarised 13C-MR. Methods: The custom dynamic phantom was machined from Ultem and filled with a nicotinamide adenine dinucleotide and lactate dehydrogenase mixture dissolved in phosphate buffered saline. Hyperpolarised [1-13C]-pyruvate was then injected into the phantom (n = 8) via an automated syringe pump and the conversion of pyruvate to lactate monitored through a 13C imaging sequence. Results: The phantom showed low coefficient of variation for the lactate to pyruvate peak signal heights (11.6%) and dynamic area-under curve ratios (11.0%). The variance for the lactate dehydrogenase enzyme rate constant (kP) was also seen to be low at 15.6%. Conclusion: The dynamic phantom demonstrates high reproducibility for quantification of 13C-hyperpolarised MR-derived metrics. Establishing such a phantom is needed to facilitate development of hyperpolarsed 13C-MR pulse sequenced; and moreover, to enable multisite hyperpolarised 13C-MR clinical trials where assessment of metric variability across sites is critical. Advances in knowledge: The dynamic phantom developed during the course of this study will be a useful tool in testing new pulse sequences and standardisation in future hyperpolarised work.
- Open Access
- 2 July 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 34 (2) , 261-271
Comparison of models of diffusion in Wilms’ tumours and normal contralateral renal tissue
Objective: ADC (Apparent Diffusion Coefficient) derived from Diffusion-Weighted Imaging (DWI) has shown promise as a non-invasive quantitative imaging biomarker in Wilms’ tumours. However, many non-Gaussian models could be applied to DWI. This study aimed to compare the suitability of four diffusion models (mono exponential, IVIM [Intravoxel Incoherent Motion], stretched exponential, and kurtosis) in Wilms’ tumours and the unaffected contralateral kidneys. Materials and methods: DWI data were retrospectively reviewed (110 Wilms’ tumours and 75 normal kidney datasets). The goodness of fit for each model was measured voxel-wise using Akaike Information Criteria (AIC). Mean AIC was calculated for each tumour volume (or contralateral normal kidney tissue). One-way ANOVAs with Greenhouse–Geisser correction and post hoc tests using the Bonferroni correction evaluated significant differences between AIC values; the lowest AIC indicating the optimum model. Results: IVIM and stretched exponential provided the best fits to the Wilms’ tumour DWI data. IVIM provided the best fit for the normal kidney data. Mono exponential was the least appropriate fitting method for both Wilms’ tumour and normal kidney data. Discussion: The diffusion weighted signal in Wilms’ tumours and normal kidney tissue does not exhibit a mono-exponential decay and is better described by non-Gaussian models of diffusion.
- 2 July 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 34 (2) , 261-271
Open AccessComparison of models of diffusion in Wilms’ tumours and normal contralateral renal tissue
Objective: ADC (Apparent Diffusion Coefficient) derived from Diffusion-Weighted Imaging (DWI) has shown promise as a non-invasive quantitative imaging biomarker in Wilms’ tumours. However, many non-Gaussian models could be applied to DWI. This study aimed to compare the suitability of four diffusion models (mono exponential, IVIM [Intravoxel Incoherent Motion], stretched exponential, and kurtosis) in Wilms’ tumours and the unaffected contralateral kidneys. Materials and methods: DWI data were retrospectively reviewed (110 Wilms’ tumours and 75 normal kidney datasets). The goodness of fit for each model was measured voxel-wise using Akaike Information Criteria (AIC). Mean AIC was calculated for each tumour volume (or contralateral normal kidney tissue). One-way ANOVAs with Greenhouse–Geisser correction and post hoc tests using the Bonferroni correction evaluated significant differences between AIC values; the lowest AIC indicating the optimum model. Results: IVIM and stretched exponential provided the best fits to the Wilms’ tumour DWI data. IVIM provided the best fit for the normal kidney data. Mono exponential was the least appropriate fitting method for both Wilms’ tumour and normal kidney data. Discussion: The diffusion weighted signal in Wilms’ tumours and normal kidney tissue does not exhibit a mono-exponential decay and is better described by non-Gaussian models of diffusion.
- Open Access
- 17 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4141-4149
An alternative approach to contrast-enhanced imaging: diffusion-weighted imaging and T1-weighted imaging identifies and quantifies necrosis in Wilms tumour
Objectives Volume of necrosis in Wilms tumour is informative of chemotherapy response. Contrast-enhanced T1-weighted MRI (T1w) provides a measure of necrosis using gadolinium. This study aimed to develop a non-invasive method of identifying non-enhancing (necrotic) tissue in Wilms tumour. Methods In this single centre, retrospective study, post-chemotherapy MRI data from 34 Wilms tumour patients were reviewed (March 2012–March 2017). Cases with multiple b value diffusion-weighted imaging (DWI) and T1w imaging pre- and post-gadolinium were included. Fractional T1 enhancement maps were generated from the gadolinium T1w data. Multiple linear regression determined whether fitted parameters from a mono-exponential model (ADC) and bi-exponential model (IVIM – intravoxel incoherent motion) (D, D*, f) could predict fractional T1 enhancement in Wilms tumours, using normalised pre-gadolinium T1w (T1wnorm) signal as an additional predictor. Measured and predicted fractional enhancement values were compared using the Bland-Altman plot. An optimum threshold for separating necrotic and viable tissue using fractional T1 enhancement was established using ROC. Results ADC and D (diffusion coefficient) provided the strongest predictors of fractional T1 enhancement in tumour tissue (p < 0.001). Using the ADC-T1wnorm model (adjusted R2 = 0.4), little bias (mean difference = − 0.093, 95% confidence interval = [− 0.52, 0.34]) was shown between predicted and measured values of fractional enhancement and analysed via the Bland-Altman plot. The optimal threshold for differentiating viable and necrotic tissue was 33% fractional T1 enhancement (based on measured values, AUC = 0.93; sensitivity = 85%; specificity = 90%). Conclusions Combining ADC and T1w imaging predicts enhancement in Wilms tumours and reliably identifies and measures necrotic tissue without gadolinium. Key Points • Alternative method to identify necrotic tissue in Wilms tumour without using contrast agents but rather using diffusion and T 1 weighted MRI. • A method is presented to visualise and quantify necrotic tissue in Wilms tumour without contrast. • The proposed method has the potential to reduce costs and burden to Wilms tumour patients who undergo longitudinal follow-up imaging as contrast agents are not used.
- 17 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4141-4149
Open AccessAn alternative approach to contrast-enhanced imaging: diffusion-weighted imaging and T1-weighted imaging identifies and quantifies necrosis in Wilms tumour
Objectives Volume of necrosis in Wilms tumour is informative of chemotherapy response. Contrast-enhanced T1-weighted MRI (T1w) provides a measure of necrosis using gadolinium. This study aimed to develop a non-invasive method of identifying non-enhancing (necrotic) tissue in Wilms tumour. Methods In this single centre, retrospective study, post-chemotherapy MRI data from 34 Wilms tumour patients were reviewed (March 2012–March 2017). Cases with multiple b value diffusion-weighted imaging (DWI) and T1w imaging pre- and post-gadolinium were included. Fractional T1 enhancement maps were generated from the gadolinium T1w data. Multiple linear regression determined whether fitted parameters from a mono-exponential model (ADC) and bi-exponential model (IVIM – intravoxel incoherent motion) (D, D*, f) could predict fractional T1 enhancement in Wilms tumours, using normalised pre-gadolinium T1w (T1wnorm) signal as an additional predictor. Measured and predicted fractional enhancement values were compared using the Bland-Altman plot. An optimum threshold for separating necrotic and viable tissue using fractional T1 enhancement was established using ROC. Results ADC and D (diffusion coefficient) provided the strongest predictors of fractional T1 enhancement in tumour tissue (p < 0.001). Using the ADC-T1wnorm model (adjusted R2 = 0.4), little bias (mean difference = − 0.093, 95% confidence interval = [− 0.52, 0.34]) was shown between predicted and measured values of fractional enhancement and analysed via the Bland-Altman plot. The optimal threshold for differentiating viable and necrotic tissue was 33% fractional T1 enhancement (based on measured values, AUC = 0.93; sensitivity = 85%; specificity = 90%). Conclusions Combining ADC and T1w imaging predicts enhancement in Wilms tumours and reliably identifies and measures necrotic tissue without gadolinium. Key Points • Alternative method to identify necrotic tissue in Wilms tumour without using contrast agents but rather using diffusion and T 1 weighted MRI. • A method is presented to visualise and quantify necrotic tissue in Wilms tumour without contrast. • The proposed method has the potential to reduce costs and burden to Wilms tumour patients who undergo longitudinal follow-up imaging as contrast agents are not used.