Effects of different contacting pressure on the transfer function between finger photoplethysmographic and radial blood pressure waveforms
Authors:
- 8 June 2011
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 225 (6) , 575-583
Abstract
Background: The blood pressure (BP) waveform is suggested to reflect the whole-body blood supply distribution, but its non-invasive assessment is not sufficiently user friendly for practical applications. The present authors studied the correlation between BP and photo-plethysmography (PPG) waveforms, with the aim of determining the optimal range for contact pressure stimulation (PS) to produce a reliable transfer function in their harmonic parameters. Methods: Finger PPG and radial-artery BP signals were measured simultaneously and non-invasively on healthy volunteers (n = 45). PS of 0–200 mmHg was applied to the finger, and 1 min data sequences were recorded. In frequency-domain analysis, linear regression was applied to the calculated amplitude ratios or the first five harmonics between BP and PPG waveforms. Results: In the 60 mmHg-PS group, the BP–PPG regression of amplitude ratios was highest, and the agreements between them were also the best verified by Bland–Altman analysis. Conclusion: In the present study, frequency-domain analysis was performed to study the correlation between BP and PPG waveforms. Differences in pressure-induced-vasodilation responses underlie the different BP-PPG waveform correlations obtained by applying different PSs. The non-invasively derived PPG parameters might help to provide an easier method to acquire the radial-artery BP waveform, and hence broaden the application of BP waveform analysis.Keywords
This publication has 19 references indexed in Scilit:
- Spectral Analysis of Finger Photoplethysmographic Waveform Variability in a Model of Mild to Moderate HaemorrhageJournal of Clinical Monitoring and Computing, 2008
- The relationship between the photoplethysmographic waveform and systemic vascular resistanceJournal of Clinical Monitoring and Computing, 2007
- Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in ratsPhysiological Measurement, 2006
- Association of Risk Factors With Increased Pulse Wave Velocity Detected by a Novel Method Using Dual-Channel PhotoplethysmographyAmerican Journal of Hypertension, 2005
- Clinical measurement of arterial stiffness obtained from noninvasive pressure waveformsAmerican Journal of Hypertension, 2005
- The effect of contacting force on photoplethysmographic signalsPhysiological Measurement, 2004
- How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients?Anesthesia & Analgesia, 2001
- Effect of Acupuncture at Hsien-Ku (St-43) on the Pulse Spectrum and a Discussion of the Evidence for the Frequency Structure of Chinese MedicineThe American Journal of Chinese Medicine, 2000
- Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniquesPhysiological Measurement, 1999
- Verylow frequency variability in arterial blood pressure and blood volume pulseMedical & Biological Engineering & Computing, 1999