Evaluation of a Force‐Control Experimental Method to Perform Unconstrained Load‐Induced Subsidence Testing of Spinal Interbody Implants
Open Access
Abstract
Introduction: Intervertebral body fusion devices (“interbody cages”) used in spinal surgeries are susceptible to axial and/or rotational subsidence into the underlying vertebral bone. Experimental testing standards to examine implant subsidence, such as ASTM F2267, simplify the implant loading conditions and vertebral bone materials for ease of use and repeatability. Yet, the ability to assess clinically relevant risk of rotational subsidence with these methods is limited. Methods: The present work aimed to develop and evaluate a novel force‐control (FC) test method for performing unconstrained load‐induced implant subsidence into a heterogeneous material interface. The developed method was compared to the ASTM F2267 method, which uses a lubricated ball‐and‐socket joint, using the AMTI VIVO joint motion simulator to apply unconstrained loading up to 4 kN. Subsidence testing was performed on two different polyurethane (PU) foam densities (rigid 20 and 30 PCF) sandwiched together providing a heterogeneous boundary interface to induce implant rotation into the less dense foam. Results: Axial and rotational subsidence values varied significantly between the two test methods ( p < 0.05). Unconstrained axial compression up to 4 kN yielded, on average, 2.5 ± 0.4 mm of axial subsidence for ASTM‐based setup compared to 4.8 ± 0.6 mm for the FC setup. The ASTM‐based setup had an average implant rotation of 2.8° ± 0.5°, in contrast to the FC setup, with an average of 18.0° ± 0.9°. Additionally, the experimental FC results had good agreement with a computational finite element model of the same FC setup and PU foam materials. Conclusions: This new FC method for unconstrained load‐induced subsidence testing demonstrates potential improvements in consideration for rotational implant subsidence and the associated clinical burden in spinal surgery.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Institute of Musculoskeletal Health and Arthritis
This publication has 38 references indexed in Scilit:
- Yield strain behavior of trabecular boneJournal of Biomechanics, 1998
- Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone densityEuropean Spine Journal, 1998
- Does the thickness of the vertebral subchondral bone reflect the composition of the intervertebral disc?European Spine Journal, 1997
- Postfailure compressive behavior of tibial trabecular bone in three anatomic directionsJournal of Biomedical Materials Research, 1996
- Characterization of three formulations of a synthetic foam as models for a range of human cancellous bone typesJournal of Applied Biomaterials, 1995
- Trabecular bone modulus and strength can depend on specimen geometryJournal of Biomechanics, 1993
- Mechanics of Interbody Spinal FusionSpine, 1993
- Tensile and compressive properties of cancellous boneJournal of Biomechanics, 1991
- The mechanical properties of trabecular bone: Dependence on anatomic location and functionJournal of Biomechanics, 1987
- The mechanical behaviour of cancellous boneJournal of Biomechanics, 1985