Stewart McLachlin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stewart McLachlin has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Cari Marisa Whyne
Faculty of Engineering, Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
4 shared publications - Michael Hardisty
Division of Orthopaedic Surgery, University of Toronto, 149 College Street, Toronto, ON M5T 1P5, Canada
4 shared publications Claire Thompson
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
3 shared publicationsMartine McGregor
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
3 shared publications- Rémy Benais
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
3 shared publications - Alexander Wong
Department of System Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada
2 shared publications
Latest Publications
- Open Access
- 30 August 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (10)
Is direct oxidative damage of bone collagen associated with poor human cortical bone tissue fracture resistance?
The limitations of clinical X-ray-based tools and fracture risk assessment tools, such as FRAX, particularly for disease groups, including type 2 diabetes (T2D) and CKD, suggest that important determinants of bone fracture resistance are not assessed. One such determinant is the bone collagen network, whose nativity and connectivity contribute to cortical bone fracture resistance, but whose degradation mechanisms remain unclear. Oxidative damage to the collagen network, driven by oxidative stress, has been proposed as a contributing factor. Two pathways are recognized: an indirect pathway involving glycoxidation and advanced glycation end-product formation, examined in a precursor study, and a direct pathway, examined herein, involving protein fragmentation and amino acid side chain modifications, such as carbonylation. To investigate the direct pathway, bulk collagen carbonyl content (measured using a fluorescence-based assay and normalized to collagen content) and intact collagen α-chain content (the opposite of α-chain fragmentation and measured via α-chain band intensities using gel electrophoresis) were quantified ex vivo using cortical bone specimens from 80 human donors with and without T2D and/or CKD. Relationships with fracture toughness and other bone quality measures from a precursor study were assessed using Spearman correlations and multiple linear regression. Bulk collagen carbonyl content was not directly associated with collagen network connectivity or cortical bone fracture toughness. In contrast, intact collagen α-chain content emerged as an independent explanatory variable for stable crack-growth fracture toughness measures (adj-R2 = 46.3%, p = .028) and was negatively associated with bulk collagen carbonyl content (r = −0.37, p < .001). These findings suggest that collagen α-chain integrity may provide insight into variation in cortical bone fracture resistance, whereas bulk collagen carbonyl content did not support the hypothesized direct oxidative damage pathway in this donor cohort.
- 30 August 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (10)
Open AccessIs direct oxidative damage of bone collagen associated with poor human cortical bone tissue fracture resistance?
The limitations of clinical X-ray-based tools and fracture risk assessment tools, such as FRAX, particularly for disease groups, including type 2 diabetes (T2D) and CKD, suggest that important determinants of bone fracture resistance are not assessed. One such determinant is the bone collagen network, whose nativity and connectivity contribute to cortical bone fracture resistance, but whose degradation mechanisms remain unclear. Oxidative damage to the collagen network, driven by oxidative stress, has been proposed as a contributing factor. Two pathways are recognized: an indirect pathway involving glycoxidation and advanced glycation end-product formation, examined in a precursor study, and a direct pathway, examined herein, involving protein fragmentation and amino acid side chain modifications, such as carbonylation. To investigate the direct pathway, bulk collagen carbonyl content (measured using a fluorescence-based assay and normalized to collagen content) and intact collagen α-chain content (the opposite of α-chain fragmentation and measured via α-chain band intensities using gel electrophoresis) were quantified ex vivo using cortical bone specimens from 80 human donors with and without T2D and/or CKD. Relationships with fracture toughness and other bone quality measures from a precursor study were assessed using Spearman correlations and multiple linear regression. Bulk collagen carbonyl content was not directly associated with collagen network connectivity or cortical bone fracture toughness. In contrast, intact collagen α-chain content emerged as an independent explanatory variable for stable crack-growth fracture toughness measures (adj-R2 = 46.3%, p = .028) and was negatively associated with bulk collagen carbonyl content (r = −0.37, p < .001). These findings suggest that collagen α-chain integrity may provide insight into variation in cortical bone fracture resistance, whereas bulk collagen carbonyl content did not support the hypothesized direct oxidative damage pathway in this donor cohort.
- Open Access
- 20 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 2084
Recurrence with Correlation Network for Medical Image Registration
This work presents Recurrence with Correlation Network(RWCNet), a novel multi-scale recurrent neural network architecture for medical image registration that integrates core principles from optical flow, including correlation volume computation and inference-time instance optimization. In evaluations on the large-displacement National Lung Screening Test (NLST) dataset, RWCNet exhibited superior performance (total registration error (TRE) of 2.11 mm) compared to other deep learning alternatives, and achieved results on par with variational optimization techniques. In contrast, on the OASIS dataset, which is characterized by smaller displacements, RWCNet achieved an average Dice similarity of 81.7%, representing only a modest improvement over other multi-scale deep learning models. Ablation experiments showed that multi-scale features consistently improved performance, whereas the correlation volume, number of recurrent steps, and inference-time instance optimization had large impacts on performance within the large-displacement NLST dataset. The performance of RWCNet compared to approaches that use instance optimization show that deep learning-based methods can find local minima that escape instance optimization methods. The results highlight the need for algorithm hyperparameter selection that adjusts with the dataset characteristics. RWCNet’s promising results may improve registration accuracy and computation efficiency, enabling many potential applications such as treatment planning, intra-procedural guidance, and longitudinal monitoring.
- 20 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 2084
Open AccessRecurrence with Correlation Network for Medical Image Registration
This work presents Recurrence with Correlation Network(RWCNet), a novel multi-scale recurrent neural network architecture for medical image registration that integrates core principles from optical flow, including correlation volume computation and inference-time instance optimization. In evaluations on the large-displacement National Lung Screening Test (NLST) dataset, RWCNet exhibited superior performance (total registration error (TRE) of 2.11 mm) compared to other deep learning alternatives, and achieved results on par with variational optimization techniques. In contrast, on the OASIS dataset, which is characterized by smaller displacements, RWCNet achieved an average Dice similarity of 81.7%, representing only a modest improvement over other multi-scale deep learning models. Ablation experiments showed that multi-scale features consistently improved performance, whereas the correlation volume, number of recurrent steps, and inference-time instance optimization had large impacts on performance within the large-displacement NLST dataset. The performance of RWCNet compared to approaches that use instance optimization show that deep learning-based methods can find local minima that escape instance optimization methods. The results highlight the need for algorithm hyperparameter selection that adjusts with the dataset characteristics. RWCNet’s promising results may improve registration accuracy and computation efficiency, enabling many potential applications such as treatment planning, intra-procedural guidance, and longitudinal monitoring.
- Open Access
- 30 January 2026
- Published by MDPI AG in Preprints.org
Recurrence with Correlation Network for Medical Image Registration
This work presents Recurrence with Correlation Network (RWCNet), a novel multi-scale recurrent neural network architecture for medical image registration that integrates core principles from optical flow, including correlation volume computation and inference-time instance optimization. In evaluations on the large-displacement National Lung Screening Test (NLST) dataset, which features large displacements, RWCNet exhibited superior performance (total registration error (TRE) of 2.11mm) to deep learning alternatives, and on par results with variational optimization techniques. In contrast, on the OASIS dataset characterized by smaller displacements, RWCNet's results (average dice similarity of 81.7\%) were superior to variational optimization techniques and showed a small improvement over other multi-scale deep learning models. Ablation experiments showed that multi-scale features consistently improved performance, where as the correlation volume, number of recurrent steps, and inference-time instance optimization only had large positive impacts on performance in the NLST dataset. The performance of RWCNet compared to approaches that use instance optimzation show that deep learning based methods can find local minima that escape instance optimization methods. The results highlight the need for algorithm hyperparameter selection that adjusts with the dataset characteristics. RWCNet's promising results may imporve registration performance and the speed of computation, allowing many potential applications including, treatment planning, intra-procedural guidance, and longitudinal monitoring.
- 30 January 2026
- Published by MDPI AG in Preprints.org
Open AccessRecurrence with Correlation Network for Medical Image Registration
This work presents Recurrence with Correlation Network (RWCNet), a novel multi-scale recurrent neural network architecture for medical image registration that integrates core principles from optical flow, including correlation volume computation and inference-time instance optimization. In evaluations on the large-displacement National Lung Screening Test (NLST) dataset, which features large displacements, RWCNet exhibited superior performance (total registration error (TRE) of 2.11mm) to deep learning alternatives, and on par results with variational optimization techniques. In contrast, on the OASIS dataset characterized by smaller displacements, RWCNet's results (average dice similarity of 81.7\%) were superior to variational optimization techniques and showed a small improvement over other multi-scale deep learning models. Ablation experiments showed that multi-scale features consistently improved performance, where as the correlation volume, number of recurrent steps, and inference-time instance optimization only had large positive impacts on performance in the NLST dataset. The performance of RWCNet compared to approaches that use instance optimzation show that deep learning based methods can find local minima that escape instance optimization methods. The results highlight the need for algorithm hyperparameter selection that adjusts with the dataset characteristics. RWCNet's promising results may imporve registration performance and the speed of computation, allowing many potential applications including, treatment planning, intra-procedural guidance, and longitudinal monitoring.
- Open Access
- 4 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113054
Comparison of six degree-of-freedom pure moment and non-uniform, physiologically-derived spinal loading at quasi-static and dynamic rates using a six-axis joint motion simulator
- 4 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113054
Open AccessComparison of six degree-of-freedom pure moment and non-uniform, physiologically-derived spinal loading at quasi-static and dynamic rates using a six-axis joint motion simulator
- Open Access
- 3 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113053
Experimental simulation of cyclic, six degree-of-freedom, gait and sit-to-stand loading waveforms using a six-axis joint motion simulator
- 3 November 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 194, 113053
Open AccessExperimental simulation of cyclic, six degree-of-freedom, gait and sit-to-stand loading waveforms using a six-axis joint motion simulator
- Open Access
- 31 October 2025
- Published by University of Waterloo in Proceedings of the Holistic Innovation in Additive Manufacturing (HI-AM) Conference
- Vol. 1 (1)
Design and evaluation of surface conformance in additively manufactured spinal reconstruction implants
Spinal implant surface conformance with the underlying bone is often critical to the long-term success of spinal surgeries; however, most spinal implants have a limited ability to match the organic surface profile of the vertebral endplate. To address this challenge, this study aimed to evaluate the surface conformance of additively manufactured lumbar intervertebral cages based on bone contact area and pressure distribution. Two lateral lumbar interbody fusion (LLIF) devices with either a solid or latticed core were designed for additive manufacturing (AM). The two implants were manufactured using SLA in resin with mechanical properties similar to polyether-ether-ketone (PEEK) and in a titanium alloy (Ti64) using laser powder bed fusion. Mechanical testing occurred on three sets of polyurethane Sawbones® machined to simulate a non-uniform vertebral endplate bone. Contact area and pressure distribution were measured using the Tekscan thin film sensor under lumbar compressive waveforms applied via an AMTI VIVO system. Conventional solid implants had an average surface coverage of 19% and 16%, 1 mm of displacement motion each, and peak pressure of 4.1 to 4.8 MPa, for resin and titanium respectively. The gyroid latticed implant had 13% and 11% surface coverage, 1.46 mm and 1 mm displacement motion, and lower of peak pressure for resin and titanium respectively. These results are consistent with previous studies which found that matching the implant to the vertebral endplate stiffness reduces risks of implant subsidence. In conclusion, this study provides preliminary support for the use of AM in tailoring implant design to conform to the endplate geometry. Future work should look to evaluate surface conformance in other designs as well as consideration for testing under fatigue loading conditions.
- 31 October 2025
- Published by University of Waterloo in Proceedings of the Holistic Innovation in Additive Manufacturing (HI-AM) Conference
- Vol. 1 (1)
Open AccessDesign and evaluation of surface conformance in additively manufactured spinal reconstruction implants
Spinal implant surface conformance with the underlying bone is often critical to the long-term success of spinal surgeries; however, most spinal implants have a limited ability to match the organic surface profile of the vertebral endplate. To address this challenge, this study aimed to evaluate the surface conformance of additively manufactured lumbar intervertebral cages based on bone contact area and pressure distribution. Two lateral lumbar interbody fusion (LLIF) devices with either a solid or latticed core were designed for additive manufacturing (AM). The two implants were manufactured using SLA in resin with mechanical properties similar to polyether-ether-ketone (PEEK) and in a titanium alloy (Ti64) using laser powder bed fusion. Mechanical testing occurred on three sets of polyurethane Sawbones® machined to simulate a non-uniform vertebral endplate bone. Contact area and pressure distribution were measured using the Tekscan thin film sensor under lumbar compressive waveforms applied via an AMTI VIVO system. Conventional solid implants had an average surface coverage of 19% and 16%, 1 mm of displacement motion each, and peak pressure of 4.1 to 4.8 MPa, for resin and titanium respectively. The gyroid latticed implant had 13% and 11% surface coverage, 1.46 mm and 1 mm displacement motion, and lower of peak pressure for resin and titanium respectively. These results are consistent with previous studies which found that matching the implant to the vertebral endplate stiffness reduces risks of implant subsidence. In conclusion, this study provides preliminary support for the use of AM in tailoring implant design to conform to the endplate geometry. Future work should look to evaluate surface conformance in other designs as well as consideration for testing under fatigue loading conditions.
- Open Access
- 31 October 2025
- Published by University of Waterloo in Proceedings of the Holistic Innovation in Additive Manufacturing (HI-AM) Conference
- Vol. 1 (1)
Design and mechanical analysis of additively manufactured primitive flexures
In the design of compliant mechanisms, thin flexural members, consisting of bends and curves, can be used to produce a controlled path of rotation under load, which could benefit the design of cervical artificial disc replacements (c-ADR) for example to improve compliance and avoid adjacent segment degeneration. However, to date, there is little literature to characterize the design and mechanical properties of additively manufactured flexural members, limiting crucial data needed to inform implant design. To address this knowledge gap, the goal of this work is to design and additively manufacture a family of primitive flexures to explore how different design features affect the resulting mechanical response under load. Several flexure primitive design features were varied within a common 3-prong flexure component design, including flexure thickness, overhang angle, and number of bends. The response of these designs was then analyzed through applied loading (non-destructive cyclic bending and compression to failure) based on a targeted application of a compliant mechanism for cervical artificial disc replacements. The ability to realize complex parts with latticed or flexible features has value in improving compliance in orthopaedic applications. The primitive flexure designs were printed using Ti6Al4V on the EOS M290 laser powder bed fusion system. For mechanical testing, the flexures were printed between custom-designed endplates to attach to the AMTI VIVO joint motion simulator. The deformation response was captured using the ARAMIS 3D digital image correlation system. Testing results indicated that thicknesses of at least 1mm were required in Ti6Al4V flexures to replicate the axial compressive stiffness in the cervical spine. Introduction of compliant flexure zones led to a negligible reduction in stiffness, while increasing structure compliance in compression and rotation.
- 31 October 2025
- Published by University of Waterloo in Proceedings of the Holistic Innovation in Additive Manufacturing (HI-AM) Conference
- Vol. 1 (1)
Open AccessDesign and mechanical analysis of additively manufactured primitive flexures
In the design of compliant mechanisms, thin flexural members, consisting of bends and curves, can be used to produce a controlled path of rotation under load, which could benefit the design of cervical artificial disc replacements (c-ADR) for example to improve compliance and avoid adjacent segment degeneration. However, to date, there is little literature to characterize the design and mechanical properties of additively manufactured flexural members, limiting crucial data needed to inform implant design. To address this knowledge gap, the goal of this work is to design and additively manufacture a family of primitive flexures to explore how different design features affect the resulting mechanical response under load. Several flexure primitive design features were varied within a common 3-prong flexure component design, including flexure thickness, overhang angle, and number of bends. The response of these designs was then analyzed through applied loading (non-destructive cyclic bending and compression to failure) based on a targeted application of a compliant mechanism for cervical artificial disc replacements. The ability to realize complex parts with latticed or flexible features has value in improving compliance in orthopaedic applications. The primitive flexure designs were printed using Ti6Al4V on the EOS M290 laser powder bed fusion system. For mechanical testing, the flexures were printed between custom-designed endplates to attach to the AMTI VIVO joint motion simulator. The deformation response was captured using the ARAMIS 3D digital image correlation system. Testing results indicated that thicknesses of at least 1mm were required in Ti6Al4V flexures to replicate the axial compressive stiffness in the cervical spine. Introduction of compliant flexure zones led to a negligible reduction in stiffness, while increasing structure compliance in compression and rotation.
- Open Access
- 29 October 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 131, 106692
Comparison of pedicle screw loosening under uniaxial and multiaxial loading
- 29 October 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 131, 106692
Open AccessComparison of pedicle screw loosening under uniaxial and multiaxial loading
- 25 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107238
Micro finite element analysis of vertebrae using zero-thickness cohesive elements represents post-failure fracture patterns
- 25 October 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 173, 107238
Micro finite element analysis of vertebrae using zero-thickness cohesive elements represents post-failure fracture patterns
- Open Access
Evaluation of a Force‐Control Experimental Method to Perform Unconstrained Load‐Induced Subsidence Testing of Spinal Interbody Implants
Introduction: Intervertebral body fusion devices (“interbody cages”) used in spinal surgeries are susceptible to axial and/or rotational subsidence into the underlying vertebral bone. Experimental testing standards to examine implant subsidence, such as ASTM F2267, simplify the implant loading conditions and vertebral bone materials for ease of use and repeatability. Yet, the ability to assess clinically relevant risk of rotational subsidence with these methods is limited. Methods: The present work aimed to develop and evaluate a novel force‐control (FC) test method for performing unconstrained load‐induced implant subsidence into a heterogeneous material interface. The developed method was compared to the ASTM F2267 method, which uses a lubricated ball‐and‐socket joint, using the AMTI VIVO joint motion simulator to apply unconstrained loading up to 4 kN. Subsidence testing was performed on two different polyurethane (PU) foam densities (rigid 20 and 30 PCF) sandwiched together providing a heterogeneous boundary interface to induce implant rotation into the less dense foam. Results: Axial and rotational subsidence values varied significantly between the two test methods ( p < 0.05). Unconstrained axial compression up to 4 kN yielded, on average, 2.5 ± 0.4 mm of axial subsidence for ASTM‐based setup compared to 4.8 ± 0.6 mm for the FC setup. The ASTM‐based setup had an average implant rotation of 2.8° ± 0.5°, in contrast to the FC setup, with an average of 18.0° ± 0.9°. Additionally, the experimental FC results had good agreement with a computational finite element model of the same FC setup and PU foam materials. Conclusions: This new FC method for unconstrained load‐induced subsidence testing demonstrates potential improvements in consideration for rotational implant subsidence and the associated clinical burden in spinal surgery.
Open AccessEvaluation of a Force‐Control Experimental Method to Perform Unconstrained Load‐Induced Subsidence Testing of Spinal Interbody Implants
Introduction: Intervertebral body fusion devices (“interbody cages”) used in spinal surgeries are susceptible to axial and/or rotational subsidence into the underlying vertebral bone. Experimental testing standards to examine implant subsidence, such as ASTM F2267, simplify the implant loading conditions and vertebral bone materials for ease of use and repeatability. Yet, the ability to assess clinically relevant risk of rotational subsidence with these methods is limited. Methods: The present work aimed to develop and evaluate a novel force‐control (FC) test method for performing unconstrained load‐induced implant subsidence into a heterogeneous material interface. The developed method was compared to the ASTM F2267 method, which uses a lubricated ball‐and‐socket joint, using the AMTI VIVO joint motion simulator to apply unconstrained loading up to 4 kN. Subsidence testing was performed on two different polyurethane (PU) foam densities (rigid 20 and 30 PCF) sandwiched together providing a heterogeneous boundary interface to induce implant rotation into the less dense foam. Results: Axial and rotational subsidence values varied significantly between the two test methods ( p < 0.05). Unconstrained axial compression up to 4 kN yielded, on average, 2.5 ± 0.4 mm of axial subsidence for ASTM‐based setup compared to 4.8 ± 0.6 mm for the FC setup. The ASTM‐based setup had an average implant rotation of 2.8° ± 0.5°, in contrast to the FC setup, with an average of 18.0° ± 0.9°. Additionally, the experimental FC results had good agreement with a computational finite element model of the same FC setup and PU foam materials. Conclusions: This new FC method for unconstrained load‐induced subsidence testing demonstrates potential improvements in consideration for rotational implant subsidence and the associated clinical burden in spinal surgery.