Fluoroscopy-controlled voiding cystourethrography in infants and children: Are the radiation risks trivial?
- 3 December 2005
- journal article
- pediatric
- Published by Springer Nature in European Radiology
- Vol. 16 (4) , 846-851
Abstract
The purpose of this study was to determine the gonadal dose, effective dose and relevant radiogenic risks associated with pediatric patients undergoing voiding cystourethrography (VCUG). Exposure parameters were monitored in 118 consecutive children undergoing VCUG. The entrance surface dose (ESD) was determined by thermoluminescent dosimeters (TLDs). For male patients, the gonadal dose was determined by TLDs attached on the anterior scrotum. For female patients, the gonadal dose was estimated by converting ESD to the ovarian dose. ESD-to-ovarian dose conversion factors were determined by thermoluminescence dosimetry and physical anthropomorphic phantoms representing newborn and 1-, 5- and 10-year-old individuals. The effective dose was estimated by using ESD and data obtained from the literature. The mean fluoroscopy time and number of radiographs during VCUG were 0.73 min and 2.3 for female and 0.91 min and 3.0 for male pediatric patients, respectively. The gonadal dose range was 0.34–5.17 mGy in boys and 0.36–2.57 mGy in girls. The corresponding ranges of effective dosage were 0.12–1.67 mSv and 0.15–1.45 mSv. Mean radiation risks for genetic anomalies and carcinogenesis following VCUG during childhood were estimated to be up to 15 per million and 125 per million, respectively. Radiation risks associated with pediatric patients undergoing VCUG should not be disregarded if such a procedure is to be justified adequately.Keywords
This publication has 15 references indexed in Scilit:
- CT Voiding Cystourethrography Using 16-MDCT for the Evaluation of Female Urethral Diverticula: Initial ExperienceAmerican Journal of Roentgenology, 2005
- Radiation doses in pediatric radiology: influence of regulations and standardsPediatric Radiology, 2004
- Radiation protection dosimetry for diagnostic radiology patientsRadiation Protection Dosimetry, 2004
- Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinationsEuropean Radiology, 2003
- Radiation doses to paediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo studyBritish Journal of Radiology, 2003
- Lessons we have learned from our children: cancer risks from diagnostic radiologyPediatric Radiology, 2002
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- The radiation dose to children from X-ray examinations of the pelvis and the urinary tractBritish Journal of Radiology, 1995
- Results of a survey of doses to paediatric patients undergoing common radiological examinationsBritish Journal of Radiology, 1992
- Voiding cystourethrography in children: value of digital fluoroscopy in reducing radiation dose.American Journal of Roentgenology, 1992