Haemodynamic Changes of Interatrial Shunting Devices for Heart Failure: A Systematic Review and Meta-Analysis
Open Access
- 23 March 2022
- journal article
- review article
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (3) , 1987-1995
Abstract
Aims: To assess the efficacy and safety, primarily in relation to the haemodynamic effects, of interatrial shunting devices (ISD) for the treatment of heart failure (HF), we conducted a systematic review and a meta-analysis. Methods and results: We used the MEDLINE, Cochrane Library, Embase, and PubMed databases to identify clinical studies (published to 4 August 2021) that evaluated the effect of ISD on HF. The primary endpoint was defined as changes in pulmonary capillary wedge pressure (PCWP). Secondary endpoints included (i) other haemodynamic indexes, including cardiac output (CO), right atrial pressure (RAP), and mean pulmonary artery pressure (mPAP) by right heart catheterization, and (ii) change from baseline in 6 min walk distance (6MWD). After a literature search and detailed evaluation, six trials enrolling a total of 203 individuals were included in the quantitative analysis. Pooled analyses showed that after ISD implantation, PCWP decreased by a mean 3.10 mmHg [95% confidence interval (CI) −4.56 to −1.64; I2 = 0%; P < 0.0001]. Overall, CO increased by 0.77 L/min (95% CI 0.02 to 1.52; P = 0.04; I2 = 82%), but there were no significant changes in RAP or mPAP. The mean 6MWD increased by 32.33 m (95% CI 10.74 to 53.92; P = 0.003; I2 = 0) after ISD implantation. Conclusions: Interatrial shunting device can effectively reduce PCWP, increase CO and 6MWD, and has no obvious adverse effects on the right heart and pulmonary pressure. Studies with larger sample size and longer follow-up time are needed for further verification.Keywords
Funding Information
- National Key Research and Development Program of China (2021YFC2501106)
- National Key Research and Development Program of China (2021YFC2501106)
This publication has 33 references indexed in Scilit:
- Effects of an Interatrial Shunt on Rest and Exercise Hemodynamics: Results of a Computer Simulation in Heart FailureJournal of Cardiac Failure, 2014
- Cardiac Output Response to Exercise in Relation to Metabolic Demand in Heart Failure with Preserved Ejection FractionEuropean Journal of Heart Failure, 2013
- Incidence and epidemiology of new onset heart failure with preserved vs. reduced ejection fraction in a community-based cohort: 11-year follow-up of PREVENDEuropean Heart Journal, 2013
- Lutembacher's syndromeJournal of Cardiovascular Disease Research, 2012
- The Cochrane Collaboration's tool for assessing risk of bias in randomised trialsBMJ, 2011
- ESC Guidelines for the management of grown-up congenital heart disease (new version 2010): The Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Physician-Directed Patient Self-Management of Left Atrial Pressure in Advanced Chronic Heart FailureCirculation, 2010
- The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions: Explanation and ElaborationPLOS Medicine, 2009
- The 6 Minute Walking Test in Chronic Heart Failure: Indications, Interpretation and Limitations from a Review of the LiteratureEuropean Journal of Heart Failure, 2004
- Peak exercise cardiac power output; a direct indicator of cardiac function strongly predictive of prognosis in chronic heart failureEuropean Heart Journal, 2001