Nontoxic electron collimators
Open Access
- 4 September 2021
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (10) , 73-81
Abstract
Purpose The goal of this work was to develop and test nontoxic electron collimation technologies for clinical use. Methods Two novel technologies were investigated: tungsten-silicone composite and 3D printed electron cutouts. Transmission, dose uniformity, and profiles were measured for the tungsten-silicone. Surface dose, relative dose output, and field size were measured for the 3D printed cutouts and compared with the standard cerrobend cutouts in current clinical use. Quality assurance tests including mass measurements, Megavoltage (MV) imaging, and drop testing were developed for the 3D printed cutouts as a guide to safe clinical implementation. Results Dose profiles of the flexible tungsten-silicone skin shields had an 80–20 penumbra values of 2–3 mm compared to 7–8 mm for cerrobend. In MV transmission image measurements of the tungsten-silicone, 80% of the pixels had a transmission value within 2% of the mean. An ∼90% reduction in electron intensity was measured for 6 MeV and a 6.4 mm thickness of tungsten-silicone and 12.7 mm thickness for 16 MeV. The maximum difference in 3D printed cutout versus cerrobend output, surface dose, and full width at half-maximum (FWHM) was 1.7%, 1.2%, and 1.5%, respectively, for the 10 cm × 10 cm cutouts. Conclusions Both flexible tungsten-silicone and 3D printed cutouts were found to be feasible for clinical use. The flexible tungsten-silicone was of adequate density, flexibility, and uniformity to serve as skin shields for electron therapy. The 3D printed cutouts were dosimetrically equivalent to standard cerrobend cutouts and were robust enough for handling in the clinical environment.Keywords
This publication has 11 references indexed in Scilit:
- Dosimetric Characterization of a Novel Surface Collimator With Tungsten Functional Paper for Electron TherapyAnticancer Research, 2019
- The Shielding Ability of Novel Tungsten Rubber Against the Electron Beam for Clinical Use in Radiation TherapyAnticancer Research, 2018
- Low-cost optical scanner and 3-dimensional printing technology to create lead shielding for radiation therapy of facial skin cancer: First clinical case seriesAdvances in Radiation Oncology, 2018
- Technical Note: Fabricating Cerrobend grids with 3D printing for spatially modulated radiation therapy: A feasibility studyMedical Physics, 2015
- Lead toxicity: a reviewInterdisciplinary Toxicology, 2015
- Design and production of 3D printed bolus for electron radiation therapyJournal of Applied Clinical Medical Physics, 2014
- Multisource modeling of flattening filter free (FFF) beam and the optimization of model parametersMedical Physics, 2011
- Dosimetry of a prototype retractable eMLC for fixed-beam electron therapyMedical Physics, 2004
- Utilization of custom electron bolus in head and neck radiotherapyJournal of Applied Clinical Medical Physics, 2003
- Energy- and intensity-modulated electron beams for radiotherapyPhysics in Medicine & Biology, 2000