Abstract
A nuclear power plant (NPP) depends on instrumentation and control (I&C) systems to ensure its safe and efficient operation. In particular, I&C cables take on the pivotal role of measuring and controlling the critical equipment of the NPP. Thus, it is indubitable that the diagnostic technology of I&C cables for detecting faults and accurately assessing their health status is required for ensuring the safety and reliability of the NPP operation. We propose a diagnostic method that combines fault detection and evaluation algorithm for the I&C cables with stepped-frequency waveform reflectometry with signal propagation and reflection modeling. The signal modeling allows the assessment of the fault with an estimated reflection coefficient by separating the propagation and reflection effects of the measured signal. In short, cable faults are differentiated and quantified regardless of distance. The proposed algorithm is verified by characteristic impedance measurement, various fault detection/evaluation experiments, and the fault evaluation of local accelerated thermal aging cable.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2017R1A2A1A05001022)
- National Research Foundation of Korea through the Framework of International Cooperation Program (2016K2A9A1A03905116)
This publication has 23 references indexed in Scilit:
- Degradation of cable insulation material by accelerated thermal radiation combined ageingIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Condition Monitoring of Instrumentation Cable Splices Using Kalman FilteringIEEE Transactions on Instrumentation and Measurement, 2015
- Mechanical aging trend in ethylene propylene rubber-insulated safety cables sampled from bwr nuclear power containmentIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Cable condition monitoring for nuclear power plants2012
- Monitoring the moisture-related degradation of ethylene propylene rubber cable by electrical and SEM methodsPolymer Degradation and Stability, 2006
- Application of Time-Frequency Domain Reflectometry for Detection and Localization of a Fault on a Coaxial CableIEEE Transactions on Instrumentation and Measurement, 2005
- A Wigner approximation method for wave propagationThe Journal of the Acoustical Society of America, 2005
- Frequency-domain reflectometery for on-board testing of aging aircraft wiringIEEE Transactions on Electromagnetic Compatibility, 2003
- Pulse propagation in dispersive media2002
- An overview of polymer ageing studies in the nuclear power industryNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001